Mastercycler® pro Technical specifications Sample Handling 189 Description Mastercycler pro Mastercycler pro S Mastercycler pro 384 Thermoblock Aluminum Silver Aluminum Sample capacity 96 x 0.2 mL PCR tubes or 1 PCR plate 8 x 12 (unskirted, semi-skirted, skirted—according to SBS standard) Temperature control range of the block 4–99 °C 4–99 °C 4–99 °C 1 PCR plate 384 Temperature control mode Fast, Standard, Safe ; all available in gradient mode Heating technology of the block Peltier Elements, Triple Circuit Technology Gradient block Over 12 columns Over 12 columns Over 24 columns Gradient range 1–20 °C 1–24 °C 1–20 °C Gradient temperature range 30–99 °C 30–99 °C 30–99 °C Lid temperature range 37–110 °C 37–110 °C 37–110 °C Lid descent and closing pressure vapo.protect ® technology, with Thermal Sample Protection Block homogeneity 20–72 °C ±0.3 °C, 90 °C ±0.4 °C Control accuracy ±0.2 °C ±0.2 °C ±0.2 °C Heating rate* approx. 4 °C/s approx. 6 °C/s approx. 4 °C/s Cooling rate* approx. 3 °C/s approx. 4.5 °C/s approx. 3 °C/s Interfaces 1 x Centronics ® , 1 x RS-232, Control panel, one each of CAN_in/CAN_out Dimensions (W x D x H) 10.2 x 16.3 x 14.6 in/ 26 x 41.5 x 37 cm Product features ‡ Extremely fast heating and cooling rates— get results faster and do more in one day ‡ Ultimate reduction of evaporation for reliable results ‡ Gradient blocks with SteadySlope ® technology for protocol optimization ‡ Intuitive graphic user interface ‡ Display to indicate cycler number in a network ‡ Upgradable to real-time PCR ‡ 2-year warranty ‡ Optional self-test dongle available to test functionality of the Peltier Elements ‡ Stand alone system fits on virtually every lab bench and is operated by a control panel ‡ Expandable to a Mini Satellite System or network – Mini Satellite System: operated by Control Panel. Control up to 5 units with one Control Panel. Combine any block format. Expandable to a network. – Computer Network: combines up to 30 units for ultimate throughput. Operated by a computer and the CycleManager pro software. Benefit from a client/ server architecture and full software functionality. 10.2 x 16.3 x 14.6 in/ 26 x 41.5 x 37 cm 10.2 x 16.3 x 14.6 in/ 26 x 41.5 x 37 cm Weight 40.8 lbs /18.5 kg 40.8 lbs /18.5 kg 40.8 lbs /18.5 kg Power supply 120 V, 50–60 Hz 120 V, 50–60 Hz 120 V, 50–60 Hz Power consumption 950 W 950 W 950 W * Block temperature This product is licensed under U.S. patent Nos. 5,525,300, 5,779,981 and 6,054,263. The heated cover device is licensed under US 5,552,580 and foreign equivalents. The user of the Eppendorf Mastercycler pro might require additional rights for kits, reagents and other components required for his/her application. Such accompanying rights for these kits, reagents and other may be obtained by the respective holder of such rights. No rights are conveyed expressly, by implication or estoppel to any patents on real-time methods, including but not limited to 5‘ nuclease assays, or to any patent claiming a reagent or kit. Mastercycler pro upgraded to a Mastercycler ep realplex requires a Real-Time Thermal Cycler License under Applera’s United States Patent No. 6,814,934 and corresponding claims in non-U.S. counterparts. In the U.S.: Eppendorf North America 800-645-3050 · In Canada: Eppendorf Canada Ltd. 800-263-8715 E-mail: info@eppendorf.com · www.eppendorf.com 4 Thermocyclers
