Fire-Resistant Assemblies - USG Corporation
Fire-Resistant Assemblies - USG Corporation
Fire-Resistant Assemblies - USG Corporation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
A<br />
Partitions<br />
Steel Framed<br />
1 Hour <strong>Fire</strong>-Rated Construction Non-Loadbearing Acoustical Performance Reference<br />
Construction Detail Description Test Number STC Test Number Index<br />
wt. 6 • veneer plaster only (not drywall) 1/2" imperial GA-WP-1240 45 CK-664-1<br />
Based on 3-5/8" studs 24" o.c.<br />
with 1" mineral wool batt in cavity<br />
A-3<br />
3 5 ⁄8"<br />
brand <strong>Fire</strong>code C Core gypsum base and veneer<br />
finish or 5/8" Fiberock panels<br />
– 2-1/2" 25 gauge steel studs, 16" o.c.<br />
– joints staggered and taped<br />
– 1/16" veneer finish<br />
wt. 5 • 1/2" Sheetrock <strong>Fire</strong>code C Core gypsum panels UL Des U419 A-4<br />
3 1 ⁄2"<br />
– 2-1/2" 25 gauge studs 24" o.c. or U448<br />
– 1-1/2" thermaFiber SAFB<br />
– joints finished<br />
wt. 6 • 5/8" Sheetrock <strong>Fire</strong>code Core gypsum panels CEG 8-11-83 A-5<br />
3 3 ⁄4"<br />
– 2-1/2" 25 gauge steel studs 24" o.c.<br />
– 1-1/2" mineral wool batt<br />
– horiz joints directly opposite and finished<br />
– CEG 8-11-83 rating also applies to assembly<br />
with 1/2" Sheetrock <strong>Fire</strong>code C Core<br />
gypsum panels, panels and joints finished<br />
– CEG 5-9-84 rating also applies with imperial<br />
<strong>Fire</strong>code Core gypsum base and veneer finish<br />
surface<br />
• 5/8" Sheetrock <strong>Fire</strong>code Core gypsum UL Des U423 A-6<br />
panels<br />
– 3-5/8" 25 gauge steel studs 24”OC<br />
– joints finished<br />
– optional insulation<br />
– optional plywood or OSB for shear purposes<br />
wt. 7 • Face layer 1/2" Sheetrock <strong>Fire</strong>code C Core GA-WP-1090 A-7<br />
3 1 ⁄8"<br />
gypsum panels<br />
– 1-5/8" 25 gauge steel studs 24" o.c.<br />
• base layer 1/4" Sheetrock gypsum panels<br />
– joints finished<br />
10 <strong>USG</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong><br />
CEG 5-9-84<br />
47 SA-831001<br />
41 RAL-TL-69-148<br />
Based on same construction<br />
without thermaFiber SAFB<br />
45 RAL-TL-69-42<br />
48 SA-800422<br />
Based on 3-5/8" studs and 2" mineral<br />
wool batt<br />
53 CK-684-13<br />
Based on 1-1/2" mineral wool batt<br />
and 2-1/2" studs