This option should be used with external<br />

cylinder, elliptical flat plate and elliptical<br />

aperture cavity receivers with flux limits<br />

(Namelist NLFLUX);<br />

= 2, same as 1 except that the images are spread<br />

out in 2-d. This option should be used only<br />

with rectangular flat plate or rectangular<br />

aperture receivers with flux limits;<br />

= 3, time dependent aiming strategy to reduce<br />

radiation/convection losses, to reduce thermalmechanical<br />

damage, or to minimize the size of<br />

a heat absorbing surface inside a cavity. For<br />

each zone the image is centered across the<br />

“width” of the receiver or aperture and is<br />

positioned as close to the bottom of the<br />

receiver as possible without increasing<br />

spillage significantly;<br />

= 4, same as 3 except the images are spread out<br />

along the width of the receiver. This option<br />

should only be used with a rectangular flat<br />

plate or rectangular aperture receiver;<br />

= 5, user defined, time independent, uni<strong>for</strong>m<br />

aiming. For the (K,L) zone the aim points are<br />

arranged in a rectangular grid that is in the<br />

plane of the cavity aperture or flat plate or<br />

is in the plane that is tangent to the external<br />

receiver at the azimuthal angle of the zone<br />

There are NAX(K,L) aim points along the<br />

horizontal direction from a minimum value of<br />

XAIM K,L,1 meters to a maximum value of<br />

XAIM t l<br />

K,L,2 meters. Similarly, there are<br />

NAY(K,L) aim points along the “vertical”<br />

direction from a minimum value of YAIM(K,L,l)<br />

meters to a maximum value of YAIM(K,L,2)<br />

meters. Note that this option should only be<br />

used <strong>for</strong> per<strong>for</strong>mance runs.<br />

< 0, combination of options 2 and 4. Inner heliostats<br />

are aimed according to option 4. Heliostats<br />

at a radial zone position 1-IAUTOP are aimed<br />

according to option 2. This option is most<br />

useful <strong>for</strong> cavity receivers.<br />

Constraint: Maximum of 25 user defined aim points/<br />

zone. Code will only automatically generate<br />

up to 100 aim points.<br />

IREC = 2 or 4 if IAUTOP = 2 or 4<br />

IPROB # 4 (namelist BASIC) if IAUTOP = 5<br />

Default: IAUTOP = 0<br />

NUMPT(K,L) = NAX(K,L) = NAY(K,L) = 1<br />

XAIM(K,L,M) = YAIM(K,L,M) = 0.0<br />