REFTHP<br />

AREF<br />

REFRC<br />

REFLP<br />

REFPIP<br />

FPLH<br />

FPLC<br />

ITHEL<br />

ETAREF<br />

FEFF<br />

Namelist NLEFF<br />

Gross thermal power (watts) absorbed by a reference<br />

receiver (area AREF) be<strong>for</strong>e receiver and piping radiation<br />

and convection losses.<br />

Constraint: Data should be <strong>for</strong> same type receiver (;.e.,<br />

external, cavity, etc.) as in REC namelist.<br />

Default: REFTHP = 4.10~ 10' (watts) (IREC=0,3,4)<br />

REFTHP = 2.10~ 10' (watts) (IREC=1,2)<br />

(1II.G-3)<br />

Reference receiver area (m2); <strong>for</strong> cavities, this<br />

should be total aperture area.<br />

Default: AREF = 2780.0 (m2) (IREC=0,3,4)<br />

AREF = 761.0 (m') .(IREC=1,2 [I11 . G- 3)<br />

Fraction of REFTHP transferred to receiver working<br />

fluid after radiation and convection losses.<br />

Default: REFRC = 0.83 (1II.G-3)<br />

Reference pipe length (m) <strong>for</strong> calculating piping<br />

insulation losses.<br />

Default: REFLP = 170.0 (m) (1II.G-4)<br />

Fraction of REFRC' REFTHP delivered to storage and<br />

EPGS after piping losses.<br />

Default: REFPIP = 0.99 (1II.G-4)<br />

Factor multiplying tower height to give total hot<br />

piping run in a single module.<br />

Default: FPLH = 2.6 (III.G-4,V.A-7)<br />

Factor multiplying tower height to give total cold piping<br />

run in a single module (may be different from FPLH if<br />

expansion allowance different).<br />

Default: FPLC = 2.6 (V.A-7)<br />

Parameter <strong>for</strong> design point thermal/electric conversion<br />

efficiency:<br />

= 0, efficiency assumed constant at all<br />

design power levels, value<br />

specified by ETAREF;<br />

# 0, efficiency varies with design power<br />

level as described in Figure 111-3.<br />

Default: ITHEL r= 0 (1II.G-5,111.G-6)<br />

Design point thermal/electric conversion efficiency;<br />

constant at all power levels (only used when ITHEL = 0).<br />

Default: ETAREF = 0.42 (III.G-5,III.H,V.A-11)<br />

Fraction of design point efficiency describing average .<br />

off-design operation. i<br />

Default: FEFF = 0.90 (III.G-5,III.G-G,III.H)<br />

193