27.02.2013 Views

Fischer Panda Energy Systems

Fischer Panda Energy Systems

Fischer Panda Energy Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2013 / 2014<br />

<strong>Fischer</strong> <strong>Panda</strong> <strong>Energy</strong> <strong>Systems</strong><br />

TM


2<br />

1. Power wherever you are<br />

<strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong><br />

based on <strong>Fischer</strong> <strong>Panda</strong> Generators and Alternators<br />

About this brochure : Everyone has different power requirements when travelling. This brochure presents an overview of<br />

<strong>Fischer</strong> <strong>Panda</strong> power systems available for a diverse range of mobile power applications. An extensive range is available<br />

to cover your individual energy requirements.<br />

1. Power wherever you are<br />

2. SyStem ConCePtS<br />

3. Power ComPonentS<br />

4. SyStem ComPonentS<br />

5. DiStributorS anD ServiCeS<br />

<strong>Fischer</strong> <strong>Panda</strong>, areas of application and installation<br />

examples<br />

Efficient and powerful energy systems using <strong>Fischer</strong> <strong>Panda</strong><br />

Generators as the primary power source. These systems are<br />

suited for typical commercial and recreational applications.<br />

They are flexible and can be tailored to suit individual<br />

requirements and budgets.<br />

Major components for generating electrical power: <strong>Fischer</strong><br />

<strong>Panda</strong> Alternators, <strong>Fischer</strong> <strong>Panda</strong> DC Generators and<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generators<br />

Primary components used to connect, control and supply the<br />

electrical consumers within the power system. Some of these<br />

components may already be present in your system.<br />

<strong>Fischer</strong> <strong>Panda</strong> provides experienced support worldwide<br />

for all types of power systems. You will profit from our<br />

distributors‘ knowledge when planning your energy system.


1.1 Power - Wherever you are 4<br />

1.2 Power for a Mobile World 5<br />

1.3 Power for Marine and Mobile Vehicles 6<br />

2.1 <strong>Systems</strong> - to suit your energy needs 8<br />

2.2 <strong>Fischer</strong> <strong>Panda</strong> Basic DC Alternator <strong>Systems</strong> 10<br />

2.3 <strong>Fischer</strong> <strong>Panda</strong> Extended DC Generator <strong>Systems</strong> 12<br />

2.4 <strong>Fischer</strong> <strong>Panda</strong> AC Generator <strong>Systems</strong> 14<br />

2.5 <strong>Fischer</strong> <strong>Panda</strong> Parallel AC Generator <strong>Systems</strong> 16<br />

3.1 High Performance Alternators 18<br />

3.2 <strong>Panda</strong> Marine DC Generators 19<br />

3.3 <strong>Panda</strong> Marine AC Generators 20<br />

3.4 <strong>Panda</strong> Vehicle Generators - Designed for all types of vehicles 26<br />

4.1 MultiPlus Inverter / Charger 28<br />

4.2 Quattro with AC Transfer Switch for 2 AC Inputs 34<br />

4.3 Automatic AC Transfer 36<br />

4.4 System Control Board 37<br />

4.5 AC Distribution Box 38<br />

4.6 Parallel Power Transfer Unit 39<br />

4.7 Generator Module - VE.NET Connectivity 40<br />

4.8 Battery Module - VE.NET Connectivity 41<br />

5.1 Dealers & Services Germany 44<br />

5.2 Distributors & Services Worldwide 48<br />

5.3 Caribbean Quick Reference 54<br />

1. Power wherever you are<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Power ConCePtS Power wherever you are<br />

Power ComPonentS<br />

SyStem ComPonentS<br />

DiStributorS anD ServiCeS<br />

3


4<br />

1. Power wherever you are<br />

Power - wherever you are<br />

Founded in 1977, the company began with the production of<br />

marine refrigeration and cooling systems. To effectively power<br />

this type of system, the world‘s first water-cooled generator<br />

known as the “<strong>Panda</strong>” was built. Since then, the product<br />

generator has evolved into a wide range of products.<br />

The company, based in Paderborn-Germany, was<br />

originally founded under the name Icemaster GmbH<br />

and renamed to <strong>Fischer</strong> <strong>Panda</strong> GmbH in 2007. Today,<br />

<strong>Fischer</strong> <strong>Panda</strong> has established itself as a worldwide<br />

leader providing solutions for mobile power supply.<br />

<strong>Fischer</strong> <strong>Panda</strong> Generators feature an effective watercooling<br />

system and a lightweight, compact construction.<br />

The water-cooled diesel generators from <strong>Fischer</strong> <strong>Panda</strong><br />

are renowned worldwide for being innovative, reliable and<br />

extremely quiet. The product range includes over two hundred<br />

different generators - spanning a performance range from 2.5 kW to 120<br />

kW. They are sold in over sixty countries worldwide under the trade name “<strong>Fischer</strong> <strong>Panda</strong>.” These highly-proven<br />

marine and vehicle generators supply power to on-board electrical systems, electric drives and complete mobile<br />

energy systems.<br />

The company philosophy “Generators for Mobile Power Supply” has since developed into a strategy which<br />

now appears in the company slogan “Power – wherever you are“. <strong>Fischer</strong> <strong>Panda</strong> is no longer solely a<br />

generator manufacturer. The company is a system supplier who accompanies the customer through all phases<br />

from initial design to the installation of the complete mobile system.<br />

Enjoy all the comforts of home<br />

wherever you are


<strong>Fischer</strong> <strong>Panda</strong> - Power for a mobile world<br />

Recreational<br />

Yachts<br />

Catamarans<br />

Cruisers<br />

Powerboats<br />

Luxury Mobile Homes<br />

Expedition Vehicles<br />

Commercial<br />

Environmental Monitoring Vehicles<br />

Mobile Broadcasting Vehicles<br />

Commercial Marine<br />

Promotion and Mobile Stages<br />

Formula 1 Teams<br />

Railway Vehicles<br />

Emergency Services and Military<br />

Police and Rescue Vessels<br />

Coast Guard and Customs Boats<br />

Blood Donor Vehicles<br />

Mobile Command Units<br />

Fire Fighting Vehicles<br />

Ambulances<br />

1. Power wherever you are<br />

5


6<br />

1. Power wherever you are<br />

Power for Marine and Mobile Vehicles<br />

However you travel, with <strong>Fischer</strong> <strong>Panda</strong> you will always have enough power<br />

The innovative energy systems from <strong>Fischer</strong> <strong>Panda</strong> provide power for<br />

marine and land-based vehicles.<br />

All forms of electrical energy can be made available: single or threephase,<br />

AC or DC, power for domestic or drive purposes. <strong>Fischer</strong><br />

<strong>Panda</strong> can be found providing power to these in a wide range of<br />

commercial and recreational applications worldwide.<br />

A high standard of quality has always stood in the forefront<br />

of the company‘s 30-year history. With a dealer and service<br />

network throughout more than 60 countries worldwide, we<br />

provide all our systems from 2.5 kW to 120 kW with an<br />

extensive service guarantee.<br />

Power for Navigating Oceans<br />

Low weight, compact construction, low noise and high efficiency are key features of the <strong>Fischer</strong> <strong>Panda</strong> Hybrid System.<br />

For these reasons, adventure specialist Steve Fosset and his team had a compact <strong>Panda</strong> AGT 4000 DC-PMS Generator<br />

on-board during their record breaking Atlantic crossing.<br />

4 kW<br />

Power for Recreational Cruising and Sailing<br />

All the comforts of home - wherever you are. As part of the on-board power system, <strong>Fischer</strong> <strong>Panda</strong> supplies power to<br />

cabin, kitchen and living areas on motor and sailing yachts used for recreational cruising and sailing worldwide.<br />

4 kW<br />

Photo: Peter Szamer<br />

Photo: Peter Szamer


Mobile Telecommunications and Broadcasting<br />

2 x 25 kW<br />

Power for Mobile Stages, Touring and Promotions<br />

This interesting truck from the tyre producer “Fulda” functions as a mobile stage for large events. The<br />

trailer can be opened to 110°, so that an enormous stage is produced. Two 40 kW <strong>Fischer</strong> <strong>Panda</strong><br />

Generators supply the stage lighting, sound equipment and projection screen with power.<br />

85 kW<br />

1. Power wherever you are<br />

Power for mobile command centres equipped with telecommunication and satellite systems. 2 x 25 kW <strong>Fischer</strong><br />

<strong>Panda</strong> Generators produce electricity for the 3-phase power supply. Alternators, gel battery bank and combined<br />

inverter/chargers form an uninterruptible power supply (UPS) ensuring energy is always available.<br />

Formula-One Racing Teams<br />

2 x 40 kW<br />

This impressive trailer belongs to the “Midland F1” racing team. At the touch of a button the upper half of the trailer<br />

rises upwards to form an additional floor and doubles the space available. A 85 kW <strong>Panda</strong> vehicle generator provides<br />

three-phase power to all the systems and equipment.<br />

7


8<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

Power <strong>Systems</strong> - to suit your energy needs<br />

Hairdryers, electric ovens, washing machines, hot plates, boilers, air<br />

conditioners, diving compressors and power tools need a great amount<br />

of energy to operate and some require even more just to start!<br />

Even if your battery bank allows you to connect a number of<br />

smaller devices and use them for a limited period of<br />

time, your domestic batteries will soon reach their<br />

limits. It is not usually practical or even desirable<br />

to increase the capacity of the battery bank so that<br />

it can serve as the only source of electrical energy<br />

for your appliances. <strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong><br />

provide you with intelligent, innovative solutions<br />

to ensure that you have sufficient energy even<br />

when there is no shore power connection available.<br />

These systems can be integrated to enhance existing<br />

installations or create a completely new power system<br />

wherever you are and however you are travelling.<br />

System Concept 1: Basic DC Alternator <strong>Systems</strong><br />

<strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong> with high performance alternators<br />

- up to 4 kW performance from the main engine<br />

when cruising.<br />

Page 10-11<br />

System Concept 2: Extended DC Generator <strong>Systems</strong><br />

<strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong> with permanent magnet DC<br />

generators - for up to 8 kW continuous performance and<br />

peak loads up to 15 kW.<br />

Page 12-13<br />

up to 4 kW<br />

Ideal for vessels up to 35 feet or<br />

smaller motorhomes & RVs<br />

up to 8 kW<br />

Ideal for vessels up to 42 feet<br />

or motorhomes & specialist vehicles


System Concept 3: AC Generator <strong>Systems</strong><br />

<strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong> with AC generators from 4 kW - for<br />

systems requiring a continuous performance from 8 to 120 kW and<br />

running multiple consumers simultaneously.<br />

Page 14-15<br />

System Concept 4: Parallel AC Generator <strong>Systems</strong><br />

<strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong> with AC generators in parallel - for<br />

covering high peak periods and supplying power for longer periods<br />

without being shutdown for maintenance.<br />

Page 16-17<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

up to 110 kW<br />

Ideal for vessels from 38 feet<br />

or special & promotion vehicles<br />

up to 200 kW<br />

9


10<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

System 1: Basic DC Alternator <strong>Systems</strong> - up to 4 kW<br />

Suitable for powering air conditioning up<br />

to 16.000 BTU, lighting, communications,<br />

navigation, smaller fridges and freezers<br />

<strong>Fischer</strong> <strong>Panda</strong> has solutions to offer even when there is not<br />

enough room for a conventional AC generator. Depending on<br />

the type of vessel, either a HTG high-performance alternator<br />

(fitted to the main engine) or by installation of a compact<br />

DC generator (which is typically half the size of a standard<br />

generator) to ensure that power on-board is available.<br />

The powerful HTG alternator quickly and reliably charges the<br />

battery bank while cruising. When used in conjunction with<br />

a <strong>Panda</strong> MultiPlus, 230 Volts AC is available throughout the<br />

day even when not continually cruising. The MultiPlus System<br />

is available for all mobile vehicle and marine applications even<br />

coaches and locomotives. This enables most commercial airconditioning<br />

units (Climma, Coleman or Electrolux) to be operated.<br />

More independence when travelling<br />

There is always sufficient energy available for your<br />

appliances.<br />

Efficient battery charging is carried out even when covering<br />

shorter distances.<br />

MultiPlus can provide limited AC power indirectly from the<br />

battery bank (silent power at night) or when moored or<br />

anchored wherever shore power is not available.<br />

Benefits when connected to shore power<br />

Even with a weak shore power connection, the MultiPlus<br />

can help to cover short peak AC loads by combining shore<br />

power with energy from the batteries.<br />

Regulation of the amount of power drawn from the shore<br />

power connection ensures safe charging and prevents land<br />

fuses from being tripped.<br />

Surplus energy from the shore power connection can be<br />

used to recharge the batteries.<br />

Ideal for vessels up to 35 feet or<br />

smaller motorhomes & RVs<br />

*1) MultiPlus and other primary components are available in custom-casings specifically for OEM contracts


