STRUCTURAL STEEL CONSTRUCTION 7.87<br />

TABLE 7.22 Allowable Horizontal-Shear Loads, q, for Connectors, kips<br />

(Applicable only to concrete made with ASTM C33 aggregates)<br />

Connector � 3.0<br />

ƒ� c<br />

ƒ� c<br />

� 3.5<br />

ƒ� c<br />

� 4.0<br />

1 ⁄2-in dia. � 2-in hooked or headed stud* 5.1 5.5 5.9<br />

5 1 ⁄8-in dia. � 2 ⁄2-in hooked or headed stud* 8.0 8.6 9.2<br />

3 ⁄4-in dia. � 3-in hooked or headed stud* 11.5 12.5 13.3<br />

7 1 ⁄8-in dia. � 3 ⁄2-in hooked or headed stud* 15.6 16.8 18.0<br />

3-in channel, 4.1 lb 4.3w† 4.7w† 5.0w†<br />

4-in channel, 5.4 lb 4.6w† 5.0w† 5.3w†<br />

5-in channel, 6.7 lb 4.9w† 5.5w† 5.6w†<br />

* Length given is minimum.<br />

† w � length of channel, in.<br />

TABLE 7.23 Shear-Load Factors for Connectors in Lightweight Concrete<br />

Air dry weight, pcf, of concrete 90 95 100 105 110 115 120<br />

Factors for ƒ�c � 4.0 ksi<br />

0.73 0.76 0.78 0.81 0.83 0.86 0.88<br />

Factors for ƒ�c � 5.0 ksi<br />

0.82 0.85 0.87 0.91 0.93 0.96 0.99<br />

If a concentrated load occurs between the points of maximum <strong>and</strong> zero moments,<br />

the minimum number of connectors required between the concentrated load <strong>and</strong><br />

the point of zero moment is given by<br />

� �<br />

V SM /M � S<br />

h t c s<br />

N2 � (7.70)<br />

q S � S<br />

t s<br />

where M � maximum moment, in-kips<br />

M c � moment, in-kips, at concentrated load � M<br />

S s � section modulus, in 3 , of steel beam relative to bottom flange<br />

S t � section modulus, in 3 , of transformed section of composite beam relative<br />

to bottom flange but not to exceed S t computed from Eq. (7.66).<br />

The allowable shear loads for connectors incorporate a safety factor of about<br />

2.5 applied to ultimate load for the commonly used concrete strengths. Not to be<br />

confused with shear values for fasteners given in Art. 7.30, the allowable shear<br />

loads for connectors are applicable only with Eqs. (7.67) to (7.69).<br />

The allowable horizontal shear loads given in Tables 7.22 <strong>and</strong> 7.23 may have<br />

to be adjusted for use with formed steel decking. For decking with ribs parallel to<br />

supports (Fig. 7.38a), the allowable loads should be reduced when w/h is less than<br />

1.5 by multiplying the tabulated values by<br />

��� �<br />

where w � average width of concrete rib, in<br />

h � nominal rib height, in<br />

w H<br />

0.6 � 1 � 1 (7.71)<br />

h h