Premier 48, 88, 168 & 640 Installation Manual - PVK
Premier 48, 88, 168 & 640 Installation Manual - PVK Premier 48, 88, 168 & 640 Installation Manual - PVK
Quick Reference Guide Premier 48, 88, 168 & 640 Installation Manual Global Options Speaker Tones PC Output Text Use to select a tone type, to turn the tone on/off, to accept Use to select an Output, to edit, - to select characters (press the required key the appropriate number of times), to accept Custom O/P Text Use to select an Output, to edit, - to select characters (press the required key the appropriate number of times), to accept Keypad Setup Areas Use - to select keypad, to select network, to edit, - to select an area, ( = all areas, = areas A – H and I –P), to accept Zone Mapping Press to edit, - to enter zone number, to accept, Repeat for 2nd Options zone Press to edit, to select an option, to change the option, to accept P = PA Enabled A = PA is Audible Volume Sounder Options F = Fire Enabled D = PA is Delayed F = Medical Enabled Q = Quick Arm On T = Tamper Enabled O = Info.LED>Output Press to edit, - to enter a value, to accept Press to edit, to select an option, to change the option, to accept F = Fire Tones Enabled E = Entry Tones Enabled A = Alarm Tones Enabled F = Fault Tones Enabled S = Service Tones Enabled X = Exit Tones Enabled C = Chime Tones Enabled K = Use Keypad Areas Areas Text Expander Setup Use - to select expander, to select network, to edit, - to select an area, ( = all areas, = areas A – H and I –P), to accept Press to edit text, - to select characters (press the required key the appropriate number of times), to accept . , ? ! 1 @ “ - M N O 6 Move Cursor A B C 2 P Q R S 7 Copy Text to Memory D E F 3 T U V 8 Paste Text from Memory G H I 4 W X Y Z 9 Auxiliary Input J K L 5 0 _ Press to edit, - to select an input type, to accept Not Used Silence Sounders Volume Sounder Options Auxiliary Tamper Global Omit Key Bell Tamper Local Omit Key Remote Reset PSU Fault Line Fault +ve Defer Auto Arming Line Fault +ve Press to edit, - to enter a value, to accept Press to edit, to select an option, to change the option, to accept F = Fire Tones Enabled E = Entry Tones Enabled A = Alarm Tones Enabled F = Fault Tones Enabled S = Service Tones Enabled X = Exit Tones Enabled C = Chime Tones Enabled Panel Outputs Digi Outputs Com? Channels RedCARE Pins Keypad Outputs Expander Outputs System Outputs Upper, Lower Case, Predictive Text & Numerical Use - to select an output, to edit, - to enter an output group, - to enter output type, to accept Use - to select device, to select network, to select an output, to edit, - to enter an output group, - to enter output type, to accept Custom Outputs Use to select output, - to select a switch, to edit, - to enter an output group, - to enter output type, to accept X-10 Outputs Use - to select an output, to edit, - to enter an output group, - to enter output type, - to enter House/device Number, to accept 102 INS176
Premier 48, 88, 168 & 640 Installation Manual Quick Reference Guide Key Output Group Outputs Types Not Used: Press to accept System: Use - to enter an output type or use to search, to accept 00: Phone Line Fault 16: Digi Successful 32: Custom 3 Stage A 01: Mains Power Off 17: Digi Active 33: Custom 3 Stage B 02: Aux Fuse Fault 18: UDL Lockout 34: Custom 3 Stage AB 03: Auxiliary Tamper 19: UDL Call Active 35: Custom 4 Stage A 04: Bell Tamper 20: UDL Enabled 36: Custom 4 Stage B 05: Panel Lid Tamper 21: Confirmed Alarm 37: Custom 4 Stage AB 06: Engineer Working 22: Custom 1 Stage A 38: Com 1 Fault 07: Confirm Devices 23: Custom 1 Stage B 39: Com 2 Fault 08: Service Required 