IFOCUS<br />
XFoCALIKl<br />
YFOCAL K<br />
(K=l, NHAD)<br />
INDC<br />
ISB<br />
Default: XFOCUS = 1.0 (II.D-2,II.D-3)<br />
YFOCUS = 1.0<br />
Types of focusing:<br />
-- 0, individtral focus with focal length equal to the slant<br />
range;<br />
== 1, user defined focal length determined by XFOCAL<br />
and YFOCAL if zoning is used or focal length<br />
read off of individual heliostat data cards if<br />
this is an individual heliostat field (IUSERF = 3,<br />
Namelist FIELD); (can be used to <strong>prod</strong>uce a single<br />
focal length <strong>for</strong> the whole field).<br />
Constraint: XFOCUS = YFOCUS = 1.0<br />
Default: IFOCIJS = 1 (1I.D-2,11.D-3)<br />
User defined focal lengths <strong>for</strong> the Kth radial zone (note:<br />
the focal length = 1/2 radius of curvature ; XFOCAL(K) is<br />
the focal length in units of tower heights / THT in<br />
namelist REC) in the I,, direction and YFOCAL(K) is in the<br />
j,, direction.<br />
Default: XFOCAL = 13*6.00<br />
YFOCAL = 13r6.00 (11. D-2 ,II. D-3)<br />
Control parameter <strong>for</strong> more accurate heliostat images<br />
during per<strong>for</strong>mance only calculations:<br />
= 0, regular images;<br />
= 1; separate image generated from each cant<br />
panel instead of a single image from the whole<br />
heliostat. This significantly increases the<br />
running time. This option can only be used with a<br />
per<strong>for</strong>mance calculation and cannot be used in<br />
design optimization calculations.<br />
Constraint: INDC = 0 <strong>for</strong> a design calculation<br />
IAUTOP = 0 (Namelist REC) if INDC = 1<br />
ICANPL = 1 if INDC = 1<br />
Default: INDC = 0 (1II.F-1 ,VI.A-5)<br />
Parameter controlling overlapping of shadowing and<br />
blocking:<br />
= 0, no overlap. Most conservative assumption<br />
as shading and blocking losses are maximized.<br />
= 1, complete overlap. Lower bound on shading and<br />
blocking losses.<br />
Default: ISB = 0 (1II.E)