Batch Microwave Scale-Up:<br />

2-Methylbenzimidazole (200 °C, 5 min, 5 M)<br />

Temperature [°C]<br />

MW instrument<br />

Monowave 300<br />

Synthos 3000 (HF 100)<br />

200<br />

150<br />

100<br />

50<br />

0<br />

Reaction volume<br />

(mL)<br />

20<br />

16 × 60 = 960<br />

Heating Profiles<br />

Yield in g<br />

(%)<br />

9.44 (95)<br />

465.7 (98)<br />

Monowave<br />

Synthos, HF 100<br />

0 5 10 15 20 25<br />

Time [min]<br />

30 35 40 45 50<br />

Ramp/hold/cooling<br />

time (min)<br />

1/5/6<br />

15/5/30<br />

Overall processing<br />

time (min)<br />

12<br />