Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> <strong>Installation</strong><br />
OP16 Output Expander<br />
Output Module Layout<br />
Engineers<br />
Keypad<br />
Interface<br />
Bank 1<br />
Outputs<br />
1 to 8<br />
Tamper<br />
Switch<br />
Network<br />
Terminals<br />
Remote<br />
BANK 1<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Aux 12V<br />
and Tamper<br />
Output<br />
NETWORK IN<br />
Aux 12V NETWORK OUT<br />
+ - T R Tmp - - + + + - T R<br />
1 2 3 4<br />
BANK 1<br />
1 2 3 4<br />
BANK 2<br />
1Amp Aux 12v<br />
1<br />
Amp<br />
Power<br />
Network<br />
Terminals<br />
BANK 2<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Bank 2<br />
Outputs<br />
1 to 8<br />
Power LED<br />
Connecting Output Modules<br />
Output modules are connected to the network terminals<br />
located at the bottom left hand corner of the control panel<br />
(see pages 12 & 13 for details).<br />
Output Module Addressing<br />
Each output module must be assigned a different address<br />
using the DIL switches located in the centre of the PCB.<br />
The table below shows the expander addressing:<br />
Address DIL 1 DIL 2 DIL 3 DIL 4<br />
1 On or off Off Off Off 1 2 3 4<br />
2 Off On Off Off 2<br />
1 3 4<br />
3* Off Off On Off 1 2 3 4<br />
4* Off Off Off On 1 2 3 4<br />
5 ** On Off Off On 1 2 3 4<br />
6 ** Off On Off On 1 2 3 4<br />
7 ** Off Off On On<br />
8 ** On Off On On<br />
* <strong>Premier</strong> <strong>88</strong>, <strong>168</strong> and <strong>640</strong> only<br />
** <strong>Premier</strong> <strong>168</strong> and <strong>640</strong> only<br />
<br />
1 2 3 4<br />
1 2 3 4<br />
In order for an output module to mimic zone expander<br />
outputs, the output module must be addressed the<br />
same as the zone expander that it is mimicking.<br />
Any combination of addresses can be used on each<br />
output module i.e. Bank 1 can be addressed to mimic<br />
expander 3 and Bank 2 can be addressed to mimic<br />
expander 8.<br />
Bank 1 switch sets the address of the device that Bank<br />
1 outputs 1 to 8 will mimic.<br />
Bank 2 switch sets the address of the device that Bank<br />
2 outputs 1 to 8 will mimic.<br />
Output Module Numbering<br />
The table below shows the output allocation when the output<br />
modules are installed:<br />
Address<br />
Outputs<br />
(Network 1)<br />
Outputs<br />
(Network 2) **<br />
1 Expander 1, 1 - 8 Expander 1, 1 - 8<br />
2 Expander 2, 1 - 8 Expander 2, 1 - 8<br />
3 * Expander 3, 1 - 8 Expander 3, 1 - 8<br />
4 * Expander 4, 1 - 8 Expander 4, 1 - 8<br />
5 ** Expander 5, 1 - 8 Expander 5, 1 - 8<br />
6 ** Expander 6, 1 - 8 Expander 6, 1 - 8<br />
7 ** Expander 7, 1 - 8 Expander 7, 1 - 8<br />
8 ** Expander 8, 1 - 8 Expander 8, 1 - 8<br />
INS176 17<br />
<br />
Network 2 can only be used on the <strong>Premier</strong> <strong>168</strong>.<br />
For <strong>Premier</strong> <strong>640</strong> see page 18 for details<br />
* <strong>Premier</strong> <strong>88</strong>, <strong>168</strong> and <strong>640</strong> only<br />
** <strong>Premier</strong> <strong>168</strong> and <strong>640</strong> only<br />
Outputs<br />
The output module has 16 programmable outputs, which can<br />
be used to drive auxiliary devices such as LED’s, sounders or<br />
relays etc. Wire as per Panel Outputs shown on page 21 (see<br />
page 57 for details). The electrical characteristics for the<br />
outputs are shown below:<br />
Bank Outputs Max Current Type<br />
1 1 to 8 100mA Switched -ve<br />
2 1 to 8 100mA Switched -ve<br />
Tamper Output<br />
The tamper switch on the output module is connected to the<br />
tamper output at the top of the module. If monitoring of the lid<br />
tamper is required, this output must be connected to a<br />
suitable input on the control panel or zone expander.