Boiler<br />

Water Heating<br />

Shore power<br />

HTL Charging Converter<br />

<strong>Fischer</strong> <strong>Panda</strong> HTG<br />

Alternator<br />

Electric Stove<br />

Hairdryer<br />

Fridge<br />

Power System Controls<br />

Battery Bank<br />

Water Pumps<br />

Television & Radio<br />

MultiPlus *1)<br />

Charger & Inverter<br />

“ Up to 4 KW continuous performance when cruising”<br />

Consumer Electronics<br />

Cabin Lighting<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

AC Power<br />

DC Distribution Box<br />

DC Power<br />

Page 18<br />

Page 28<br />

Page 38<br />

Page 42<br />

11


12<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

System 2: Extended DC Generator <strong>Systems</strong> - up to 15 KW<br />

Suitable for powering air-conditioning units<br />

up to 32.000 BTU, fridges, freezers and<br />

diving compressors such as the Bauer Junior<br />

Just 2 or 3 periods of 30 minutes a day are sufficient for<br />

supplying a yacht (approx.12 meters) with enough energy<br />

for the whole 24 hour period. A continual supply of AC<br />

power is supplied throughout the day from the battery<br />

bank via an inverter.<br />

This power supply system is best suited for requirements<br />

above 6 kW. Standard AC electrical consumers such as<br />

washing machines, ovens, and kitchen appliances can be<br />

used. This system can also be used to power smaller (up<br />

to approx. 32.000 BTU) air conditioning systems.<br />

More independence when travelling<br />

There is always sufficient power so you do not need to return<br />

to shore or start the ship‘s main engine. This allows you to<br />

enjoy longer trips.<br />

AC power is supplied indirectly from the battery bank and the<br />

generator is not required to run continuously every time power<br />

is needed. This is the “silent AC power”- concept.<br />

The generator starts and stops automatically so the batteries<br />

are always charged and sufficient energy is available throughout<br />

the day.<br />

Benefits when connected to shore power<br />

Even with a weak shore power connection, the MultiPlus can<br />

help to cover short peak AC loads by combining shore power<br />

with energy from the batteries.<br />

Regulation of the amount of power drawn from the shore<br />

power connection ensures safe charging and prevents land<br />

fuses from being tripped.<br />

Surplus energy from the shore power connection can be used<br />

to recharge the batteries.<br />

*1) MultiPlus and other primary components are available in custom-casings specifically for OEM contracts<br />

Ideal for vessels up to 42 feet<br />

or motorhomes & specialist vehicles<br />

Air Conditioning<br />

up to 32.000 BTU<br />

Vacuum Cleaner<br />

Water Heating<br />

Cabin Lighting<br />

Hairdryer


Fridge<br />

Shore power<br />

<strong>Fischer</strong> <strong>Panda</strong> DC Generator<br />

Electric Stove<br />

Cabin Instruments<br />

Boiler<br />

Power System Controls<br />

Battery Bank<br />

Television & Radio<br />

Water Pumps<br />

MultiPlus *1)<br />

Charger & Inverter<br />

Portable Computers<br />

AC Distribution Box<br />

DC Distribution Box<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

“Up to 8 KW continuous performance and 15 KW for peak periods”<br />

Page 19<br />

Page 28<br />

Page 38<br />

Page 46<br />

13


14<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

System 3: AC Generator <strong>Systems</strong> - 4 to 110 KW<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generator <strong>Systems</strong> are perfect for<br />

applications requiring 4 to 110 kW, especially when very<br />

demanding or multiple AC consumers are required for<br />

prolonged periods of time.<br />

The highly efficient <strong>Fischer</strong> <strong>Panda</strong> AC Generator is not only<br />

capable of supplying the necessary current for starting air<br />

conditioning units and electric motors, the generator can<br />

also supply AC with a tolerance of ±3V. When fitted with the<br />

patented Voltage Control System (VCS), the <strong>Fischer</strong> <strong>Panda</strong><br />

Generator is ideal for sensitive electrical systems.<br />

An AC <strong>Fischer</strong> <strong>Panda</strong> Power System ensures that a fully selfsufficient<br />

power supply is available - wherever you are.<br />

More independence when travelling<br />

Easy to start and run demanding equipment such as air<br />

conditioners and diving compressors which require high<br />

inductive loads at the touch of a button.<br />

Use of domestic appliances such as heaters, ovens, hair<br />

dryers, vacuum cleaners, coffee machines and boilers for<br />

longer periods or even simultaneously.<br />

Full independence from shore power.<br />

Benefits when connected to shore power<br />

Even with a weak shore power connection, the MultiPlus<br />

can help to cover short peak AC loads by combining shore<br />

power with energy from the batteries.<br />

Regulation of the amount of power drawn from the shore<br />

power connection ensures safe charging and prevents<br />

land fuses from being tripped.<br />

Surplus energy from the shore power connection can be<br />

used to recharge the batteries.<br />

“Continuous power for ALL electrical<br />

consumers from 4 KW to 110 KW”<br />

Ideal for vessels from 38 feet<br />

or special & promotion vehicles<br />

Diving Compressor<br />

*1) MultiPlus and other primary components are available in custom-casings specifically for OEM contracts<br />

Full Air Conditioning<br />

Saloon Entertainment<br />

Water Heating


Fridge<br />

Water Pumps<br />

<strong>Fischer</strong> <strong>Panda</strong> AC<br />

Generator<br />

Shore power<br />

Battery Bank<br />

Vacuum Cleaner<br />

Consumer Electronics<br />

Power System Controls<br />

AC Supply Switching<br />

(Automatic available)<br />

Toaster<br />

Water Boiler<br />

Television & Radio<br />

MultiPlus *)<br />

Charger & Inverters<br />

Electric Oven<br />

AC Distribution<br />

DC Distribution<br />

Cabin Instruments<br />

Autopilot<br />

Cabin Lighting<br />

UHF/VHF Radio<br />

Hairdryer<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

Anchor Winch<br />

Seite 20<br />

Seite 28<br />

Seite 38 / 42<br />

Seite 42<br />

15


16<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

System 4: Parallel AC Generators <strong>Systems</strong><br />

Operational reliability for all performance ranges up to 200 KW<br />

Installing two generators in parallel to operate together<br />

has two main advantages. Either they can be run together<br />

which will provide the system with twice as much power with<br />

enough supply for very demanding peak periods or the load<br />

can be switched from one generator to the other without<br />

having to switch off the entire system.<br />

Two generators allow unexpectedly large loads or longer<br />

peak periods of demand to be covered. When the demand<br />

drops back to the normal level, only one smaller generator<br />

is required to then run which is more efficient than running a<br />

larger generator with a low load.<br />

When power is required for very long periods of time, the<br />

second generator can be started and brought “online” to take<br />

from the first. The first generator can then be safely switched off<br />

for maintenance purposes without having to shutdown the entire<br />

power system. If the primary power generator fails, a second<br />

generator is always available to supply the power without having<br />

to rely on a backup system with reduced capacity. This is suited for<br />

applications which may require a full energy supply in reserve. This<br />

system does not feature load-sharing capabilities for safety reasons.<br />

Both generators are coupled and operate together as one unit.<br />

To increase operational safety both generators are shutdown if a<br />

system failure occurs.<br />

Cabin Lighting<br />

Full Air Conditioning<br />

Television & Video<br />

Water Boiler<br />

Hot Water<br />

Fridge / Freezers<br />

Electric Oven<br />

Consumer Electronics<br />

Toaster


<strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

Remote Control Panel<br />

Remote Control Panel<br />

Parallel System Benefits<br />

<strong>Fischer</strong> <strong>Panda</strong> Parallel Unit<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

Switch loads from one generator to the other without shutting down the complete system<br />

Peace of mind - always one generator ready to supply the system in reserve<br />

One smaller generator can efficiently cover lower power demands<br />

Peak Performance - cover demanding peak periods by running generators together<br />

Cover unexpectedly larger power demands<br />

Flexible - when not enough room for a single large generator is available<br />

Diving Compressor<br />

Saloon Entertainment<br />

Autopilot<br />

Vacuum Cleaner<br />

Hairdryer<br />

Running Water<br />

Cabin Lighting<br />

Anchor Winch<br />

2. <strong>Fischer</strong> <strong>Panda</strong> Power systems<br />

AC Distribution Box<br />

AC Power<br />

“Load switching and operational reliabilty<br />

for very demanding power systems”<br />

Page 20<br />

Page 38<br />

Page 39<br />

17


18<br />

3. Power ComPonents<br />

High Performance Alternators<br />

The 3-phase <strong>Panda</strong> HTG 4000 alternator is designed to operate in<br />

conjunction with a HTL charging converter and supply power with a<br />

performance which until recently would not have been thought possible.<br />

Compactly designed - it is suitable for installing in even the most confined<br />

spaces.<br />

The HTG is highly efficient (exceeding 80%) and supplies a primary 3-phase voltage<br />

of 230-400 V to the HTL charging converter. The HTG is connected by means of a thin<br />

cable (4 x 25 mm²) to the HTL which then regulates the battery charge.<br />

Efficient recharging, ensures the batteries are protected from the damage caused by deep<br />

discharging. Regular recharging with shorter intervals can also help prolong the batteries life span.<br />

The HTL must be placed as close as possible to the batteries to ensure an optimal charging voltage<br />

When the HTG 4000 alternator is used in conjunction with an inverter (i.e. Victron Phoenix<br />

12/3000) it can produce up to 3kW continuously and form a complete power system. If<br />

only low performance is required the inverter supplies energy directly from the battery. This<br />

power system is suitable as a backup system for all mobile requirements, such as yachts,<br />

motor-homes, trucks etc especially if there is no room for a standard <strong>Panda</strong> generator.<br />

Vehicle air-conditioning units (such as Coleman Mach III or Electrolux) can be run<br />

stationary or while travelling. If the nominal performance is required for periods when the<br />

vehicle is stationary such as when the engine idles, the ability to match the required speed<br />

can be achieved by increasing the idling speed.<br />

High Performance Alternator HTG 4000<br />

Nominal output 3.2 kW<br />

Primary voltage 240 -400 volts / 3 phase (300-1000 Hz)<br />

Max. Current each phase 7.7 A<br />

Max. Output 3.2 W at 6000 rpm (40 ° C)<br />

Max. Constant charging rate 220/110 A DC at 12/24 V<br />

Max. Speed 14000 /16000 rpm<br />

Rotational left and right<br />

Cooling Air-cooled<br />

HTG Alternator HTL- Charging Converter Inverter 230 V Circuit Electrical Consumers<br />

