FIGURE 7.51 Examples of special connections.<br />

STRUCTURAL STEEL CONSTRUCTION 7.109<br />

reactions, the moments balance out. But the case of live load on one beam only<br />

must be considered. And bear in mind the necessity of supporting the beam reaction<br />

as near as possible to the column center to relieve the column of bending stresses.<br />

When sp<strong>and</strong>rels <strong>and</strong> girts are offset from the column, a Z-type connection (Fig.<br />

7.51e) may be used. The eccentricity for beam-web fasteners should be taken as<br />

l 1, for column-flange fasteners as l 2, <strong>and</strong> for fasteners joining the two connection<br />

angles as l 3 when l 3 exceeds 2 1 ⁄2 in; smaller values of l 3 may be considered negligible.<br />

7.35.7 Simple, Rigid, <strong>and</strong> Semirigid Connections<br />

Moment connections are capable of transferring the forces in beam flanges to the<br />

column. This moment transfer, when specified, must be provided for in addition to