RYTRX<br />

RX2TRX<br />

RXSTRX<br />

RX4TRX<br />

NUMOPT<br />

POPTMN<br />

POPTMX<br />

NUMPOS<br />

XTPST<br />

YTPST<br />

XTPEND<br />

YTPEND<br />

NLAND<br />

ratios of the cavity apertures.<br />

constant. This option is<br />

cavity receiver.<br />

Constraints: HTWST 5 HTWEND<br />

1 5 NUMHTW 5 20<br />

Default: NUMHTW = 1<br />

HTWST =: 1.0<br />

HTWEND = 1.0<br />

IOPTUM = 1 (II.E,IV.C-3,1V.E)<br />

Cavity and flat plate receivers: RYTRX is the ratio<br />

RY(I)/RX(I), assumed the same <strong>for</strong> all apertures or flat<br />

plates. RXZTRX is the ratio RX(Z)/RX(l), etc. (See REC<br />

namelist <strong>for</strong> definitions of RX’s and RY’s.)<br />

Default: RYTRX - 1.0<br />

RX2TRX 7 1.0<br />

RX3TRX = 1.0<br />

RX4TRX =- 1.0 (II.E,IV.C-3)<br />

NIJMOPT equally spaced net electrical design power levels<br />

from POPTMN to POPTMX (in watts) considered <strong>for</strong> optimal<br />

design.<br />

constraint: 1 5 NUMOPT 5 20<br />

POPTMN 5 POPTMX<br />

Cost models not necessarily accurate<br />

below - 10’ watts.<br />

Default: NIJMOPT 7 20<br />

POPTMN = 2.0~10’ (watts)<br />

POPTMX = 4 .0~ lo8 (watts) (1V.B-l,IV.C-1)<br />

In a land constrained design (NLAND > 0, below) NUMPOS<br />

discrete, equally spaced values of the tower location#<br />

relative to the origin used to describe the land constraints<br />

are tested. The tower positions lie along a line<br />

specified by the coordinates of the first tower position<br />

(XTPST m east, YTPST m north) and the last tower<br />

position (XTPEND m east, YTPEND m north).<br />

Constraint: 1 5 NUMPOS 5 20<br />

Default: NUMPOS = 1<br />

XTPST = XTPEND = YTPST = YTPEND = 0.0<br />

( 11. B-4 ,IV . C-4, IV . E)<br />

Land constrained field parameters.<br />

NLAND = 0 No land constraint<br />

> 0 The land available <strong>for</strong> the heliostat at<br />

field is constrained to be within NLAND<br />

rectangles. CLE(1) and CLN(1) are the<br />

displacements in m to the east and north,<br />

respectively, of the center of the Ith