CTK,REF (CSTREF) = $9.70 x loG<br />

VTK,REF (VSTREF) = 3740 m3<br />

XST (XST) = 0.6 (Reference 31)<br />

VTK,MAX (VMAX) = 1.23 x lo4 m3<br />

ESTOR,REF (ESTREF) =- 6.88 x lo8 watt-hrs<br />

V.A-9. Heat Exchanger Between the Receiver Fluid and the Storage Fluid-For<br />

current technology systems it may be desirable to have different types of fluids <strong>for</strong><br />

the receiver and <strong>for</strong> storage, since fluids which store energy well (e.g., molten ni-<br />

trate salt) may not absorb energy in a receiver as well as other fluids (e.g., liquid<br />

sodium). In this case, a separate heat exchanger is required as an interface be-<br />

tween the two fluids. The cost of that heat exchanger scales with thermal power<br />

at the base of the tower:<br />

~CHTXSTOR = CKN,REF<br />

Pth,KN,REF<br />

where CKN,REF = Cost of receiver fluid-to-storage fluid heat exchanger<br />

<strong>for</strong> the reference thermal power ($)<br />

Pth = Actual thermal power at the base of the tower<br />

= Reference thermal power at the base of the tower<br />

(V.A - 18)<br />

P~~,,KN,REF<br />

<strong>for</strong> the receiver fluid-to-storage fluid heat exchanger (watts)<br />

XKN,~ = Scaling exponent<br />

The cost of this heat exchanger is only included if the variable ICKN = 1<br />

(Namelist NLCOST). The default values are based on the cost of sodium steam<br />

generator heat exchangers:<br />

ICKN = 0<br />

CKN,REF (CKNREF) = $9.0 x loG<br />

XKN,~ (XKN) = 0.8<br />