the j j axis from a minimum of FZMIN meters to a maximum of FZMAX meters,<br />
with respect to the point (XFC, YFC, ZFC).<br />
If IFLAUT=4, the flux points will be automatically located by the code on<br />
the assumed heat absorbing surface of the receiver. For this calculation, the cav-<br />
ity heat absorber height will always be assumed to be that value specified by H<br />
(namelist REC). The default choices <strong>for</strong> NXFLX, FAZMIN, FAZMAX, NYFLX,<br />
FZMIN, and FZMAX will result in a single point on the center of the north fac-<br />
ing heat absorbing surface. Essentially, <strong>for</strong> this option the code chooses the “cor-<br />
rect” values of DIAMF, XFC, YFC, ZFC, POLF, and AZMF, and then selects<br />
the appropriate option (IFLAUT=l, 2, or 3) <strong>for</strong> an external, cavity, or flat plate<br />
receiver, respectively. For this case, as <strong>for</strong> the first three options, the desired val-<br />
ues <strong>for</strong> NXFLX, FAZMIN, FAZMAX, NYFLX, FZMIN, and FZMAX should be<br />
specified. Also, if the surface to be examined <strong>for</strong> fluxes is not on the code-defined<br />
heat absorbing surface (e.g., examining flux at the aperture of a cavity receiver),<br />
then this option cannot be used, and one of the first three options should be used<br />
instead.<br />
II. G-2. Muz Constrained System Designs-Many receiver designs have flux<br />
limitations imposed on the heat absorbing surface to meet lifetime require-<br />
ments. DELSOL provides the option during the optimization procedure to de-<br />
sign systems with a peak flux constraint. The flux at NFLXMX points, where<br />
NFLXMX