NAZM = 12<br />
AMAXN = 82.5"<br />
11.23-2 Field Options-The number of heliostat zones is based on the specifi-<br />
cations of NRAD and NAZM. For design and optimization runs, a circular field<br />
of zones is required, although the field can be a surround (INORTH=O) or north<br />
(INORTII-1) field. In this case, NRAD remains constant around the circumfer-<br />
ence. For a per<strong>for</strong>mance run, it is possible to define a non-circular zonal configu-<br />
ration by specifying IUSERF=l.<br />
Although a heliostat field must be contained within the heliostat zone con-<br />
figuration chosen, the field does not have to occupy every zone. The variable<br />
IUSERF (namelist FIELD) in general is used to determine the relationship be-<br />
tween the heliostat zone pattern and the actual heliostat field layout that deter-<br />
mines field per<strong>for</strong>mance, as follows:<br />
a) IUSERF=O<br />
The user specifies RADMIN, RADMAX, NRAD, NAZM, and INORTH. No<br />
field boundaries are provided with this option, so the field boundaries are as-<br />
sumed to be the zone configuration boundaries. The code calculates and reports<br />
only the zone by zone per<strong>for</strong>mance <strong>for</strong> the symmetric grid defined by the five in-<br />
put variables above. Average field per<strong>for</strong>mance is meaningless in this case and<br />
there<strong>for</strong>e is not calculated. This option must be used <strong>for</strong> any initial per<strong>for</strong>mance<br />
run which will be used later <strong>for</strong> a field buildup (optimization) run. The best<br />
guess receiver and tower dimensions should be specified in conjunction with us-<br />
ing this option.<br />
6) IUSERF=I<br />
The code defined north biased surround field of Figure 11-6 is used. User spec-<br />
ifications of the field variables RADMIN, RADMAX, NRAD, NAZM, INORTH,<br />
NRADMN, and NRADMX are ignored. That is, the zonal configuration cannot<br />
be changed from that of Figure 11-6. The layout is typical of fields required <strong>for</strong><br />
larger industrial or electrical power plants (greater than about 250 MWth or 100<br />
M We, from Reference 9). Field averaged per<strong>for</strong>mance is calculated and reported.<br />
This option can only be used <strong>for</strong> an independent per<strong>for</strong>mance run in which the<br />
field is defined by the user with the variables DENSIT, AZMSEP, and FLAND.<br />
This option should not be used during a per<strong>for</strong>mance rerun of a system which has<br />
been previously optimized by DELSOL. The best guess receiver and tower dimen-<br />
sions should be specified in conjunction with using this option.<br />
c) IUSER F=Z<br />
This option allows the user to define a field zone by zone. The field definition<br />
can be specified directly by the user in a per<strong>for</strong>mance calculation or can be ob-<br />
tained from the results of a DELSOL optimization during a per<strong>for</strong>mance rerun.<br />