Battery Bank<br />

Battery Charger / Regulator HTL 4.000 - 12 HTL 4.000 - 24<br />

Primary voltage (input) 240 V AC<br />

Max. Current (input) 7,7A<br />

Max. Charging rate DC 220 A (14.1 V regulated) 110 A (28.2 V regulated)<br />

Dimensions L x W x H (mm) 340 x 280 x 190<br />

Weight (kg) 22.2


<strong>Panda</strong> Battery Charging Generators<br />

<strong>Fischer</strong> <strong>Panda</strong> Hybrid DC Generators are fully enclosed within<br />

a sound insulated capsule and featuring a lightweight compact<br />

construction. They provide effective and fast battery charging.<br />

They function ideally within a battery-based power system when<br />

AC demands are required on board your vessel and these can be<br />

supplied via an inverter (see Multi Plus) from the battery bank.<br />

The DC generators are available in a wide range of standard<br />

voltages 12V / 24V / 48V to suit typical mobile power systems.<br />

Other voltages are available on request.<br />

Vehicle versions for modular installation allow the radiator to be<br />

installed externally on the roof to ensure the best possible cooling.<br />

The AGT generators feature the patented voltage control system<br />

(VCS) as standard to ensure that the voltage with a ±3 V tolerance<br />

is available when running.<br />

The DC-AC Power System (DAPS)<br />

For a flexible supply of energy for your domestic consumers throughout<br />

the day, the <strong>Panda</strong> AGT Generator operates as part of an intelligent<br />

Hybrid <strong>Energy</strong> Power System.<br />

As only a small amount of energy is usually required, the generator<br />

does not have to continually run. A battery bank of sufficient<br />

capacity supplies energy throughout the day. The generator only runs<br />

(automatically) when the batteries require recharging.<br />

The Hybrid <strong>Energy</strong> System is designed so that the generator only has<br />

to run 2-3 times a day to supply sufficient power for a 24 hour period.<br />

Running time efficiency is increased. Low noise, energy saving and<br />

ecological aspects are good reasons for making use of the Hybrid<br />

<strong>Energy</strong> Power System.<br />

3. Power ComPonents<br />

<strong>Fischer</strong> <strong>Panda</strong><br />

Hybrid 4000-12 DC PMS<br />

Inverter<br />

Electrical Consumers<br />

19


20<br />

3. Power ComPonents<br />

<strong>Panda</strong> Marine AC Generators<br />

Water-cooled windings<br />

Water-cooling for engine and generator<br />

No cooling air flow inside capsule<br />

Modular design ensures installation flexibility<br />

No appreciable warming of the installation area<br />

Water-cooled silencer (up to 25 kW)<br />

<strong>Fischer</strong> <strong>Panda</strong> PSA Generators feature all the reliability and safety of the asynchronous generator, provide fully watercooled<br />

systems for both winding and engine, are fully enclosed within a sound insulated capsule and have a lightweight<br />

compact construction. They are the right choice for operating demanding consumers such as air conditioning and diving<br />

compressors. They also produce an extremely clean sine wave for sensitive electronic equipment. No cooling air is required<br />

inside of the capsule. This helps to ensure that ambient temperatures remain constant. The stator is electrically indestructible<br />

and features a lifetime guarantee.<br />

A wide range of voltage and frequencies are available - 50 Hz / 230 V / 400 V @ 3000 / 1500 rpm and 60 Hz / 120 V /<br />

240 V / 208 V @ 1800 / 3600 rpm. Vehicle versions for modular installation allow the radiator to be installed externally on<br />

the roof thus ensuring the best possible cooling. Many versions also feature a patented voltage control system (VCS) which<br />

ensures that a voltage with ±3 V is available.<br />

Basic Line: <strong>Panda</strong> Marine Generators without electronic regulation<br />

These <strong>Panda</strong> generators are ideal for those interested in gaining a fair price. The<br />

generators are identical to the corresponding Premium Line models in respect of all main<br />

components, such as motor, generator, sound insulation casing, water-cooling. In the case<br />

of Basic Line generators, the electronic speed control is not fitted. The voltage tolerance lies<br />

therefore within an acceptable range of ±8 %. This is similar to a shore power connection.<br />

Premium Line: <strong>Panda</strong> Marine Generators with VCS Voltage Control<br />

The <strong>Panda</strong> Premium Line generators (NE) have been fitted for many years with<br />

the tried and tested VCS (Voltage Control System) whereby the motor speed is<br />

progressively controlled. This has an enormously positive effect on the exhaust<br />

emission and ensures that the generator achieves up to 15 % more effective<br />

performance than other non-controlled generators. The VCS adjusts the<br />

voltage with a tolerance of +/- 3 volts in the range up to 80 % of the nominal<br />

performance. An external AC control box contains the VCS and the capacitors<br />

which are used for boosting the starting current.<br />

iSeries: <strong>Panda</strong> Marine Generators with variable speed technology<br />

The new <strong>Panda</strong> iSeries generators are the first of the next generation of compact,<br />

super silent and powerful generators from <strong>Fischer</strong> <strong>Panda</strong>. Using modern diesel<br />

engines which meet the latest emission standards and variable speed technology,<br />

the operating speed can be adjusted to match the load to ensure an efficiency<br />

while supplying extremely stable voltage and frequency.<br />

The generators are fitted with the highly regarded sound insulation and watercooling.<br />

The <strong>Panda</strong> iSeries generator have been especially designed to be<br />

light and compact.<br />

Test the difference and enjoy your time on-board your boat with more power<br />

and comfort. The generator is not only for yachts, a vehicle version is also<br />

available for your “home on the road“ within your motor home.


The<br />

season<br />

was<br />

super...<br />

“Hello again and thank you so much!<br />

Photos: ClownfishCharter<br />

www.clownfish-diving.de<br />

The season was super, we gained a lot of experience and are<br />

all set for 2008! Bookings have already been made and we<br />

are working through a pile of inquiries. Here are some photos<br />

of the <strong>Panda</strong> -Bauer combination on board our catamaran!<br />

The Mariner 250 could also be fitted in the back box and we<br />

did not have to modify anything! After the diving platform had<br />

been installed, we only needed to lay the air-filling hoses to the<br />

stern side and our ‘Diving-Sailing Catamaran’ was finished.<br />

- Best regards Andreas Ketzel”<br />

3. Power ComPonents<br />

21


22<br />

3. Power ComPonents<br />

100% Water-cooled and super-silent<br />

Performance stability through dual-circuit cooling<br />

Water-cooled windings<br />

Dual-circuit cooling<br />

Water-cooling for engine and generator<br />

No appreciable warming of engine room<br />

Since 1988, <strong>Fischer</strong> <strong>Panda</strong> has manufactured more than 20,000 marine<br />

generators with this technology. One of the reasons for the superior efficiency<br />

of <strong>Panda</strong> Generators is the very effective cooling system, it ensures that the<br />

temperatures inside the sound insulation capsule remains within an acceptable<br />

range even in tropical conditions at the same time achieving the best possible<br />

sound insulation as free-flowing cooling air is not required.<br />

Dual-circuit cooling for generator and engine<br />

Seawater with high-salt content and tropical temperatures increases the danger that metal can be affected by galvanic<br />

corrosion (Electrolysis). Even a very small current can have a destructive effect. Therefore, <strong>Fischer</strong> <strong>Panda</strong> uses for all <strong>Panda</strong><br />

Generators from 3.2 kW upwards, a dual-circuit cooling system. The engine and generator are cooled by freshwater.<br />

Seawater only comes into contact with the heat exchanger, which is manufactured from a top quality alloy (CuNi10Fe).<br />

Less space required for installation<br />

Water-cooled winding<br />

Can be installed anywhere onboard<br />

Hermetically sealed capsule<br />

All connections prefitted on capsule<br />

Super-Silent Sound Insulation System<br />

<strong>Panda</strong> Marine Generators up to 25 kW, are delivered<br />

with a GFK sound insulation capsule with “3D” sound<br />

insulation material as standard (optional: sound<br />

insulation material: “4DS”).<br />

From 30 kW, the capsule is delivered as a stainless<br />

steel-version MPL. The MPL sound insulation casing<br />

can be split up and consists of 6 - 11 parts, depending<br />

on the size of the generator. The MPL capsules are also<br />

available at an extra cost for generators from 6 kW to<br />

25 kW.<br />

The sound insulation material is available in three<br />

different versions:<br />

“3D” - 3 layers, up to 25 mm thick<br />

“4DS” - up to 5 layers, up to 40 mm thick<br />

“6DS” - up to 6 layers, up to 60 mm thick<br />

Water-cooled Exhaust Silencer<br />

PVMV-N, PVK-U and PVK-UK generators (up to<br />

25 kW) are fitted with an internal water-cooled<br />

exhaust silencer.<br />

Modular design ensures installation flexibility<br />

No appreciable warming of the installation area<br />

Super-silent sound insulation system<br />

Water-cooled silencer (up to 25 kW)<br />

No cooling air circulating within capsule<br />

GFK Sound insulation<br />

capsule is standard for<br />

generators up to 25 kW.<br />

Stainless-steel sound-insulation<br />

capsule “MPL” for generators<br />

from 30 kW.


The best choice for cooling<br />

Vehicle Installation - roof-mounted radiator<br />

The radiator must be installed where good access for<br />

fresh air circulation is guaranteed.<br />

The best location is<br />

horizontally on the<br />

roof of the vehicle.<br />

The radiator has<br />

an integrated<br />

expansion tank.<br />

Vehicle Installation - side-mounted radiator<br />

A radiator can be fitted to the vehicle‘s side<br />

if there is no room on the roof.<br />

Vehicle Installation - underneath chassis<br />

It may be possible to mount a radiator under<br />

the chassis if it is not possible to mount the<br />

radiator on the roof or the vehicle‘s side.<br />

Sufficient clearance must be available to allow<br />

the air to circulate correctly.<br />

Marine Installation - keel cooling<br />

An interesting alternative to seawater cooling<br />

for commercial marine vessels eliminating<br />

the need for raw water pumps, strainers and<br />

an inboard heat exchanger.<br />

Radiator mounted<br />

underneath<br />

vehicle<br />

Keel cooler<br />

Side-mounted<br />

radiator<br />

Expansion tank<br />

3. Power ComPonents<br />

Roof-mounted radiator with<br />

integrated expansion tank<br />

<strong>Panda</strong> Generator<br />

Expansion tank<br />

(optional)<br />

<strong>Panda</strong> Generator<br />

Expansion tank<br />

<strong>Panda</strong> Generator<br />

<strong>Panda</strong> Generator<br />

23


24<br />

3. Power ComPonents<br />

Safety and Reliability<br />

All the benefits of the asynchronous generator and more....<br />

Overload protection<br />

Water-cooled<br />

Short-circuit stability<br />

Perfect sine wave<br />

Precise control<br />

No rotating coils<br />

No diodes<br />

No signal noise<br />

Highly efficient<br />

Brushless<br />

High protection rating<br />

Highest operating protection<br />

Patented (VCS) Voltage Control<br />

The <strong>Panda</strong> offers all the advantages of the classic<br />

asynchronous generator and with the patented<br />

Voltage Control System (VCS), produces control<br />

precision that cannot be beaten by a conventional<br />

synchronous generator. The excellent qualities of the<br />

controlled <strong>Panda</strong> asynchronous generator have been<br />

impressively proven in many tests over the past years.<br />

The asynchronous generator has always set high<br />

standards with regard to operational security and<br />

operational life. Therefore, the asynchronous generator<br />

is often the compulsory choice where a high degree of<br />

safety and reliability is demanded. This is of particular<br />

importance for professional applications, emergency<br />

services and technical response units.<br />

Extremely Smooth Sine Wave<br />

The alternating current’s smooth sinus wave is a noticeable<br />

characteristic of the <strong>Fischer</strong> <strong>Panda</strong> Generator. The sine waves<br />

