REFTHP<br />
AREF<br />
REFRC<br />
REFLP<br />
REFPIP<br />
FPLH<br />
FPLC<br />
ITHEL<br />
ETAREF<br />
FEFF<br />
Namelist NLEFF<br />
Gross thermal power (watts) absorbed by a reference<br />
receiver (area AREF) be<strong>for</strong>e receiver and piping radiation<br />
and convection losses.<br />
Constraint: Data should be <strong>for</strong> same type receiver (;.e.,<br />
external, cavity, etc.) as in REC namelist.<br />
Default: REFTHP = 4.10~ 10' (watts) (IREC=0,3,4)<br />
REFTHP = 2.10~ 10' (watts) (IREC=1,2)<br />
(1II.G-3)<br />
Reference receiver area (m2); <strong>for</strong> cavities, this<br />
should be total aperture area.<br />
Default: AREF = 2780.0 (m2) (IREC=0,3,4)<br />
AREF = 761.0 (m') .(IREC=1,2 [I11 . G- 3)<br />
Fraction of REFTHP transferred to receiver working<br />
fluid after radiation and convection losses.<br />
Default: REFRC = 0.83 (1II.G-3)<br />
Reference pipe length (m) <strong>for</strong> calculating piping<br />
insulation losses.<br />
Default: REFLP = 170.0 (m) (1II.G-4)<br />
Fraction of REFRC' REFTHP delivered to storage and<br />
EPGS after piping losses.<br />
Default: REFPIP = 0.99 (1II.G-4)<br />
Factor multiplying tower height to give total hot<br />
piping run in a single module.<br />
Default: FPLH = 2.6 (III.G-4,V.A-7)<br />
Factor multiplying tower height to give total cold piping<br />
run in a single module (may be different from FPLH if<br />
expansion allowance different).<br />
Default: FPLC = 2.6 (V.A-7)<br />
Parameter <strong>for</strong> design point thermal/electric conversion<br />
efficiency:<br />
= 0, efficiency assumed constant at all<br />
design power levels, value<br />
specified by ETAREF;<br />
# 0, efficiency varies with design power<br />
level as described in Figure 111-3.<br />
Default: ITHEL r= 0 (1II.G-5,111.G-6)<br />
Design point thermal/electric conversion efficiency;<br />
constant at all power levels (only used when ITHEL = 0).<br />
Default: ETAREF = 0.42 (III.G-5,III.H,V.A-11)<br />
Fraction of design point efficiency describing average .<br />
off-design operation. i<br />
Default: FEFF = 0.90 (III.G-5,III.G-G,III.H)<br />
193