Reheater:<br />

CRHREF<br />

ARHREF<br />

PRHREF<br />

ARHMAX<br />

XHEA<br />

CEGREF<br />

PEGREF<br />

XEPGS<br />

CFIXED<br />

ICKN<br />

APH' = APH/NrH<br />

and similarly <strong>for</strong> the other heat exchangers. CPHREF ($)<br />

is the cost of a preheater of reference surface area<br />

and thermal power rating PPHREF (watts),<br />

the others. APHMAX is the maximum<br />

practical size preheater, etc.<br />

Default: CPHREF = 0.0 (;.e., no preheater in default<br />

APHREF = 1.0 case)<br />

PPHREF = 1.0<br />

APHMAX : 10"'<br />

CEVREF = 3.77~10' ($)<br />

AEVREF =Z 1300.0 (m2)<br />

PEVREF = 2 .6~10~ (watts)<br />

AEVMAX = 10"' (m2) (i.e., no size limit)<br />

CSHHEF = 1 .24~10~ ($)<br />

ASHREF - 400.0 (m2)<br />

PSIJREF = 2 .6~10~ (watts)<br />

ASHMAX = 10"' (ma)<br />

CRHREF = 1.38~10~ ($)<br />

ARIIREF 7- 310.0 (m2)<br />

PRHREF = 2 .6~10~ (watts)<br />

ARHMAX -: 10'" (ma)<br />

XHEA =- 0.6 (V . A- 10)<br />

EPGS cost parameters; CEPGS, total EPGS subsystem cost<br />

in $, given by:<br />

CEPGS = CEGREF' (PTH*ETAREF/PEGREF)X"P''s<br />

where PEGREF is the nameplate rating (watts <strong>for</strong> the<br />

reference turbine-generator costing CEGREF ( I ). ETAREF,<br />

the design thermal-electric conversion efficiency, is defined<br />

in namelist NLEFF.<br />

Default: CEGREF = 37.5~10' ($)<br />

PEGREF = 1.12~10~ (watts)<br />

XEPGS ~ 0 . 8 (V.A-11)<br />

Fixed costs associated with all plants independent of<br />

power level (master control, buildings and roads, etc.).<br />

This variable should be used only <strong>for</strong> unusual fixed costs,<br />

since other fixed costs are also included based on direct<br />

capital costs and power levels.<br />

Default: CFIXED = 0.0 ($) (V .A- 12)<br />

Flag <strong>for</strong> including a sodium-to-salt heat exchanger:<br />

= 0, component is not included<br />

= 1, component is included.<br />

Default: ICKN = 0 (V .A-9)