produced by <strong>Panda</strong> asynchronous generators are very<br />

smooth and achieve outstanding results when being tested.<br />

A distorted wave form can have severe consequences on the<br />

functioning of electronic consumers such as air conditioners,<br />

charging devices, etc.<br />

Water-cooled<br />

Overload Protection<br />

<strong>Fischer</strong> <strong>Panda</strong> even warrants the rotor with a lifetime guarantee - the rotor is often the most sensitive part<br />

of other generator systems. As the components which produce the most heat are located on the stator,<br />

the asynchronous generator continues to be the best suited for water-cooling. The electrical generator is<br />

warranted with a 5-year guarantee against corrosion.<br />

The outstanding sine wave of the <strong>Panda</strong> generator


High Performance Windings<br />

AC Winding available in three different versions to suit your power needs:<br />

Single-phase Winding HP1<br />

230V - 50 Hz AC or<br />

120V / 240V - 60 Hz<br />

The HP1 is the standard version for 230V AC 50 Hz,<br />

(120 / 240V - 60 Hz). This is available up to 25 kW.<br />

From 12 kW, a three-phase version should be considered,<br />

as the <strong>Panda</strong> generator permits dissymmetrical loads up<br />

to 50% per phase.<br />

A check should always be made as to whether a<br />

DC-AC Power System would be the better solution (see<br />

DAPS DC-AC Power System) for small to middle range<br />

on-board power systems.<br />

Three-phase Windings HP3<br />

400V - 50 Hz AC or<br />

208V - 60 Hz AC<br />

The 400V three-phase winding has the highest level<br />

of efficiency and the best qualities. Also, this winding<br />

can supply single-phase AC with the appropriate phase<br />

distribution. This enables each phase to be overloaded<br />

by up to 50%. A three-phase generator should always be<br />

chosen above 25 kW (from <strong>Panda</strong> 30 NE).<br />

<strong>Panda</strong> “DVS” (Duo Voltage System) - 1- plus 3-phase<br />

The “DVS” winding is a special version consisting of two<br />

separate coils without additional costs. A 400V threephase<br />

winding is combined with a single phase winding.<br />

This permits the use of three-phase motors such as watermaking<br />

units and diving compressors.<br />

The separate one-phase winding can supply the full<br />

nominal performance of the<br />

generator without “dissymmetrical<br />

load problems” to a phase, which<br />

simplifies the electrical installation.<br />

Note: Generators with DVS<br />

windings supply only 85% of<br />

the nominal performance<br />

compared with the HP1 or<br />

HP3 windings.<br />

Dual Voltage<br />

System (DVS)<br />

- only from<br />

<strong>Fischer</strong> <strong>Panda</strong><br />

lighting<br />

satellite receivers<br />

air conditioners<br />

compressors<br />

lighting<br />

boilers<br />

ventilators<br />

ovens<br />

electric motors<br />

boilers<br />

compressors electric motors<br />

3. Power ComPonents<br />

Three Phase Single Phase<br />

Single Phase + Three Phase<br />

25


26<br />

3. Power ComPonents<br />

Complete Progamme for Vehicle Applications<br />

<strong>Fischer</strong> <strong>Panda</strong> generators are available in different versions to suit your needs<br />

<strong>Fischer</strong> <strong>Panda</strong> Generators are compactly constructed and highly suited for applications which have limited space<br />

available for installation. Generators are available for internal installation within the vehicle and external mounting on<br />

the chassis.<br />

The modular versions PVMV-N, PVM-NE and PVK-U have been designed to be installed with an external radiator. The<br />

most effective cooling can be achieved using a cooling system with a roof-mounted radiator.<br />

<strong>Panda</strong> PVMV-N<br />

Vehicle generator with sound insulation capsule, integrated water-cooled<br />

vertically mounted pre-silencer and main silencer<br />

Easy to install<br />

Requires external radiator<br />

Suitable for keel cooling on boats<br />

Suitable for internal installation<br />

Best choice, when space and length are available<br />

Water-cooled silencer completely integrated within the capsule<br />

Reinforced glass fibre (GRP) capsule is standard for models up to 12 kW<br />

Stainless steel capsule (MPL) for models from 15 kW and above<br />

<strong>Panda</strong> PVM-NE<br />

The PVM-NE is similar to the PVMV-N version except that the silencer<br />

is externally mounted on the capsule which is not water-cooled. No<br />

additional silencer is necessary. This version must be installed in a wellventilated<br />

area due to the heat absorbed by the silencer. The generator<br />

is housed within a sound insulation capsule.<br />

Suitable for internal installation<br />

Requires external radiator<br />

Easy to install<br />

<strong>Panda</strong> PVK-U<br />

<strong>Panda</strong> Vehicle Generator with internal water-cooled silencer<br />

for mounting externally on the vehicle chassis<br />

Suitable for external mounting<br />

Assembly bolts pre-fitted to housing<br />

Steel construction with a heavy duty one-piece cover<br />

Wide access hatch for easier access<br />

Water-cooled exhaust silencer mounted inside capsule<br />

No additional exhaust silencer required<br />

Requires external radiator


<strong>Panda</strong> PVK-UK<br />

<strong>Panda</strong> Vehicle Generator "Compact Construction" with integrated<br />

cooling system for mounting externally on the vehicle chassis<br />

Suitable for external mounting<br />

Assembly bolts pre-fitted to housing<br />

Steel construction with a heavy duty cover<br />

Wide access hatch for easier access<br />

Sound insulation capsule<br />

Water-cooled exhaust silencer inside capsule<br />

No additional exhaust silencer required<br />

Integrated radiator and cooling system<br />

<strong>Panda</strong> PSC<br />

These fully self-contained generators are fitted with an integrated<br />

cooling system, fuel tank and electrical cabinet.<br />

Integrated fuel tank<br />

Vertically mounted radiator (PSC-V)<br />

Horizontally mounted radiator (PSC-H)<br />

Suitable for external mounting<br />

Sound insulation capsule<br />

Water-cooled exhaust silencer inside capsule<br />

No additional exhaust silencer required<br />

Integrated radiator and cooling system<br />

<strong>Panda</strong> PSC-V<br />

3. Power ComPonents<br />

<strong>Panda</strong> PSC-H<br />

27


28<br />

4. SyStem ComponentS<br />

System Components - MultiPlus Inverter / Charger<br />

The MultiPlus efficiently combines both inverter and charger technology into one<br />

universal unit with up to 2.5 kW continuous performance. MultiPlus units can operate in<br />

parallel (up to 5 units) and can be connected to provide three-phase power to suit<br />

a wide range of voltage and performance ranges. The MultiPlus features a power-assist<br />

function which can be used to support the shore power supply.<br />

PowerControl – Dealing with limited shore, grid and generator power<br />

The MultiPlus is a very powerful battery charger and will draw a lot of current from the<br />

generator or shore side supply (almost 10 A per Multi at 230 V AC). The Phoenix Multi<br />

Control Panel can be used to govern the maximum current which can be drawn from the<br />

generator or shore supply. This enables the multi to take into account other AC loads that<br />

are connected and use the remainder for charging. This prevents the generator or shore<br />

power supply from being overloaded.<br />

Power Assist – Boosting the capacity of shore or generator power<br />

The “Power Assist” is a special feature of the MultiPlus which takes the idea of “power control” to a new dimension<br />

and allows the MultiPlus to supplement the capacity of another source. Peak power is usually only required for a short<br />

period of time, generally when starting inductive loads such as motors. If the generator or shore supply is insufficient<br />

the MultiPlus can compensate for this by adding energy from the battery for a limited period. When the load reduces<br />

the spare power is used to recharge the battery. Please note that a minimum shore current of 2A or generator capacity<br />

of 2 kW is required per MultiPlus.<br />

AC Generator / Shore power<br />

DC Domestic Battery Bank<br />

16A<br />

14A<br />

PowerAssist with 2 MultiPlus units in parallel<br />

Four stage adaptive charger and dual bank battery charging<br />

30A<br />

Electric Cooker<br />

Washing Machine<br />

Dishwasher<br />

Microwave<br />

The battery system receives a powerful charge from the main output. Depending upon batteries and conditions,<br />

software can be used to fine-tune the three-stage charge process to form a fourth stage which enables long periods<br />

of float charging. Additionally, the Multi is capable of charging a second battery using an independent trickle charge<br />

output which is intended for either the main engine or generator starter battery.


Uninterrupted AC power (UPS function)<br />

4. SyStem ComponentS<br />

Even if shore power fails or the generator is disconnected, the inverter with the Multi will automatically activate and<br />

supply the energy using the batteries. The Multi switches so fast (within 20 milliseconds) allowing computers and other<br />

sensitive electronic equipment to continue to operate without disruption. Each Multi is able to handle a current switch<br />

of 16A.<br />

Virtually unlimited power thanks to parallel operation<br />

Even higher power output is available when using multiple Multis’ installed in parallel.<br />

General<br />

Inverter<br />

Charging<br />

AC In<br />

Five parallel units: output power 12.5 kW<br />

MultiPlus<br />

12/3000/120<br />

MultiPlus<br />

24/3000/70<br />

Primary Voltage [V] 12 Volt 24 Volt<br />

Weight [kg] 18 18<br />

Dimensions HxLxW in [mm] 362x258x218 362x258x218<br />

Input voltage range [V DC] 9,5 – 17 19 – 33<br />

Output voltage (±2%) [V AC] 230 230<br />

Output Frequency (±0.1%) [Hz] 50 50<br />

Continuous output power at 25 °C [W] 2500 2500<br />

Peak power [W] 6000 6000<br />

AC Input voltage range [V AC] 187-265 187-265<br />

AC Input frequency range [Hz] 45-55 45-55<br />

Charge voltage “absorption” [V DC] 14,4 28,8<br />

Charge current house battery [A] 120 70<br />

Charge current starter battery [A] 4 4<br />

AC Out<br />

29


30<br />

4. SyStem ComponentS<br />

MultiPlus - Enhancing an AC Generator System<br />

Reducing running time, fuel consumption and increasing comfort onboard<br />

Traditionally, an AC generator is installed and started whenever power is required, however to ensure the optimal<br />

running, the generator should not operate with insufficient load or for prolonged periods with excessive (peak) loads.<br />

The cost per Watt is higher when AC power is supplied indirectly using an inverter / battery combination rather than<br />

directly from the generator. However, significant savings can still be made using indirect power, especially when there<br />

are varying periods with lower consumption.<br />

When combining the MultiPlus with a <strong>Panda</strong> AC generator, low AC demands can be covered by the batteries using<br />

the inverter within the MultiPlus. This can dramatically decrease the generator‘s running time during typical usage. The<br />

MultiPlus can combine power from the generator and battery bank to cover peak periods which may allow a smaller<br />

generator to be installed.<br />

Example 1: 7.5 kW AC Generator running whenever AC is required<br />

The typical AC requirements during a 24 hour period are shown in the example below. There is an AC demand<br />

throughout the day for 17 hours with three peak periods. The morning and lunch peaks reach 3kW and the evening<br />

peak reaches 6kW.<br />

To cover the evening peak of 6kW without overloading the generator, a 7.5kW generator would be required. The<br />

generator would be required to run for a total of 17 hours each day and 70% of the running time would require less<br />

than 15% of its full capacity.<br />

Generator potential<br />

AC from generator<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

8000 8000<br />

7000 7000<br />

Example 2: 7.5 kW AC Generator with MultiPlus (with PowerControl)<br />

Power [W]<br />

6000 6000<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

The running time can be reduced by using a generator 5000 5000and<br />

MultiPlus together. Low AC demands and the lunchtime<br />

Generator potential<br />

AC from generator<br />

Inverter / charger<br />

(above zero - battery energy is used<br />

below zero - batteries are charged)<br />

Power [W]<br />

0 0<br />

0 01 -1000<br />

8000<br />

-2000<br />

7000<br />

-3000<br />

6000<br />

12<br />

23<br />

34<br />

45<br />

56<br />

67<br />

78<br />

8 9 9101011111212131314141515<br />

16 16 17 17 18 18 19 19 20 20 21<br />

22<br />

23 24<br />

5000<br />

8000<br />

4000<br />

7000<br />

3000<br />

6000<br />

2000<br />

5000<br />

1000<br />

4000<br />

0<br />

0 1<br />

3000<br />

-1000<br />

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

2000<br />

-2000<br />

1000<br />

-3000<br />

Time [h]<br />

peak can be covered by the battery bank. The generator 4000 4000 is not required to run during these times. The generator only<br />

runs to cover the main peaks in the morning and evening 3000 3000 which reduces the running time to 5 hours. During this time<br />

the remaining AC that is produced by the generator is 2000 converted by the MultiPlus and used for battery charging (see<br />

