SMULT<br />

IPLFL(1)<br />

(I=l ,NUMOPT)<br />

IPROPT<br />

IHOPTP<br />

IOTAPE<br />

198<br />

rectangle relative to the center of the first<br />

rectangle. ALP(1) is the angle in degrees<br />

that the Ith rectangle is rotated about its<br />

center from the N-S, E-W orientation (positive<br />

angles represent a clockwise rotation when<br />

viewed from above). SLEW(1) and SLNS I) are<br />

the lengths of the sides of the Ith rectang i e<br />

that, prior to rotation by ALP(I), were<br />

parallel to the E-W and N-S axes, respectively.<br />

Constraint: NLAND 5 5<br />

Default: NLAND = 0<br />

ALP, CLE, CLN, SLEW, SLNS = 0<br />

(II.B-4,IV.C-4)<br />

Solar multiple at design point; l/SMULT of the thermal<br />

power at the base of the tower goes directly to the<br />

industrial or electrical process at the design point; the<br />

remainder is sent to storage. This variable should be<br />

consistently defined in Namelist NLEFF.<br />

Constraint: SMULT 2 1.0<br />

Default: SMULT = 1.5 (1V.C-5,VI)<br />

Parameter identifying the subset of the NUMOPT power<br />

levels at which field layouts are printed and descriptions<br />

of optimized system are written on Unit 30 if desired:<br />

= 0, no field layout output <strong>for</strong> the Ith power level;<br />

= 1, output generated <strong>for</strong> Ith power level.<br />

Constraint: Maximum number of nonzero IPLFL's = 5<br />

Default: IPLFL = 20'0<br />

(VI. A- 5)<br />

Parameter <strong>for</strong> detailed output of zone by zone field buildup<br />

(IPROPT = -1 is strongly recommended):<br />

= 0, output suppressed;<br />

= 1, output printed. (Note: this option generates a<br />

large amount of output);<br />

= - 1, limited output printed during optimization.<br />

Shows some detail of search and provides useful<br />

output even when program runs out of time.<br />

Default: IPROPT = -1<br />

Parameter <strong>for</strong> detailed print out of heliostat density<br />

optimization :<br />

= 0, output suppressed<br />

= I, output printed (Note: this option generates<br />

a large amount of output).<br />

Default: IHOPTP = 0<br />

Parameter specifying if user desires to write the results<br />

of an optimization run on Unit 30 to save as a permanent file,<br />

or to rerun <strong>for</strong> a detailed per<strong>for</strong>mance calculation, or both: