<strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong> <strong>Installation</strong><br />

F1 - F5: Protection Fuses (<strong>Premier</strong> <strong>48</strong>, <strong>88</strong> and <strong>168</strong>)<br />

The following fuses are provided:<br />

• F1 (1Amp) Auxiliary 12V Power fuse<br />

• F2 (1.6 Amp) Battery fuse<br />

• F3 (1 Amp) Network 1 fuse<br />

• F4 (1 Amp) Bell/Strobe fuse<br />

• F5 (1 Amp) Network 2 fuse (<strong>Premier</strong> <strong>168</strong> only)<br />

F1 - F5: Protection Fuses (<strong>Premier</strong> <strong>640</strong>)<br />

The following electronic fuses are provided:<br />

• F3 (1600 mA) Battery<br />

• F4 (250mA) Speaker<br />

• F5 (900mA) Network 1<br />

• F6 (900mA) Bell/Strobe<br />

• F7 (900mA) Network 2<br />

• F8 (900mA) Network 3<br />

• F9 (900mA) Network 4<br />

• F10 (900mA) Network 5<br />

• F11 (900mA) Network 6<br />

• F12 (900mA) Network 7<br />

• F13 (900mA) Network 8<br />

• F14 (900mA) Auxiliary 12V<br />

Connecting AC Mains<br />

The AC Mains supply is connected to a 3 way ‘Euro Type’<br />

fused terminal block, which is fitted with a 125mA or 500mA<br />

fuse.<br />

INS176 11<br />

<br />

All other wiring MUST be carried out before AC mains<br />

is connected to the control panel.<br />

After connecting the AC Mains, fit the mains cover, this<br />

can be found in the spares bag.<br />

To transformer<br />

Connecting Batteries<br />

One or two 12V 7Ah batteries or one 12V 17Ah battery can be<br />

fitted inside the control panel to provide continued operation<br />

in the event of an AC mains failure.<br />

<br />

All other wiring MUST be carried out before the battery<br />

is connected to the control panel.<br />

Connect the red battery lead to the positive terminal of the<br />

battery and then connect the black battery lead to the<br />

negative terminal.<br />

<br />

The panel will only become ‘live’ when the AC Mains is<br />

connected or the ‘Battery Kick-start’ button is pressed.<br />

+<br />

12V 17Ah Battery<br />

-<br />

+<br />

12V 7Ah Battery<br />

-<br />

+<br />

12V 7Ah Battery<br />

-<br />

+<br />

12V 7Ah Battery<br />

-<br />

OR<br />

OR<br />

L<br />

E<br />

N<br />

+<br />

_<br />

Battery<br />

+<br />

_ Battery<br />

+<br />

_ Battery