Design point parasitic load, expressed as a fraction<br />

of the gross electrical output.<br />

Default: REFPRL = 0.103 (III.G-6,11I.G-8)<br />

Fraction of design point parasitic load required <strong>for</strong><br />

operation from storage.<br />

Default: FSP = 0.66 (III.G-G,III.G-8)<br />

Fraction of design point parasitic load <strong>for</strong> operation<br />

electrical generating pumps (feedwater pumps, cooling<br />

tower, etc.).<br />

Default: FEP = 0.0 (III.G-G,III.G-8)<br />

Round trip efficiency through storage.<br />

Default: EFFSTR = 1.0 (1II.G-7)<br />

Plant factor; expected fraction of the year in which<br />

the plant will be on line. In a realistic<br />

calculation of busbar energy cost, PF should be some<br />

value less than 1.0.<br />

Default: PF = 0.90 ( III.G-8,III.H,IV.B-2)<br />

Solar multiple at design point; I/SMULT of the thermal<br />

power at the base of the tower goes directly to the<br />

industrial or electrical process at the design point; the<br />

rest is sent to storage. This variable should also be<br />

defined in Namelist OPT.<br />

Constraint: SMULT 2 1.0<br />

Default: SMULT = 1.5 (1V.C-5,VI)<br />

Parameter identifying industrial process heat run instead<br />

of electrical plant run:<br />

= 0, electrical plant; output in MW,, mills/kw-hr, etc.<br />

# 0, industrial process heat; code automatlcally sets<br />

ETAREF=1.0, FEFF=1.0, REFPRL=O.O, CEGREF=O.O.<br />

Default: IPH = 0 (1II.G-6,V.A-11)<br />

Coefficients <strong>for</strong> calculating thermal losses based on<br />

receiver area. REFRCl is related to radiative losses,<br />

the rest to convective losses.<br />

Constraint: IRADFL = 0, IRECO) REFRC 1= 16403.0<br />

REFRC2=7631.0<br />

REFRC2~5077.0 (1II.G-3)