Thermocyclers 4 190 Sample Handling Mastercycler® pro Control panel programming features ‡ Highest degree of flexibility, graphical user interface ‡ Variable ramp rates ‡ Simulation mode for temperature control speed and protocols of the original Mastercycler family— heating 3 °C/s, cooling 2 °C/s ‡ Time and temperature increments ‡ Pause command ‡ Programmable alarm sound ‡ Freely configurable auto-restart dialogue Regulatory documentation Compliance with GMP/GLP guidelines is becoming increasingly important, particularly in the pharmaceutical and biotechnology industries. The Mastercycler pro system’s programming and user management system provides a GLP-conforming environment for your PCR assays. Technical specifications of the Control Panel Number of Mastercycler pro cyclers that can be controlled 1–5 Memory capacity 16 MB, >700 programs Memory expansion MultiMediaCard reader and 2 x USB port 2.0 Number of user-defined folders >100 Dimensions (W x D x H) 10.0 x 6.6 x 4.4 in/25 x 16.5 x 11 cm Interfaces 2 x USB port Weight 2.6 lb/1.2 kg Power supply, consumption Via the connected thermal module Order from your laboratory supply dealer. Product appearance, specifications, and/or prices are subject to change without notice. Program and user administration features ‡ One administrator to manage user and service functions ‡ Easy addition of new users with limited rights ‡ Ability for Mastercycler pro users to change their passwords; no administrator access to user passwords ‡ Password protection against unauthorized login ‡ A report file for each run, including total temperature profiling ‡ Development, testing and validation of the software using certified standards This product is licensed under U.S. patent Nos. 5,525,300, 5,779,981 and 6,054,263. The heated cover device is licensed under US 5,552,580 and foreign equivalents. The user of the Eppendorf Mastercycler pro might require additional rights for kits, reagents and other components required for his/her application. Such accompanying rights for these kits, reagents and other may be obtained by the respective holder of such rights. No rights are conveyed expressly, by implication or estoppel to any patents on real-time methods, including but not limited to 5‘ nuclease assays, or to any patent claiming a reagent or kit. Mastercycler pro upgraded to a Mastercycler ep realplex requires a Real-Time Thermal Cycler License under Applera’s United States Patent No. 6,814,934 and corresponding claims in non-U.S. counterparts.
- Page 1 and 2: 4 A History of Advanced PCR 184 Sam
- Page 3 and 4: 4 Summary of Applications 186 Sampl
- Page 5: Thermocyclers 4 188 Sample Handling
- Page 9 and 10: Thermocyclers 4 192 Sample Handling
- Page 11 and 12: Thermocyclers 4 194 Sample Handling
- Page 13 and 14: Thermocyclers 4 196 Sample Handling
- Page 15 and 16: Thermocyclers 4 198 Sample Handling
- Page 17 and 18: 4 PCR Plates 200 Sample Handling tw
- Page 19 and 20: 4 PCR Plates 202 Sample Handling tw
- Page 21 and 22: 4 PCR Tubes 204 Sample Handling PCR
- Page 23 and 24: 4 PCR Plates 206 Sample Handling tw
- Page 25 and 26: 4 Heat Sealing Materials 208 Sample
- Page 27 and 28: 4 Heat Sealing Materials 210 Sample
- Page 29 and 30: 4 Adapters 212 Sample Handling in s
- Page 31 and 32: Services - PCR 44 214 Sample Servic
- Page 33: Support and Services Directory Cont
Mastercycler® pro<br />
Technical specifications<br />
Sample Handling 189<br />
Description Mastercycler pro Mastercycler pro S Mastercycler pro 384<br />
Thermoblock Aluminum Silver Aluminum<br />
Sample capacity 96 x 0.2 mL PCR tubes or 1 PCR plate 8 x 12 (unskirted,<br />
