S M ~ , = ~ solar F multiple <strong>for</strong> reference receiver pump design<br />

Pth,Rp,REF = thermal power to EPGS in reference receiver pump<br />

system (watts)<br />

XRP = scaling exponent <strong>for</strong> receiver pump<br />

CSP,REF = cost of reference storage pump ($)<br />

Pth,Sp,REF = thermal power to EPGS in reference storage pump<br />

system (watts)<br />

xsp = scaling exponent <strong>for</strong> storage pump.<br />

Default values are as follows:<br />

CRP,REF (CRPREF) = $2.1 x IO6<br />

THTRP,REF (TRPREF) = 170.0 m<br />

P~~,RP,HEF (PRPREF) = 2.6 x lo8 watts<br />

X R (XRP) ~ 0.85<br />

CSP,REF (CSPREF) = $4.70 x lo5<br />

Pth,Sp,~~~ (PSPREF) = 3.0 x lo8 watts<br />

xsp (XSP) = 0.15<br />

V.A-7. Piping-Piping costs are assumed to scale with tower height and with<br />

pipe diameter in relation to a reference system (Reference 39).<br />

CCPIPE = THT(~PHCHOT,REF<br />

+ ~PC~COLD,REF)<br />

(-1 XPIPE (V.A - 13)<br />

DREF<br />

where t p = ~ multiplier on THT to give total hot piping run as<br />

described in Section 1II.G-4<br />

CHOT,REF = reference hot pipe cost, including pipe, insulation,<br />

fittings, hangers, supports, installation ($/m)<br />

tpc = multiplier on THT to give total cold piping run (can be<br />

different from t p if ~ expansion allowance is less)<br />

CCOLD,REF = reference cold pipe cost, as above ($/m)<br />

D = pipe diameter (m)<br />

DREF = reference pipe diameter (m)<br />

xp~p~ = scaling exponent <strong>for</strong> piping.<br />