REFPRL<br />
FSP<br />
FEP<br />
EFFSTR<br />
PF<br />
SMULT<br />
IP H<br />
REFRCl<br />
REFRCZ<br />
REFRC3<br />
194<br />
Design point parasitic load, expressed as a fraction<br />
of the gross electrical output.<br />
Default: REFPRL = 0.103 (III.G-6,11I.G-8)<br />
Fraction of design point parasitic load required <strong>for</strong><br />
operation from storage.<br />
Default: FSP = 0.66 (III.G-G,III.G-8)<br />
Fraction of design point parasitic load <strong>for</strong> operation<br />
electrical generating pumps (feedwater pumps, cooling<br />
tower, etc.).<br />
Default: FEP = 0.0 (III.G-G,III.G-8)<br />
Round trip efficiency through storage.<br />
Default: EFFSTR = 1.0 (1II.G-7)<br />
Plant factor; expected fraction of the year in which<br />
the plant will be on line. In a realistic<br />
calculation of busbar energy cost, PF should be some<br />
value less than 1.0.<br />
Default: PF = 0.90 ( III.G-8,III.H,IV.B-2)<br />
Solar multiple at design point; I/SMULT of the thermal<br />
power at the base of the tower goes directly to the<br />
industrial or electrical process at the design point; the<br />
rest is sent to storage. This variable should also be<br />
defined in Namelist OPT.<br />
Constraint: SMULT 2 1.0<br />
Default: SMULT = 1.5 (1V.C-5,VI)<br />
Parameter identifying industrial process heat run instead<br />
of electrical plant run:<br />
= 0, electrical plant; output in MW,, mills/kw-hr, etc.<br />
# 0, industrial process heat; code automatlcally sets<br />
ETAREF=1.0, FEFF=1.0, REFPRL=O.O, CEGREF=O.O.<br />
Default: IPH = 0 (1II.G-6,V.A-11)<br />
Coefficients <strong>for</strong> calculating thermal losses based on<br />
receiver area. REFRCl is related to radiative losses,<br />
the rest to convective losses.<br />
Constraint: IRADFL = 0, IRECO) REFRC 1= 16403.0<br />
REFRC2=7631.0<br />
REFRC2~5077.0 (1II.G-3)