DHOPT<br />

IPRINT(1)<br />

(1=1, NYEAR)<br />

ITAPE<br />

During heliostat optimization the density and aspect<br />

ratio will be varied by no more than 1 f DHOPT from the<br />

initial values. The larger DHOPT the wider the search<br />

<strong>for</strong> the optimum and the poorer the numerical approximations<br />

used in finding the optimum.<br />

Constraint: 0 < DHOPT 5 0.20<br />

Default: DHOPT = 0.2 (IV . B-2,IV .C-7)<br />

Control parameter <strong>for</strong> zone by zone output of per<strong>for</strong>mance<br />

calculation. The annual zone by zone per<strong>for</strong>mance is<br />

always printed. The average per<strong>for</strong>mance of a user defined<br />

field at all times is always printed. In addition, <strong>for</strong> the<br />

Ith day of the NYEAR days (if IPROB=l or 2 the only day of<br />

the year is 1=1), IPRINT(1)<br />

= 0, no zone by zone output <strong>for</strong> this day;<br />

= 1, daily average printed;<br />

-= 2, each time step and daily average printed.<br />

If IPROR-3 then IPRINT( I)<br />

= 0, no zone by zone per<strong>for</strong>mance printed <strong>for</strong> the I<br />

zenith angle, UEL(1);<br />

= 2, zone by zone per<strong>for</strong>mance printed <strong>for</strong> every<br />

combination of the I solar zenith angle,<br />

UEL(I), and the NIJAZ values of the solar<br />

azimuthal angle (UAZ(1). . .UAZ(NUAZ)).<br />

Default: IPRINT = 9'0<br />

Control parameter <strong>for</strong> reading and writing files<br />

= 0, no reading or writing of files;<br />

= 1, output of per<strong>for</strong>mance run written on local file<br />

Unit 10 <strong>for</strong> use in subsequent design<br />

calculations; this option eliminates need to<br />

duplicate initial per<strong>for</strong>mance calculation <strong>for</strong><br />

different design runs when location and field<br />

options (latitude, dimensions, heliostat<br />

design, etc.) remain unchanged;<br />

= 2, initial per<strong>for</strong>mance input <strong>for</strong> design run read<br />

from local file Unit 20, which should be the file<br />

created on Unit 10 in a previous per<strong>for</strong>mance run<br />

with ITAPE=l; input Namelists FIELD, HSTAT, REC,<br />

NLFLUX, and NLEFF in per<strong>for</strong>mance roup are<br />

omitted with this option (see Table A-Z!.<br />

The user must be sure that the latitude,<br />

insolation model, sunshape, heliostat<br />

design, and receiver/field configuration<br />

read from Unit 20 are those desired in<br />

the present run.<br />

= 3, system input <strong>for</strong> per<strong>for</strong>mance calculation read<br />

from local file Unit 30, which should be the<br />

file created in a design/optimization<br />

175