01.03.2013 Views

A User's Manual for DELSOL3 - prod.sandia.gov - Sandia National ...

A User's Manual for DELSOL3 - prod.sandia.gov - Sandia National ...

A User's Manual for DELSOL3 - prod.sandia.gov - Sandia National ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NAZM = 12<br />

AMAXN = 82.5"<br />

11.23-2 Field Options-The number of heliostat zones is based on the specifi-<br />

cations of NRAD and NAZM. For design and optimization runs, a circular field<br />

of zones is required, although the field can be a surround (INORTH=O) or north<br />

(INORTII-1) field. In this case, NRAD remains constant around the circumfer-<br />

ence. For a per<strong>for</strong>mance run, it is possible to define a non-circular zonal configu-<br />

ration by specifying IUSERF=l.<br />

Although a heliostat field must be contained within the heliostat zone con-<br />

figuration chosen, the field does not have to occupy every zone. The variable<br />

IUSERF (namelist FIELD) in general is used to determine the relationship be-<br />

tween the heliostat zone pattern and the actual heliostat field layout that deter-<br />

mines field per<strong>for</strong>mance, as follows:<br />

a) IUSERF=O<br />

The user specifies RADMIN, RADMAX, NRAD, NAZM, and INORTH. No<br />

field boundaries are provided with this option, so the field boundaries are as-<br />

sumed to be the zone configuration boundaries. The code calculates and reports<br />

only the zone by zone per<strong>for</strong>mance <strong>for</strong> the symmetric grid defined by the five in-<br />

put variables above. Average field per<strong>for</strong>mance is meaningless in this case and<br />

there<strong>for</strong>e is not calculated. This option must be used <strong>for</strong> any initial per<strong>for</strong>mance<br />

run which will be used later <strong>for</strong> a field buildup (optimization) run. The best<br />

guess receiver and tower dimensions should be specified in conjunction with us-<br />

ing this option.<br />

6) IUSERF=I<br />

The code defined north biased surround field of Figure 11-6 is used. User spec-<br />

ifications of the field variables RADMIN, RADMAX, NRAD, NAZM, INORTH,<br />

NRADMN, and NRADMX are ignored. That is, the zonal configuration cannot<br />

be changed from that of Figure 11-6. The layout is typical of fields required <strong>for</strong><br />

larger industrial or electrical power plants (greater than about 250 MWth or 100<br />

M We, from Reference 9). Field averaged per<strong>for</strong>mance is calculated and reported.<br />

This option can only be used <strong>for</strong> an independent per<strong>for</strong>mance run in which the<br />

field is defined by the user with the variables DENSIT, AZMSEP, and FLAND.<br />

This option should not be used during a per<strong>for</strong>mance rerun of a system which has<br />

been previously optimized by DELSOL. The best guess receiver and tower dimen-<br />

sions should be specified in conjunction with using this option.<br />

c) IUSER F=Z<br />

This option allows the user to define a field zone by zone. The field definition<br />

can be specified directly by the user in a per<strong>for</strong>mance calculation or can be ob-<br />

tained from the results of a DELSOL optimization during a per<strong>for</strong>mance rerun.<br />

33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!