CN6 Analog Input for Potentiometer<br />
Connector<br />
type<br />
TYCO CST100 3-Pol Wiring Harness: AMP MTA100 3-Pol<br />
Pin 1 L3V3 Logic +3.3V<br />
Pin 2 PA0 Analog IN<br />
Pin 3 LGND Logic Ground<br />
eigerScript eVM Command-Class: InOut<br />
InOut.Read_ADC( VarInt:Kanal_PA0 , VarInt:Value_0-1023 )<br />
Circuit examples<br />
Use of a potentiometer by the use of analog input PA0:<br />
Use of an NTC (e.g. as temperature sensor) by the use of analog input PA0:<br />
CN6A / CN6B BUS, Serial Interface RS485<br />
Matching cable: F4336<br />
Connector type Molex MiniFit jr. 5566 4-Pol Wiring Harness: Molex MiniFit jr. 5566 housing 4-Pol<br />
Pin 1 L12V Logic +12V<br />
Pin 2 RXTX- RS485 Line minus<br />
Pin 3 LGND Logic Ground<br />
Pin 4 RXTX+ RS485 Line plus<br />
Matching cable: F4368<br />
< Contents<br />
eigerScript eVM commands of class DataServer:<br />
DataServer.ReceiveToFile( VarInt:NodeAdress , VarStr:FileName )<br />
DataServer.ReceiveToString( VarInt:NodeAdress , VarStr:ZielString )<br />
DataServer.Rx_ReadInteger( VarInt:NodeAdress , VarInt:Register , VarInt:Value )<br />
DataServer.Rx_ReadLong( VarInt:NodeAdress , VarInt:Register , VarLong:Value )<br />
DataServer.Rx_String( VarInt:NodeAdress , VarInt:Register , VarLong:Value )<br />
DataServer.SendFromFile( VarInt:NodeAdress , VarStr:FileName )<br />
DataServer.SendFromString( VarInt:NodeAdress , VarStr:QuellString )<br />
DataServer.Tx_Command( VarInt:NodeAdress , VarInt:Register , VarInt:Command )<br />
DataServer.Tx_String( VarInt:NodeAdress , VarInt:Register , VarStr:String )<br />
DataServer.Tx_WriteInteger( VarInt:NodeAdress , VarInt:Register , VarInt:Value )<br />
DataServer.Tx_WriteLong( VarInt:NodeAdress , VarInt:Register , VarLong:Value )<br />
eigerScript eVM commands of class Debug:<br />
Debug.Mark( Str )<br />
Debug.DumpBytes( VarInt )<br />
Debug.Print_IntegerHex( Str , VarInt )<br />
Debug.Print_LongHex( Str , VarLong )<br />
Debug.Print_SingleHex( Str , VarSingle )<br />
Debug.Print_Char( VarInt )<br />
Debug.Print_CLRF( )<br />
Debug.Print_String( VarStr )<br />
Debug.Print_StringHeader( VarStr )<br />
< Contents<br />