24: Custom 1 Stage AB 40: Com 3 Fault 09: Bell Fuse Blown 25: Custom 2 Stage A 41: Com 1 No Signal 10: Battery Fault 26: Custom 2 Stage B 42: Com 2 No Signal 11: Battery Test On 27: Custom 2 Stage AB 43: Com 3 No Signal 12: Courtesy Light 28: Radio-Pad Failed 44: Coms Fault 13: System Open 29: Radio Successful 45: Radio Jamming 14: Fully Arm 30: No Radio Signal 46: Radio RX Tamper 15: Digi Failed 31: Radio-Pad Lost Area: Use - to enter an output type or use to search, - to select an area, ( = all areas, = areas A – H and I –P), to accept 00: Intruder Alarm 21: Armed 42: On Test 01: Guard 1 Alarm 22: Full Arm 43: Test Fail 02: Guard 2 Alarm 23: Part Armed 44: Internal Alarm 03: Entry Alarm 24: Part Arming 45: Auto Arming 04: Confirmed Alarm 25: Force Arm 46: Time Arming 05: 24Hr Audible 26: Force Arming 47: 1 st Code Entered 06: 24Hr Silent 27: Arm Fail 48: 2 nd Code Entered 07: 24Hr Gas 28: Bell SAB 49: Area Secured 08: PA Audible 29: Bell SCB 50: Part Armed 1 09: PA Silent 30: Strobe 51: Part Armed 2 10: Duress 31: Switch 12 Volts 52: Part Armed 3 11: Fire Alarm 32: Detector Reset 53: Custom Alarm 12: Medical 33: Walk Test Active 54: Zone Warning 13: Auxiliary Alarm 34: Zones Omitted 55: Arm Fail Warning 14: Tamper Alarm 35: 24Hr Zones Omit 56: Forced Entry 15: Alarm Abort 36: Reset Required 57: Zones Locked Out 16: Ready 37: Door Strike 58: All Armed 17: Entry Mode 38: Chime Mimic 59: Auto Arm Disable 18: 2 nd Entry Mode 39: Chime Enabled 60: Armed / Alarm 19: Exit Mode 40: DK First Knock 61: Intruder Alarm 20: Entry/Exit Mode 41: BP First Knock 62: Speaker Mimic Zone: Use - to enter a zone number or use to search, - to select a zone output type, to accept Mimic Alarm MimicLatch MimicArm Tamper Omitted User: Use - to select a User code or use to search, to accept Control Timer: Use - to select a Control Timer, to accept PC Control: Use - to select a PC Control, to accept Door Control: Use - to select a Door Control, to accept Key Attributes Attribute Types Attributes Press to edit, - to select attributes, to accept U = User Test 2 = Use Pulse Timer 2 I = Inverted 3 = Use Pulse Timer 3 L = Latch Until C = Custom Output 1, Stage A 1 = Use Pulse Timer 1 R = Random INS176 103
- Page 51 and 52: Premier 48, 88, 168 & 640 Installat
- Page 53 and 54: Premier 48, 88, 168 & 640 Installat
- Page 55 and 56: Premier 48, 88, 168 & 640 Installat
- Page 57 and 58: Premier 48, 88, 168 & 640 Installat
- Page 59 and 60: Premier 48, 88, 168 & 640 Installat
- Page 61 and 62: Premier 48, 88, 168 & 640 Installat
- Page 63 and 64: Premier 48, 88, 168 & 640 Installat
- Page 65 and 66: Premier 48, 88, 168 & 640 Installat
- Page 67 and 68: Premier 48, 88, 168 & 640 Installat
- Page 69 and 70: Premier 48, 88, 168 & 640 Installat
- Page 71 and 72: Premier 48, 88, 168 & 640 Installat
- Page 73 and 74: Premier 48, 88, 168 & 640 Installat
- Page 75 and 76: Premier 48, 88, 168 & 640 Installat
- Page 77 and 78: Premier 48, 88, 168 & 640 Installat
- Page 79 and 80: Premier 48, 88, 168 & 640 Installat
- Page 81 and 82: Premier 48, 88, 168 & 640 Installat
- Page 83 and 84: Premier 48, 88, 168 & 640 Installat
- Page 85 and 86: Premier 48, 88, 168 & 640 Installat
- Page 87 and 88: Premier 48, 88, 168 & 640 Installat
- Page 89 and 90: Premier 48, 88, 168 & 640 Installat
- Page 91 and 92: Premier 48, 88, 168 & 640 Installat
- Page 93 and 94: Premier 48, 88, 168 & 640 Installat
- Page 95 and 96: Premier 48, 88, 168 & 640 Installat
- Page 97 and 98: Premier 48, 88, 168 & 640 Installat
- Page 99 and 100: Premier 48, 88, 168 & 640 Installat
- Page 101: Premier 48, 88, 168 & 640 Installat
- Page 105 and 106: Premier 48, 88, 168 & 640 Installat