2000<br />

where the inverter line dips below zero).<br />

1000 1000<br />

PowerControl reduces the current for battery charging at 17:30hrs for a short period during a peak demand period to<br />

prevent generator overload. The charge current begins to drop at 20:00hrs as the battery bank is almost fully charged.<br />

AC from MultiPlus<br />

Time [h]<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

-1000<br />

8000<br />

-2000<br />

7000


7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

-1000<br />

Example 3: 5kW generator with MultiPlus (with -2000 PowerControl and PowerAssist)<br />

-3000<br />

period of time. A MultiPlus 24/3000/70 can add 8000 an additional 3kW to the generator output. PowerAssist stops charging<br />

Power [W]<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24<br />

-1000<br />

-2000<br />

-3000<br />

Time [h]<br />

4. SyStem ComponentS<br />

When using the MultiPlus‘s PowerAssist, a smaller generator can cope with the same demand as in examples 1 and 2.<br />

The bi-directional inverter within the MultiPlus is able to add AC from the batteries to the output of the generator for a short<br />

at 17:30hrs where the blue line rises above 0 and draws current from the batteries to add to the output of the generator,<br />

7000<br />

allowing a smaller 5kW generator to be used.<br />

Generator potential<br />

AC from generator<br />

AC from MultiPlus<br />

Inverter / charger<br />

(above zero - battery energy is used<br />

below zero - batteries are charged)<br />

Peak Period<br />

(covered by combination of<br />

generator and batteries)<br />

Key benefits when using an AC generator with a MultiPlus<br />

Generator running times can be significantly reduced if varying AC is<br />

required throughout the day and if periods of lower demand can be<br />

covered using an inverter and batteries.<br />

The MultiPlus PowerControl function can prevent overload of the<br />

AC source (either generator or shore power) by restricting the current<br />

drawn for charging and using excess AC for charging batteries.<br />

The MultiPlus PowerAssist function can help cover peak demands by<br />

increasing total power and adding AC from batteries to the generator<br />

output.<br />

MultiPlus units can be connected in parallel to increase output or<br />

battery charging current.<br />

LESS NOISE<br />

AC available throughout the day<br />

Fuel and oil savings<br />

Reduced maintenance<br />

Prevents shore power tripping<br />

Prevents generator overload<br />

Use excess AC for charging batteries<br />

Combines battery and generator output<br />

Smaller generator could be used<br />

Scalable for optimal performance<br />

Up to 15 kW single-phase<br />

Up to 45 kW three-phase<br />

31


32<br />

4. SyStem ComponentS<br />

Shore Power Solutions 1 - up to 16A<br />

Shorepower management and PowerAssist function for requirements up to 16A<br />

One of the main benefits of being mobile is the ability to stop anywhere you want. Even if the marina or camping ground<br />

only has a limited shore power / hook-up connection, you can still draw sufficient AC power without tripping the circuit<br />

breakers. You can even charge your batteries when AC demands are low.<br />

Limited shore power and no AC load<br />

The Multi regulator is adjusted to match the<br />

4A limitation at the shore power connection to<br />

prevent the fuses from tripping. As no AC loads<br />

are turned on, the entire 4A can be used for<br />

battery charging.<br />

Limited shore power and low AC load<br />

With a low AC load only drawing 2A from the available<br />

4A is required. The remaining 2A is used for charging the<br />

battery bank. The current drawn from the shore power is<br />

still only 4A and will not cause the circuit breakers to trip.<br />

Limited shore power and medium AC<br />

load<br />

The water heater switches now on and increases the AC<br />

current demand to 10A. The Multi Control Panel limits the<br />

shore power drawn to 4A.<br />

The PowerAssist function within the MultiPlus enables the<br />

bi-directional inverter to supply the additional 6A from the<br />

battery bank. As soon as the load reduces, the battery bank<br />

will be recharged from the shore power connection.<br />

The maximum current drawn from the shore power will not<br />

exceed 4A and will not cause the circuit breakers to trip.<br />

Sufficient shore power and medium AC<br />

load<br />

When connecting to a 16A supply, the Multi Control Panel<br />

can be set to 16A. As only 10A is required by the AC system,<br />

the remaining 6A can be used for battery charging.<br />

4A<br />

4A<br />

4A<br />

16A<br />

4A<br />

2A<br />

6A<br />

6A<br />

0A<br />

2A<br />

10A<br />

10A<br />

Lighting<br />

Coffee Machine<br />

Boiler<br />

Microwave<br />

Lighting<br />

Coffee Machine<br />

Water Heater<br />

Microwave<br />

Lighting<br />

Coffee Machine<br />

Water Heater<br />

Microwave<br />

Lighting<br />

Coffee Machine<br />

Water Heater<br />

Microwave


Shore Power Solutions - 2 - above 16A<br />

Connecting 3 MultiPlus units in parallel for peak demands above 16A<br />

16A<br />

16A<br />

16A<br />

10A<br />

3A<br />

24A<br />

6A<br />

19A<br />

40A<br />

4. SyStem ComponentS<br />

The current required may quickly exceed 16A if a washing machine, dishwasher, electric cooker and air conditioning<br />

are being used. This may mean that some appliances will not be able to run simultaneously. Connecting Multi’s in<br />

parallel may be a solution if there is not enough shore power available.<br />

Shore power and medium AC load<br />

In this example 3 Multi units (1 MultiPlus with PowerAssist<br />

as master and 2 Multi units as slaves) are connected in<br />

parallel. The shore power available is 16A and Multi<br />

Control Panel is set to 16A.<br />

With a medium AC load of 6A, 10A is available for battery<br />

charging - this equates to 70A. Three Multi units in parallel<br />

can provide maximum charge of 3 x 70 = 210A.<br />

The regulator set on the MultiPlus Control Panel prevents<br />

the full amount be drawn so the shore power circuit<br />

breakers do not trip.<br />

Shore power with high AC load<br />

The required current is increased to 19A as soon as the<br />

washing machine is started. This exceeds the shore power<br />

limit. The PowerAssist function within the MultiPlus (master<br />

unit) enables the bi-directional inverter to supply the<br />

additional 3A from the battery bank.<br />

As soon the load reduces, the batteries will be recharged<br />

from the shore power connection. The maximum current<br />

drawn from the shore power will not exceed 4A and will not<br />

cause the circuit breakers to trip.<br />

Shore power and very high AC loads<br />

The power required will increase dramatically as more<br />

appliances are switched on. Now the Multi units will draw<br />

24A from the batteries which would cause them to rapidly<br />

discharge. The total discharge of the batteries will be limited<br />

as cookers and washing machines generally only require a lot<br />

of power for only short periods.<br />

Practice has proven, that a 16A shore power connection is<br />

often sufficient for most big yachts and luxury mobile homes.<br />

A larger power supply is usually required when continuous<br />

power for extensive air conditioning is needed.<br />

Water Heater<br />

Electric Hot Plate<br />

Air Conditioning<br />

Washing Machine<br />

Water Heater<br />

Washing Machine<br />

Electric Hot Plate<br />

Air Conditioning<br />

Water Heater<br />

Washing Machine<br />

Electric Hot Plate<br />

Air Conditioning<br />

33


34<br />

4. SyStem ComponentS<br />

System Components - Quattro<br />

Two AC inputs with integrated transfer switch<br />

Two AC Outputs<br />

The Quattro can be connected to two independent AC sources, for example shoreside<br />

power and a generator, or two generators. The Quattro will automatically<br />

connect to the active source.<br />

The main output has no-break functionality. A second output is live only when AC is<br />

available on one of the inputs of the Quattro. Loads that should not discharge the<br />

battery, like a water heater for example, can be connected to this output.<br />

Virtually unlimited power thanks to parallel operation<br />

Up to 6 Quattro’s can operate in parallel. Six units 24/5000/120, for example, will provide 25kW / 30kVA output<br />

power and 720 Amps charging capacity.<br />

Three-phase capability<br />

Three units can be set up for three-phase output. But that’s not all: up to 6 sets of three units can be parallel connected<br />

to provide 75kW / 90kVA inverter power and more than 2000A charging capacity.<br />

PowerControl - Dealing with smaller generators, limited shore-side or grid power<br />

The Quattro is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore<br />

side supply (16 A per Quattro at 230 VAC). A current limit can be set on each AC input. The Quattro will then take<br />

account of other AC loads and use whatever is spare for charging, thus preventing the generator or shore supply from<br />

being overloaded.<br />

PowerAssist - Boosting shore or generator power<br />

Allows the Quattro to supplement the capacity of the alternative source. Where peak power is so often required only for a<br />

limited period, the Quattro will make sure that insufficient shore or generator power is immediately compensated for using<br />

power from the battery. When the load reduces, the spare power is used to recharge the battery.<br />

Quattro 12/3000/120 24/3000/70 24/5000/120 48/5000/70<br />

AC inputs (2x) Input voltage range: 187-265 VAC<br />

Input frequency: 45 – 65Hz Power factor: 1<br />

Maximum feed through current A 50 / 30 50 / 30 2 x 30 50 / 30<br />

Inverter<br />

Input voltage range V DC 9,5 – 17 19 – 33 19 – 33 38 – 66<br />

Output (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1%<br />

Cont. output power at 25 °C (3) VA 3000 3000 5000 5000<br />

Cont. output power at 25 °C W 2500 2500 4250 4250<br />

Cont. output power at 40 °C W 2000 2000 3350 3350<br />

Peak power<br />

Charger<br />

W 6000 6000 10.000 10.000<br />

Charge voltage ‚absorption‘ V DC 14,4 28,8 28,8 57,6<br />

Charge voltage ‚float‘ V DC 13,8 27,6 27,6 55,2<br />

Storage mode V DC 13,2 26,4 26,4 52,8<br />

Charge current house battery (4) A 120 70 120 70<br />

Charge current starter battery A 4 (12V and 24V models only)<br />

1) Can be adjusted to 60 Hz; 120 V 60 Hz e 230 VAC on inverter output, on request; f Temperature too high, 2) Non linear load, crest factor 3:1


<strong>Fischer</strong> <strong>Panda</strong> 10/23 Hybrid-<strong>Energy</strong> System 10 kW<br />

AC Power and energy onboard<br />

from multiple sources:<br />

1. Generator only<br />

2. Batteries only<br />

3. Generator and batteries<br />

4. Shore power<br />

5. Shore power supported by batteries<br />

<strong>Panda</strong> 6000i<br />

Generator<br />

Shore Power<br />

Shore Power<br />

VE-Net Generator Module<br />

& Blue Power Panel<br />

Battery Bank 4x 200Ah<br />

Battery Bank 6x 200Ah<br />

Battery Voltage 24V<br />

Battery Bank Capacity 400 Ah (recommended)<br />

Continuous Power 5.5 kW (Generator)<br />

4. SyStem ComponentS<br />

Peak Power for System 10 kW (Generator + 1x Quattro)<br />

Max. Starting Power 23 kW<br />

2x Quattro<br />

24-5000-120<br />

Quattro<br />

24-5000-120<br />

<strong>Fischer</strong> <strong>Panda</strong> 15/35 Hybrid-<strong>Energy</strong> System 15 kW<br />

AC Power and energy on board<br />

from multiple sources:<br />

1. Generator only<br />

2. Batteries only<br />

3. Generator and batteries<br />

4. Shore power<br />

5. Shore power supported by batteries<br />

<strong>Panda</strong> 6000i<br />

Generator<br />

VE-Net Generator Module<br />

& Blue Power Panel<br />

Battery Voltage 24V<br />

<strong>Fischer</strong> <strong>Panda</strong><br />

Distribution Box<br />

Battery Bank Capacity 600 Ah (recommended)<br />

Continuous Power 5.5 kW (Generator)<br />

Peak Power for System 15 kW (Generator + 2x Quattro)<br />

Max. Starting Power 33 kW<br />

<strong>Fischer</strong> <strong>Panda</strong><br />

Distribution Box<br />

230V Consumers<br />

230V Consumers<br />

35


36<br />

4. SyStem ComponentS<br />

Automatic AC Transfer<br />

The <strong>Fischer</strong> <strong>Panda</strong> Automatic Transfer Unit monitors for the<br />

presence of the AC shore power supply. If the shore power supply<br />

is not available, the AC generator is automatically started.<br />

As soon as the shore power supply has been restored, the<br />

power can be manually switched back (if required) and the AC<br />

generator can be stopped.<br />

AC Shore power Connection<br />

Shore power<br />

Fail Detection<br />

AC Bus<br />

Power Transfer Unit<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

Generator Control Panel<br />

Generator Automatic Start<br />

Air Conditioning Domestic Electrical Appliances<br />

Fridges / Freezers


System Control Board<br />

Discover a whole new dimension with a “state-of-the-arttechnology”<br />

System Control Board. The modern design<br />

gives you full control. Simply touching the 8,4“ screen allows<br />

you to switch between functions.<br />

The status of devices connected to the unit are displayed on<br />

the screen and bar-type indicators show the vessel’s battery,<br />

voltage, fuel and water levels. Devices can be switched “on”<br />

and “off” via the panel. The time display can be changed<br />

according to the current time zone.<br />

The standard version features 32 DC switches. The SBC<br />

“Digibox” enables control of the start and stop functions of<br />

the <strong>Fischer</strong> <strong>Panda</strong> generator and visual information such as<br />

generator status, “AC OK“ and temperature or oil pressure<br />

failure.<br />

The extended version allows a camera to be used to monitor<br />

the boat from remote locations. The operating system allows<br />

the system and language to be easily adapted to almost<br />

any type of boat or sensor arrangement. The control also<br />

features a security identification system (RFID) to protect the<br />

boat from misuse by unauthorized persons (optional).<br />

Touch Display<br />

Digibox<br />

*) ActuAl displAy infomAtion mAy<br />

differ According to ApplicAtion<br />

Controller Boards<br />

4. SyStem ComponentS<br />

Display-Unit<br />

Unit comprises of aluminium frame; 8,4“ display; touch<br />

screen; controller board; embedded PC and aluminium<br />

housing<br />

Dimensions approx. 261mm x 210mm x<br />

65mm<br />

Weight approx. 1.5 kg<br />

Voltage Supply 12-24V<br />

Display / Measurement<br />

functions<br />

max. 12<br />

Switching Functions max. 64<br />

Data interfacing for<br />

Updates<br />

SD-Card 256MB or USB-Stick<br />

Power board DC<br />

Power board is installed separately and connected to the<br />

display with a communication cable. The basic unit contains<br />

two boards connected in series.<br />

Dimensions Approx. 403mm x 136mm x<br />

30mm<br />

Weight approx. 0,8 kg<br />

Voltage Supply 12-24V<br />

All outputs are fitted with<br />

Outputs 16/32 6 mm2 Wago connectors and with<br />

standard automobile fuses rated up<br />

to a maximum of 16A. All outputs<br />

are independent from the display<br />

and can also be operated via microswitches.<br />

Each output uses LED‘s to<br />

indicate switching and safety state.<br />

Generator Control<br />

Control of the start and stop functions of the <strong>Fischer</strong> <strong>Panda</strong><br />

generator and visual information such as generator status,<br />

“AC OK“ and temperature or oil pressure failure.<br />

37


38<br />

4. SyStem ComponentS<br />

AC Distribution Box<br />

A reliable and safe electrical supply is an absolute “must” on board every ship.<br />

The safe supply from multiple sources such as shore power,<br />

generator and inverter to each of the electrical consumers is<br />

controlled and the unit functions as the central location for circuit<br />

breakers within the AC system.<br />

Waterproof IP 65<br />

Earth leakage protection<br />

Automatic circuit breakers<br />

AC Distribution<br />

3 Inputs<br />

12 Outputs<br />

230V AC Nominal input voltage<br />

180-250 Vac ( 50 / 60 Hz )<br />

32A Nominal current inverter<br />

16A Nominal current shore<br />

40A Nominal current generator<br />

Shore Power <strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

Inverter<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Distribution BoxModel: ACD 312<br />

Air Conditioning Fridge Microwave Oven Coffee Machine Computer Hairdryer


Parallel Transfer Unit<br />

Designed for connecting two <strong>Fischer</strong> <strong>Panda</strong> AC Generators in parallel<br />

The <strong>Fischer</strong> <strong>Panda</strong> Transfer Units can be used to synchronize both<br />

generators to switch the load from one generator to another or both<br />

generators to run together and double the total power available.<br />

A range of units are available to suit varying generator types and<br />

power requirements: up to 22 kW, 40 kW, 65 kW, 85 kW and 100<br />

kW per generator. The parallel power units can be combined with<br />

the automatic AC transfer unit into a single housing on request.<br />

The parallel transfer unit does not feature load-sharing capabilities<br />

for safety reasons. Both generators are coupled and operate<br />

together as one unit. To increase operational safety both generators<br />

are shutdown if a system failure occurs.<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

Panel<br />

Parallel Transfer Unit<br />

Ac Bus<br />

Panel<br />

<strong>Fischer</strong> <strong>Panda</strong> AC Generator<br />

4. SyStem ComponentS<br />

Air Conditioning Deep Freezer Hot Plate Electric Motor Lighting<br />

Inverter<br />

39


40<br />

4. SyStem ComponentS<br />

VE.NET Connectivity<br />

Module for integrating <strong>Fischer</strong> <strong>Panda</strong> Generator into VE. Network<br />

The generator control module enables a large number<br />

of features from the <strong>Fischer</strong> <strong>Panda</strong> generator to be<br />

connected into a VE.NET power management and<br />

control network. This enables the generator to be<br />

controlled and monitored from remote locations if the<br />

VE.NET network is fitted with a GSM web module. The<br />

module includes monitoring of AC voltage, current,<br />

kilowatts and frequency, DC voltage, oil pressure, water<br />

temperature and engine speed. This information is<br />

transmitted over the VE.NET network.<br />

Auto start capability<br />

The VE.Net module adds “auto start” capability,<br />

automating the generator’s start up routine of pre-heat<br />

and cranking (until the engine starts). The module can<br />

start the generator from a VE.Net signal or hard-wired<br />

momentary or latching contacts.<br />

VE.Net Generator Module<br />

Power supply voltage range 7 - 32 V DC<br />

Maximum current consumption 30 mA / 12 V - 15 mA / 24 V<br />

INPUTS<br />

Battery Voltage 7,0 - 32,0 V<br />

AC Amperage (via external CT) 0 - 100 A<br />

AC Voltage (via external drop down transformer) 0 - 300 V<br />

Engine Coolant Temperature Determined by engine sender<br />

Engine Oil Pressure Determined by engine sender<br />

Engine Speed Magnetic Pickup 0 - 30 V pulse<br />

External Start Momentary N/O input (momentary close to start)<br />

External Stop Momentary N/O input (momentary close to stop)<br />

External Start/Stop Latching Toggle N/O input (close to start and run - open to stop)<br />

OUTPUTS<br />

Preheat Contactor 3A / 30 V DC / 250 V AC / (N/O)<br />

Start Contactor 3A / 30 V DC / 250 V AC / (N/O)<br />

Stop Contactor 3A / 30 V DC / 250 V AC / (N/O)<br />

Victron VE. NET Generator Controller<br />

Victron VE. NET Main Control Panel


VE.NET Connectivity<br />

Battery Monitor Module for VE.Net Network<br />

For effective battery management, the VE.Net battery monitor provides exact and<br />

reliable data about the state of the battery bank and prevents unwanted surprises<br />

such as suddenly low batteries. Standard information about the battery bank<br />

status is monitored and a relay which can be used to remotely start the generator<br />

or activate an alarm. The battery controller has alarms which can be adjusted to<br />

signal on low voltage, high voltage or charge state.<br />

Additional Data Acquisition<br />

Deepest discharge (Ah)<br />

Depth of last discharge (Ah)<br />

Average discharge (Ah)<br />

Number of full discharges<br />

Number of cycles<br />

Days since last full charge<br />

Cumulative Battery Amp Hours (Ah)<br />

Maximum Battery Volts (V)<br />

Minimum Battery Volts (V)<br />

VE.Net Battery Controller VBC<br />

Power supply voltage range 9 - 35 V DC<br />

Current draw 10 mA at 12V<br />

Input voltage range 9 - 35 V DC<br />

Current range with standard shunt - 500 A - +500 A<br />

Shunt current 0 - 50000 A<br />

Shunt input voltage range -50 - +50 mV DC<br />

Battery capacity 20 - 65535 Ah<br />

Operating temp. range -20 - +50°C (0 - 120°F)<br />

Resolution<br />

Voltage ± 0,01 V<br />

Current ± 0,1 A<br />

Amp hours ± 0,1 Ah<br />

State of charge (0 - 100 %) ± 1 %<br />

Time to go ± 1 min<br />

Temperature (0 - 50°C or 30 - 120°F) ± 1°C (± 1°F)<br />

Accuracy of voltage measurement ± 0,3 %<br />

Accuracy of current measurement ± 0,4 %<br />

Potential free contacts 3A / 30 V DC / 250 V AC / (N/O)<br />

4. SyStem ComponentS<br />

Victron VE. NET Battery Monitor<br />

41


42<br />

4. SyStem ComponentS<br />

Alternative System Components<br />

Power System Control Panels<br />

Cabin lights, pumps, sockets, radios, fans and heaters are just<br />

some of the DC electrical appliances fitted on board modern<br />

vehicles and boats. An electrical switching panel helps you to<br />

keep track of the status of equipment on board the vessel.<br />

The panel allows all the electrical fuses to be centrally<br />

monitored. LEDs provide a visual signal in the event of a<br />

problem. As soon as any problem is corrected the fuse<br />

distribution box can reset using the panel.<br />

Battery Monitor<br />

The installation of the battery monitor will give you the<br />

information about how much power from your batteries you<br />

really are using, when it is being used, how much is remaining<br />

and the current charging state.<br />

The battery monitor helps prevent nasty surprises such as<br />

unexpectedly flat batteries and can even be programmed to start<br />

the generator whenever the batteries require charging.<br />

Automatic AC Transfer Switch<br />

The Filax has been designed to switch sensitive loads, such as<br />

computers or modern entertainment equipment from one AC<br />

source to another.<br />

The priority source is typically a generator or shore power. The<br />

alternate source typically is an inverter.<br />

With fast switching time sensitive loads will continue to operate<br />

without disruption. The Filax is not intended to supply high power<br />

household equipment like washing machines or electric motors.<br />

Manual AC Transfer Switch<br />

A generator or inverter is required to ensure that your power<br />

system can operate independently. A manual transfer switch<br />

ensures safe switching between different power sources and<br />

prevents multiple power sources from supplying the system<br />

simultaneously.


Batteries<br />

The battery bank is probably the most important source of energy<br />

for electrical consumers required for normal operation e.g.<br />

navigation, radios, lighting and pumps.<br />

With the installation of a MultiPlus, AC can be supplied from<br />

a battery bank and a limited shore power connection can be<br />

supported to power larger devices for a limited period of time.<br />

Power is supplied without any noise because the MultiPlus and<br />

battery feature no moving parts<br />

<strong>Fischer</strong> <strong>Panda</strong> DC Power <strong>Systems</strong> have been specially developed to<br />

supply AC via a battery bank and ensure that the battery bank is<br />

efficiently charged and that there is always sufficient power available<br />

on demand. <strong>Fischer</strong> <strong>Panda</strong> Power <strong>Systems</strong> are ideal for integration<br />

with deep-cycle battery banks using AGM, GEL and Optima Spiral<br />

TM batteries.<br />

Lightweight Battery Chargers<br />

Simple, compact, efficient and intelligent: they provide an effective<br />

solution for overnight charging and maintaining smaller battery<br />

banks; ideal for plugging into an AC wall socket or connecting to<br />

a distribution box. They can also be used to maintain the ship or<br />

vehicle starter batteries.<br />

Completely encapsulated: waterproof, shockproof and ignition<br />

protected. Water, oil or dirt will not damage the Blue Power<br />

charger. The casing is made of cast aluminium and the electronics<br />

are moulded in resin.<br />

Installation Accessories<br />

Whether your power system is being installed in the engine<br />

room of a yacht, the hull of a catamaran, inside a mobile<br />

home or underneath a truck’s chassis, <strong>Fischer</strong> <strong>Panda</strong> can<br />

provide all the necessary cables, hoses, connection pieces and<br />

accessories to ensure that the system can be correctly installed.<br />

This also includes when you require specific hose and cable<br />

lengths. Service kits are also available for serving the major<br />

components such as the engine and generator.<br />

“We can supply installation kits to match<br />

your requirements - just contact us<br />

4. SyStem ComponentS<br />

43


44<br />

5. Distributors anD services<br />

Dealers & Services Germany<br />

Sorted by Postcode<br />

Autotechnik Scholz<br />

Lindenthaler Hauptstraße 27<br />

04158, Leipzig<br />

Tel.: 0341.4615160<br />

http://www.autotechnik-scholz.de<br />

WWZ GmbH Wohnmobil & Wassersport Zentrum<br />

Magdeburger Chaussee 71<br />

06193, Sennewitz/Halle<br />

Tel.: 034606-29160<br />

www.wwz-halle.de<br />

MMT Marine-Motoren-Technik<br />

Potsdammerstraße 18a<br />

14513, Teltow<br />

Tel.: 0331/8710281<br />

www.mmt-service.de<br />

Krüger & Till<br />

Unter den Linden 17<br />

14542, Werder/Havel<br />

Tel.: 03327 42424<br />

www.wassersport-werder.de<br />

Yacht- & Schiffsservice<br />

Warnow Werkstatt Warnemünde, Paap & Sohn OHG, Am Bahnhof<br />

2 a Yachthafen<br />

18119, Warnemünde<br />

Tel.: 0381 52972<br />

Motoren Recht & Böckmann GmbH<br />

Hakenstrasse 12<br />

21107, Hamburg<br />

Tel.: 040 75602813<br />

www.motrb.com<br />

YEH Engels & Kieth GmbH (Norddeutschland)<br />

Olenmoorweg 3<br />

25469, Halstenbek<br />

Tel.: +49 4101 - 40 31 19<br />

www.yeh-engels-kieth.de<br />

25469, Halstenbek bei Hamburg<br />

Tel.: +49 4101 - 40 20 59<br />

www.yeh-engels-kieth.de<br />

Thews & Weber - Yachting-Team<br />

Höllenmühle 7<br />

32351, Stemwede-Levern<br />

Tel.: 05745 300054<br />

<strong>Fischer</strong> <strong>Panda</strong> GmbH<br />

Otto Hahn Str. 40<br />

33104, Paderborn<br />

Tel.: +49 (0)5254 9202-0<br />

www.fischerpanda.de<br />

J & B Fahrzeugbau<br />

Betriebsstätte Wahlitz<br />

39175, Wahlitz<br />

Tel.: 039200-66799-7<br />

Gebrueder Ludewig GmbH & Co. KG<br />

Steeler Str. 199–207<br />

45138 , Essen<br />

Tel.: +49 201 43762-14<br />

http://www.ludewig-essen.de<br />

Bosch Car Service Glasmacher<br />

Kopernikustrasse 9<br />

50126, Bergheim<br />

Tel.: 022719959911


Greuel & Kermer GmbH & Co. KG<br />

Bleriotstraße 7<br />

50827, Köln<br />

Tel.: 0221-591220<br />

www.greuel-fahrzeugtechnik.de<br />

Dieselzentrum von Umbscheiden GmbH<br />

von-Hönefeld-Str. 4a Gewerbegebiet Ossendorf<br />

50829, Köln<br />

Tel.: 0221 956566-0<br />

www.umbscheiden.de<br />

ProVan GmbH<br />

Feldborn 3<br />

55444, Waldlaubersheim<br />

Tel.: 0049 6707 66696-13<br />

www.provan.tv<br />

Transwatt GmbH<br />

Coesterweg 41<br />

59494, Soest<br />

Tel.: 02921 9669 17<br />

http://www.transwatt.de<br />

Philippi Elektrische Systeme GmbH<br />

Neckaraue 19<br />

71686, Remseck am Neckar<br />

Tel.: 07146-8744-0<br />

www.philippi-online.de<br />

VTS Studiotechnik GmbH<br />

Am Königsholz Ost 4<br />

85411, Eglhausen Gemeinde Hohenkammer<br />

Tel.: 08166 6764-0<br />

www.vts-gmbh.com<br />

Bernds Bootsdienst<br />

Linggstraße 20<br />

88131, Lindau<br />

Tel.: 08382-6958<br />

Schiffs & Bootswerft Süß e.K.<br />

Sankt Johann 80A<br />

91056, Erlangen<br />

Tel.: 0 9131 992008<br />

www.suess-werft.de<br />

Eugen Seibold<br />

Am Kinsingwald 2<br />

94121, Salzweg<br />

Tel.: 0851-45449<br />

5. Distributors anD services<br />

45


46<br />

5. Distributors anD services<br />

Distributors & Services Worldwide<br />

Australia<br />

Power Protection Solutions Pty Ltd.<br />

P. O. Box 122, QLD 4020, Redcliffe<br />

Tel.: 0061-7-32837800<br />

www.powersolutions.com.au<br />

Austria<br />

Sportboot Center Schmitt<br />

Neuholdaugasse 52, 8010, Graz<br />

Tel.: +43- (0) 316-821910<br />

http://www.sportboote.at/index.php/ueber-uns.html<br />

Wegscheider Hermann GmbH<br />

Brixentaler Str. 54, 6300, Wörgl<br />

Tel.: +43 5332 7629212<br />

http://www.wegscheider.or.at/<br />

Diamond Marine AT<br />

Handelskai 343 / Marina Wien, A-1020 Wien<br />

Tel.: +43 1 729 23 93<br />

http://www.diamond-marine.at<br />

Bahrain<br />

<strong>Systems</strong> & Technology Enterprises<br />

13 First Floor, Com. Bldg 2931 Road 2251, 522, Barbar<br />

Tel.: +973 17691414<br />

http://www.ste.bh<br />

Belgium<br />

YSEBAERT NV<br />

Koralenhoeve 13, 2160, Wommelgem<br />

Tel.: +32 33280660<br />

www.ysebaert.be<br />

Bosnia and Herzegovina<br />

Sportboot Center Schmitt<br />

Neuholdaugasse 52, 8010, Graz<br />

Tel.: +43- (0) 316-821910<br />

http://www.sportboote.at/index.php/ueber-uns.html<br />

Brazil<br />

<strong>Fischer</strong> <strong>Panda</strong> do Brasil, Comercio<br />

de Geradores Ltda.<br />

Rua Don Bento Pickel, 493, CEP 02544-000, Sao Paulo, SP –<br />

Brazil<br />

Tel.: (55)11-2208-8344<br />

www.fischerpanda.com.br<br />

Bulgaria<br />

WaterMota SRL<br />

Bd. I.C. Bratianu, nr. 5, Constanta<br />

Tel.: +40(0)241 485545<br />

http://www.watermota.ro<br />

China<br />

<strong>Fischer</strong> <strong>Panda</strong> GmbH Beijing Representative Office<br />