semi-skirted, skirted—according to SBS standard)<br />
Temperature control range of the block 4–99 °C 4–99 °C 4–99 °C<br />
1 PCR plate 384<br />
Temperature control mode Fast, Standard, Safe ; all available in gradient mode<br />
Heating technology of the block Peltier Elements, Triple Circuit Technology<br />
Gradient block Over 12 columns Over 12 columns Over 24 columns<br />
Gradient range 1–20 °C 1–24 °C 1–20 °C<br />
Gradient temperature range 30–99 °C 30–99 °C 30–99 °C<br />
Lid temperature range 37–110 °C 37–110 °C 37–110 °C<br />
Lid descent and closing pressure vapo.protect ® technology, with Thermal Sample Protection<br />
Block homogeneity 20–72 °C ±0.3 °C,<br />
90 °C ±0.4 °C<br />
Control accuracy ±0.2 °C ±0.2 °C ±0.2 °C<br />
Heating rate* approx. 4 °C/s approx. 6 °C/s approx. 4 °C/s<br />
Cooling rate* approx. 3 °C/s approx. 4.5 °C/s approx. 3 °C/s<br />
Interfaces 1 x Centronics ® , 1 x RS-232, Control panel, one each of CAN_in/CAN_out<br />
Dimensions (W x D x H) 10.2 x 16.3 x 14.6 in/<br />
26 x 41.5 x 37 cm<br />
Product features<br />
‡ Extremely fast heating and cooling rates—<br />
get results faster and do more in one day<br />
‡ Ultimate reduction of evaporation for reliable results<br />
‡ Gradient blocks with SteadySlope ® technology for<br />
protocol optimization<br />
‡ Intuitive graphic user interface<br />
‡ Display to indicate cycler number in a network<br />
‡ Upgradable to real-time PCR<br />
‡ 2-year warranty<br />
‡ Optional self-test dongle available to test functionality<br />
of the Peltier Elements<br />
‡ Stand alone system fits on virtually every lab bench<br />
and is operated by a control panel<br />
‡ Expandable to a Mini Satellite System or network<br />
– Mini Satellite System: operated by Control Panel.<br />
Control up to 5 units with one Control Panel.<br />
Combine any block format. Expandable to a network.<br />
– Computer Network: combines up to 30 units for<br />
ultimate throughput. Operated by a computer and the<br />
CycleManager pro software. Benefit from a client/<br />
server architecture and full software functionality.<br />
10.2 x 16.3 x 14.6 in/<br />
26 x 41.5 x 37 cm<br />
10.2 x 16.3 x 14.6 in/<br />
26 x 41.5 x 37 cm<br />
Weight 40.8 lbs /18.5 kg 40.8 lbs /18.5 kg 40.8 lbs /18.5 kg<br />
Power supply 120 V, 50–60 Hz 120 V, 50–60 Hz 120 V, 50–60 Hz<br />
Power consumption 950 W 950 W 950 W<br />
* Block temperature<br />
This product is licensed under U.S. patent Nos. 5,525,300, 5,779,981 and 6,054,263. The heated cover device is licensed under US 5,552,580 and foreign equivalents. The user of the <strong>Eppendorf</strong> Mastercycler pro<br />
might require additional rights for kits, reagents and other components required for his/her application. Such accompanying rights for these kits, reagents and other may be obtained by the respective holder<br />
of such rights. No rights are conveyed expressly, by implication or estoppel to any patents on real-time methods, including but not limited to 5‘ nuclease assays, or to any patent claiming a reagent or kit.<br />
Mastercycler pro upgraded to a Mastercycler ep realplex requires a Real-Time Thermal Cycler License under Applera’s United States Patent No. 6,814,934 and corresponding claims in non-U.S. counterparts.<br />
In the U.S.: <strong>Eppendorf</strong> North America 800-645-3050 · In <strong>Canada</strong>: <strong>Eppendorf</strong> <strong>Canada</strong> Ltd. 800-263-8715<br />
E-mail: info@eppendorf.com · www.eppendorf.com<br />
4 Thermocyclers