In other words, PLOST,R is the same at any time of the day or year. Implicit<br />

in the assumption is that the same temperature profile is maintained on the receiver<br />

at all times and <strong>for</strong> any receiver size by adjusting the fluid flow rate, and<br />

that convective losses vary insignificantly with time.<br />

Letting ~RC,R,DP be the design point efficiency dased on receiver radiation and<br />

convection losses, then:<br />

qRC,R,DP =<br />

Pth,R - PLOST,R<br />

Pth,R<br />

=I---- QRAR<br />

Pth,R<br />

(1II.G - 10)<br />

where Pth,R = gross thermal power absorbed by the receiver at the design point.<br />

Similarly, let ~RC,R,AVG be the yearly average efficiency as calculated by:<br />

~RC,R,AVG =<br />

ETOT,R - (HOP x PLOST,R)<br />

ETOT,R<br />

=I- HOP x ~RAR<br />

ETOT, R<br />

where ETOT,R = total gross energy absorbed by the receiver per year<br />

Hop = total number of hours of receiver (not plant) operation.<br />

(1II.G - 11)<br />

CYR is determined from some reference design <strong>for</strong> which the radiation and con-<br />

vection losses have been calculated in more detail. Rearranging Equation (II1.G-<br />

10) ,<br />

(1II.G - 12)<br />

where the variables have the same meaning as above and the O superscript refers<br />

to the reference. Current default values depend on the type of receiver, but in<br />

all cases flow is from the bottom to the top of the receiver, molten salt flow is<br />

assumed, and q&-.R should be calculated based on the average ambient conditions<br />

(wind speed, temperature, etc.).<br />

82<br />

Defaults <strong>for</strong> an external receiver (cylindrical or flat plate) are<br />

q&R (REFRC) zz 0.83<br />

P:h,R (REFTHP) = 4.10 X IO8 watts