NMXFLXY)<br />

identifies the exact point to be evaluated.<br />

as follows see Figure 11-16).<br />

If M = azimuthal location between 1 and NXFLX<br />

N = vertical location between 1 and NYFLX<br />

then NMXFLX(1) = M + (N-1)'NXFLX<br />

Constraints: NFLXMX 5 4<br />

NFLXMX 5 NXFLX*NYFLX<br />

NMXFLX(1) 5 NXFLX*NYFLX<br />

Default: NFLXMX = 1<br />

NMXFLX(1) = I (I=1,4) (1I.G-2,1V.D-1)<br />

FLXLIM( I)<br />

Maximum allowed flux on the receiver in W/m2 at<br />

(I=l,NFLXMX) NMXFLX( I) flux point.<br />

Default:<br />

= l.OE+lO<br />

(1I.G-2,1V.D- 1)<br />

192