Table 9. Description and Results <strong>of</strong> the C9 Simulation Scenarios.<br />

Scenario Heat Cooling Insolation Max Difference Cross<br />

Source Flange from Over<br />

– (W/m 2 ) Temp. ( ◦ F) (W/m 2 ) Temp. ( ◦ F ) C9SIM ( ◦ F ) (minutes)<br />

C9SIM – 40 – 466.40 – 00<br />

HSSIM1 80 40 – 441.90 24.5 550<br />

HSSIM2 120 40 – 452.86 13.54 230<br />

CTSIM1 80 100 – 443.32 23.08 275<br />

CTSIM2 120 120 – 443.80 22.60 265<br />

CTSIM3 120 120 – 454.77 11.63 168<br />

ISSIM1 80 100 143 444.16 22.24 235<br />

ISSIM2 80 100 300 445.11 21.29 200<br />

ISSIM3 120 120 300 456.59 9.81 140<br />

difference between the C9SIM and ISSIM3 scenarios is plotted in Figure 35 for both the<br />

shroud and flange temperatures. The results <strong>of</strong> the solar insolation analysis are consistent<br />

with the results <strong>of</strong> a two-dimensional axisymmetric finite element analysis performed by<br />

Ohashi and Ortega(8727) [4].<br />

The thermal conditions defining each <strong>of</strong> the scenarios and the maximum predicted flange<br />

temperature for each scenario are shown in Table 9. The table also reports the time at which<br />

the C9 thermal test is no longer able to adequately overestimate the flange temperature<br />

for each <strong>of</strong> the different scenarios, the cross over time. Since the cross over time for each<br />

<strong>of</strong> the scenarios is greater than the time the maximum flange temperature is reached (approximately<br />

90 minutes), the C9 thermal test provides a conservatively high estimate <strong>of</strong><br />

the maximum flange temperature in each scenario. This indicates that the pre-heating<br />

technique used in the various thermal tests is capable <strong>of</strong> taking into account the thermal<br />

effects present in a filled container. The results also show that as performed, the thermal<br />

tests provide a conservatively high estimate <strong>of</strong> the maximum flange temperature for several<br />

scenarios that meet or exceed the Federal regulations.<br />