- Page 107 and 108: Premier 48, 88, 168 & 640 Installat
Quick Reference Guide <strong>Premier</strong> <strong>48</strong>, <strong>88</strong>, <strong>168</strong> & <strong>640</strong> <strong>Installation</strong> <strong>Manual</strong><br />
<br />
Global Options<br />
Speaker Tones<br />
PC Output Text<br />
Use to select a tone type, to turn the tone on/off, to accept<br />
Use to select an Output, to edit, - to select characters (press the required<br />
key the appropriate number of times), to accept<br />
Custom O/P Text Use to select an Output, to edit, - to select characters (press the required<br />
key the appropriate number of times), to accept<br />
<br />
Keypad Setup<br />
Areas<br />
Use - to select keypad, to select network, to edit, - to select<br />
an area, ( = all areas, = areas A – H and I –P), to accept<br />
Zone Mapping Press to edit, - to enter zone number, to accept, Repeat for 2nd Options<br />
zone<br />
Press to edit, to select an option, to change the option, to accept<br />
P = PA Enabled A = PA is Audible<br />
<br />
<br />
<br />
Volume<br />
Sounder Options<br />
F = Fire Enabled D = PA is Delayed<br />
F = Medical Enabled Q = Quick Arm On<br />
T = Tamper Enabled O = Info.LED>Output<br />
Press to edit, - to enter a value, to accept<br />
Press to edit, to select an option, to change the option, to accept<br />
F = Fire Tones Enabled E = Entry Tones Enabled<br />
<br />
<br />
<br />
<br />
<br />
<br />
A = Alarm Tones Enabled<br />
F = Fault Tones Enabled<br />
S = Service Tones Enabled<br />
X = Exit Tones Enabled<br />
C = Chime Tones Enabled<br />
K = Use Keypad Areas<br />
<br />
Areas<br />
Text<br />
Expander Setup<br />
Use - to select expander, to select network, to edit, - to select<br />
an area, ( = all areas, = areas A – H and I –P), to accept<br />
Press to edit text, - to select characters (press the required key the<br />
appropriate number of times), to accept<br />
. , ? ! 1 @ “ - M N O 6 Move Cursor<br />
A B C 2 P Q R S 7 Copy Text to Memory<br />
D E F 3 T U V 8 Paste Text from Memory<br />
G H I 4 W X Y Z 9 <br />
<br />
Auxiliary Input<br />
J K L 5 0 _<br />
Press to edit, - to select an input type, to accept<br />
Not Used Silence Sounders<br />
<br />
<br />
<br />
<br />
<br />
Volume<br />
Sounder Options<br />
Auxiliary Tamper Global Omit Key<br />
Bell Tamper Local Omit Key<br />
Remote Reset PSU Fault<br />
Line Fault +ve Defer Auto Arming<br />
Line Fault +ve<br />
Press to edit, - to enter a value, to accept<br />
Press to edit, to select an option, to change the option, to accept<br />
F = Fire Tones Enabled E = Entry Tones Enabled<br />
<br />
<br />
<br />
<br />
<br />
<br />
A = Alarm Tones Enabled<br />
F = Fault Tones Enabled<br />
S = Service Tones Enabled<br />
X = Exit Tones Enabled<br />
C = Chime Tones Enabled<br />
<br />
Panel Outputs<br />
Digi Outputs<br />
Com? Channels<br />
RedCARE Pins<br />
Keypad Outputs<br />
Expander Outputs<br />
System Outputs<br />
Upper, Lower Case, Predictive<br />
Text & Numerical<br />
Use - to select an output, to edit, - to enter an output group,<br />
- to enter output type, to accept<br />
Use - to select device, to select network, to select an output, to<br />
edit, - to enter an output group, - to enter output type, to accept<br />
Custom Outputs Use to select output, - to select a switch, to edit, - to enter an<br />
output group, - to enter output type, to accept<br />
X-10 Outputs Use - to select an output, to edit, - to enter an output group,<br />
- to enter output type, - to enter House/device Number, to accept<br />
102 INS176