value of insolation from the specified insolation model. If the values were signif-<br />

icantly different, the user might want to redesign his systems using a modified<br />

value of REFSOL.<br />

Close examination of the flux map reveals that peak flux does not occur at<br />

the north center of this receiver. What happened is that, because of the dis-<br />

crete steps in receiver size which were taken in designing the receiver, the height<br />

of this receiver is too large. Thus, heliostats were aimed to spread out the flux<br />

and mostly ended up being aimed not at the center of the receiver. However,<br />

if a more optimum receiver were designed by using a finer grid of size variables,<br />

the peak flux would be shifted back to the north center point of the receiver and<br />

would come much closer to meeting the allowable flux level.<br />