APPENDIX B-SAMPLE INPUT AND OUTPUT<br />

The following pages discuss DELSOL sample problems which illustrate many<br />

of the features of the code and provide example input <strong>for</strong>mats <strong>for</strong> the most com-<br />

mon types of problems. The related output listings, as generated on a CRAY<br />

computer, are attached in microfiche version in the back of this manual.<br />

Sample Problem la - Optimization of an External Receiver Design<br />

Problem Statement<br />

The optimum external molten salt receiver design at power levels of 75 to 150<br />

MWe with no storage is desired. An incident flux level of 0.85 MW/m2 is not<br />

to be exceeded anywhere on the receiver. The initial per<strong>for</strong>mance data should<br />

be saved <strong>for</strong> subsequent calculations, and the optimized field layouts should be<br />

printed. The optimized design and field layout <strong>for</strong> a power level of 125 MWe<br />

should be saved <strong>for</strong> a separate per<strong>for</strong>mance rerun.<br />

Input Cards<br />

SAMPLE PROBLEM la<br />

$BASIC IPROB-4. ITAPE=l $<br />

$FIELD S<br />

$HSTAT 3<br />

SREC 8<br />

$NLFLUX S<br />

SNLEFF $<br />

SREC IAUTOP=l f<br />

$OPT NUMTHT=B, THTST=100., THTEND=200.. NUMREC=6. WST=8.. WEND=18..<br />

NlJMHTW=J. HTWST=I.O. HTWEND=Z.O. NUMOPT=4, POPTMN=75.E+06.<br />

POPTMX=i50.€+06, SMULT=I.O. IPLFL=4*I. IOTAPE=I $<br />

$NLFLUX IFLX=l, FLXLIM=O.E5E+OG $<br />

SNLEFF SMULT=l.O $<br />

$NLCOST $<br />

SNLECON $<br />

SREC W=-1. f<br />

Analvsis of Input<br />

For any initial per<strong>for</strong>mance calculation in a design/optimization run<br />

IPROB=4 must be specified. The results of this initial per<strong>for</strong>mance run are saved<br />

on a file on Unit 10 by setting ITAPE=l. It is assumed that the solar subsystems<br />

are the same technology as specified by the default values in the code, and so no<br />

changes are necessary <strong>for</strong> the remaining per<strong>for</strong>mance input. Flux calculations and<br />

automatic aiming should not be done <strong>for</strong> an initial per<strong>for</strong>mance calculation.<br />