Unit 503, Beijing Landmark Tower 1, 8 North Dongsanhuan<br />

Road, Chaoyang District, Beijing, China 100004<br />

Tel.: +86 10 6590 6591<br />

www.fischerpanda.de<br />

Croatia<br />

INDEL MARINE<br />

Rubesi 134, 51215, Kastav<br />

Tel.: +385-51-224 384<br />

www.fischerpanda.hr www.indelmarine.hr<br />

Cyprus<br />

Tuti Mare Trading Ltd.<br />

P. O. Box 6130, 3304, Limassol<br />

Tel.: 00357 25 431313<br />

Czech Republic<br />

Phoenix-Zeppelin, s.r.o.<br />

Lipov 72, 251 70, Modletice<br />

Tel.: 00420 - 266 015 335<br />

www.p-z.cz


Denmark<br />

Gertsen & Olufsen<br />

Savsvinget 4 , DK-2970, Hørsholm<br />

Tel.: +45 45 763 600<br />

www.g-o.dk<br />

JH-Teknik<br />

Industrivangen 18, 2635, Ishoej<br />

Tel.: +45 43735555<br />

www.43735555.dk<br />

Egypt<br />

Nautix Ltd.<br />

8a, 26th of July St., Kairo<br />

Tel.: + 2 (02 ) 2 390-2027<br />

nautix.com.eg<br />

Estonia<br />

Powerduo Oy<br />

Haikankatu 2, 21200 Raisio<br />

Tel.: +358 207 438900<br />

Finland<br />

Powerduo Oy<br />

Haikankatu 2, 21200 Raisio<br />

Tel.: +358 207 438900<br />

France<br />

Navimo Distribution SAS<br />

15 rue Ingenieur Verriere, 56100, Lorient<br />

Tel.: 0033 473 904747<br />

www.navimo.com<br />

GENHY Generation Hybride (Guillaume Barnaud)<br />

33, rue des Epinettes, 85200, MONTREUIL<br />

Tel.: +33 2 28 13 04 03<br />

ATEF CHANTIER NAVAL<br />

Zone Technique 1, 30240, Port Camargue<br />

Tel.: +33 4 66 53 44 31<br />

BARCARES YACHTING<br />

Quai du grau St. Auge, 66420, Le Barcarès<br />

Tel.: +33 4 68 86 44 88<br />

www.barcares.yachting.fr<br />

Cap Loisirs<br />

, 50100, Port Chantereyne<br />

Tel.: +33 2 33 87 58 20<br />

www.caploisirs.fr<br />

5. Distributors anD services<br />

CHANTIER NAVAL METAL MARINE<br />

Port Napoléon – Presqu’ile du Mazet, 13230, Port Saint<br />

Louis du Rhône<br />

Tel.: +33 6 20 60 56 48<br />

Code Bleue<br />

C14 La Galiote - Les Marines de Gogolin, 83310,<br />

Gogolin<br />

Tel.: +33 9 61 39 57 77<br />

www.codebleu-med.fr<br />

D2EA SARL (Pascal Gagné)<br />

12 chemin de la marjolaine, F-06530, Peymeinade<br />

Tel.: 0033 (0)4 93 66 51 49 (fixe)<br />

http://www.d2ea.fr<br />

Deal Marine<br />

48 chemin de l’aubarède - Angle allée Dany Bernard,<br />

06210, Le Cannet<br />

Tel.: 0033 (0)4 93 94 23 05<br />

www.deal-marine.com<br />

E3-Marine<br />

Port de Plaisance, 56190, Arzal<br />

Tel.: 0033 6 27 19 40 00<br />

www.e3marine.fr<br />

ECCS<br />

Quai de la Cabaude, 85100, Les Sables d Olonne<br />

Tel.: 0033 2 51 21 19 22<br />

JEAN-LUC NAUTISME<br />

7 Route de Béziers , 34410, Sauvian / Sete<br />

www.occasion-marine.fr<br />

Mecamar<br />

Le Sillon, 29570, Camaret Sur Mer<br />

Tel.: + 33 2 98 27 95 29<br />

Neoler<br />

9, Quai de L’Ile du Bac, 78700, Conflans-Sainte-Honorine<br />

Tel.: 0033 1 39 27 94 03<br />

www.neoler.com<br />

47


48<br />

5. Distributors anD services<br />

Distributors & Services Worldwide<br />

France (cont.)<br />

PK Fluvial<br />

peniche “femmy”, Ile Martinet – port de Charenton le Pont,<br />

94220, Charenton le Pont<br />

Tel.: +33 (0) 1 48 72 28 54<br />

www.pkfluvial.com<br />

TEEM Lorient<br />

1 rue d Estienne D Orves, Lorient, 56100<br />

Tel.: +33 (0)2 30 91 98 10<br />

www.teem-electronique.de<br />

TEEM Pordic<br />

17 rue Pierre et Marie Curie - Z.I., 22590 , Pordic<br />

Tel.: +33 (0)2 96 79 17 59<br />

www.teem-electronique.fr<br />

Uchimata Sailing Service SARL<br />

ZA des Minimes 3, Quai Marillac, 17000 La Rochelle<br />

Tel.: +33 (0) 5 46 52 16 42<br />

www.uchimata.fr<br />

Grand Canaries<br />

Columbus Navigation<br />

C/ San José, 30 D, 35140, Mogan de Gran Canaria<br />

Tel.: 0034-607 18 25 30<br />

Whatever Floats Your Boats S.L.<br />

Portonovo El Varadero, Locals 7 and 8, 35130, Puerto Rico,<br />

Las Palmas de Gran Canaria<br />

Tel.: +34 928 561 960<br />

http://www.paradise-marine.com<br />

Greece<br />

Ice Sea P. S.<br />

34 Possidonos Avenue, 17455, Alimos-Athens<br />

Tel.: 0030 210 9844114<br />

www.icesea.gr<br />

Hong Kong<br />

Foilborne Engineering Ltd.<br />

Unit A7-9,13/F,Veristrong Industrial Centre,34-36 Au Pui Wan<br />

Street,Fo-tan,, Shatin<br />

Tel.: 00852 2687-2988<br />

Promax Marine Limited<br />

G/F 39 Wun Sha Street,, Causeway Bay<br />

Tel.: +852-2882-1000<br />

www.promaxmarine.com<br />

Hungary<br />

KRATOS Kft.<br />

1043 Budapest, Dugonics u. 11<br />

Tel.: +36 1 231 3030<br />

www.kratos.hu<br />

India<br />

DAN KRIS Power <strong>Systems</strong><br />

G-22 , Zakaria Industrial Estate, Marol Maroshi Road. Andheri<br />

East, 400 059, Mumbai<br />

Tel.: +91 22 29250763 / 64 / 65<br />

<strong>Fischer</strong> <strong>Panda</strong> Defence <strong>Systems</strong> Pvt. Ltd.<br />

302, 16A, Uday park New Delhi – 110049<br />

Tel.: +91-9810193003<br />

<strong>Fischer</strong> <strong>Panda</strong> GmbH<br />

Otto Hahn Str. 40, 33104, Paderborn<br />

Tel.: +49 (0)5254 9202-0<br />

www.fischerpanda.de<br />

Indonesia<br />

PT. Bordtechnik International Pacific<br />

Gedung Agnesia LT. 3 R. 3/B, Jl. Pemuda No.73B , 13220,<br />

Jakarta<br />

Tel.: +62 2147881990<br />

www.bordtechnik-pacific.com<br />

Iran<br />

Afrang Motor Co.<br />

5th floor, No.2, Amini Dead end , Tour St. ,Africa Ave.,, 19176,<br />

Tehran<br />

Tel.: 0098-21-22011831<br />

Iraq<br />

Prime Trading and Industrial Services EOOD<br />

Street 192. No.1, Sofia 1747, Bulgaria<br />

Tel.: +359 2 489 7300<br />

Israel<br />

Technological Applications<br />

P.O.Box 18247, 61182, Tel Aviv<br />

Tel.: +972-3-5586279<br />

www.tec-apps.co.il


Distributors & Services Worldwide<br />

Italy<br />

Veco s.p.a.<br />

Via Cantore 6/8, 20034, Giussano (MI)<br />

Tel.: 0039 0362 35321<br />

www.veco.net<br />

Japan<br />

Dives Trading (Japan) Co.,Ltd.<br />

DDS Bldg.3F., 3-6-41 Marunouchi, Naka-ku, Nagoya, 460-<br />

0002<br />

Tel.: 0081 52 971 5700<br />

www.mmjp.or.jp/dives<br />

Korea<br />

Dives Trading (Japan) Co.,Ltd.<br />

DDS Bldg.3F., 3-6-41 Marunouchi, Naka-ku, Nagoya, 460-<br />

0002<br />

Tel.: 0081 52 971 5700<br />

www.mmjp.or.jp/dives<br />

Dong Yang Digital Co.Ltd. DYC<br />

Suit 1105, 11th Floor, Samkoo Bldg.16-49 3GA Hankang-Ro,<br />

Yongsan-Ku, Post No. 140-712, Seoul<br />

Tel.: 0082 2 705 1332<br />

www.idyd.com<br />

Kuwait<br />

Fahad Al-Sabih Gen. Trad. Co,<br />

Al Shuwaikh Ind.Area 3. Block B, Building 130, 4th Ring Road,<br />

back side of Sultan Center, P.O. Box 13022 keefain, 71951,<br />

Kuwait<br />

Tel.: 00965 24921484<br />

www.falsabih.com<br />

Lebanon<br />

Overseas Consultants<br />

P.O.Box 13-5484, C.P. 2032 3302, Beirut<br />

Tel.: 00961-1-368316<br />

Libya<br />

X S Marine<br />

26, Paul Borg Street, Attard, Malta, ATD 2632<br />

Tel.: 00356 7900 9300<br />

www.xs-marine.com<br />

Maldives<br />

MA Services Pvt. Ltd.<br />

G. Veyoge, Husnuheena Magu, Male’ 20118<br />

Tel.: (+960) 3310935<br />

http://www.maservices.com.mv<br />

Mallorca<br />

5. Distributors anD services<br />

Mo-Tech<br />

c./ Alexandre de Laborde, 1, 07011, Palma de Mallorca<br />

Tel.: 0034 971 753411<br />

Malta<br />

X S Marine<br />

26, Paul Borg Street, Attard, Malta, ATD 2632<br />

Tel.: 00356 7900 9300<br />

www.xs-marine.com<br />

Mauritius<br />

D.A.Y Marine & Services Ltd.<br />

Cnr Royal Road & Avenue des Vacoas, Tamarin<br />

Tel.: +(230) 483 80 11<br />

http://www.day-marine.com<br />

Montenegro<br />

INDEL MARINE<br />

Rubesi 134, 51215, Kastav<br />

Tel.: +385-51-224 384<br />

www.fischerpanda.hr www.indelmarine.hr<br />

Avel Yachting d.o.o.<br />

Obala Pine bb, 85320 Tivat, Montenegro<br />

Tel.: +382 69 92 74 11<br />

http://www.yacht-maintenance-montenegro.com<br />

49


50<br />

5. Distributors anD services<br />

Distributors & Services Worldwide<br />

Netherlands<br />

Barco Marine Equipment<br />

J. v/d Heydenstraat 3, 3281 NE, Numansdorp<br />

Tel.: 0031 186 6550-10<br />

www.barcomarine.nl<br />

Combi Noord Marine Equipment<br />

De Seize 1, 9001XT, GROU<br />

Tel.: (+31) 566 62 09 09<br />

http://www.combinoord.nl<br />

Cornelis Jongkind Scheepstechniek<br />

Breek 30, 1671, GE Medemblik<br />

Tel.: (+31) 227 570166<br />

www.cornelisjongkind.nl<br />

De Stille Boot ~ ElektroSloep<br />

It Bûtlân 9, 8621 DV, Heeg<br />

Tel.: +31 515 44 44 28<br />

www.destilleboot.nl<br />

Lasaulec Nautiek<br />

Kûper 4, 8447 GK, NL Heerenveen<br />

Tel.: +31 (0) 513-617140<br />

www.lasaulec.nl<br />

TOP <strong>Systems</strong> B.V.<br />

Duitslandweg 13, 2411, NT BODEGRAVEN<br />

Tel.: (+31) 172650737<br />

www.topsystems-energy.nl<br />

Heins scheepstechniek b.v.<br />

Hoorn 310, 2404 HL Alphen a/d Rijn<br />

Tel.: 0031 ( 0 ) 6- 10 89 83 54<br />

WWW.SCHEEPSTECHNIEK.COM<br />

Yachtservice Friesland<br />

De Tuije 14, 9263 PZ, Garijp<br />

Tel.: +31 (0) 511 52 20 12<br />

www.jachtservicefriesland.nl<br />

New Zealand<br />

Pacific Power <strong>Systems</strong><br />

226 B Bush Road, Auckland<br />

Tel.: 0064 9 414 4738<br />

www.pacificpower.co.nz<br />

Norway<br />

Anda-Olsen AS<br />

Breivika Industrivei 47, 6018, Aalesund<br />

Tel.: 0047-701 789 70<br />

www.anda-olsen.no<br />

Nord West Marine AS<br />

Tollbugata 6, 6002, Alesund<br />

Tel.: (47) 70 10 02 22<br />

www.nordwest.no<br />

Berema AS<br />

Berghagan 5,P.O.Box 454, 1401, Ski<br />

Tel.: 0047 64 8605-00<br />

Oman<br />

<strong>Systems</strong> & Technology Enterprises<br />

see (Bahrain)<br />

Pakistan<br />

ZENITH TECHNOLOGIES (PRIVATE) LIMITED<br />

D-90, Miran Muhammad Shah Road, KDA Scheme 1, Karachi<br />

Tel.: +9221-4313151 (3-lines)<br />

Poland<br />

El-Cab SP.z.o.o.<br />

ul. Obornicka 37, Bolechowo-Osiedle, 62-005, Owinska<br />

Tel.: 0048 61 8118600<br />

www.el-cab.com.pl<br />

Zak?ad handlowo-us?ugowy Zygmunt Z.arna<br />

Tracka 5, 10-364 Olsztyn, Polska<br />

Tel.: +48 (0) 89-532-13-28<br />

www.zarna.pl


Distributors & Services Worldwide<br />

Portugal<br />

Sereijo & Curado<br />

Rua Fradesso da Silveira No 53, 1300 - 260 Lisboa<br />

Tel.: +351 21 362 0789<br />

NEOenergia<br />

Rua Pôr do Sol, nº 6 - Armazém 3, 2735, Rio de Mouro<br />

Tel.: 00351 219 143223<br />

www.neoenergia.pt<br />

União Construtora Naval Lda<br />

Estaleiros Navais de Azurara, Apartado 296, 4481-912,<br />

Vila do Conde<br />

Tel.: +351 967 066 660<br />

www.uniaonaval.pt<br />

Romania<br />

WaterMota SRL<br />

Bd. I.C. Bratianu, nr. 5, Constanta<br />

Tel.: +40(0)241 485545<br />

http://www.watermota.ro<br />

Russia<br />

Unisail-T Ltd.<br />

Bld.39-7, Leningradskoye shosse,PO Box 176, 125212,<br />

Moscow<br />

Tel.: +7 495 6470445<br />

www.unisail.ru<br />

Admiral Ltd<br />

19 Partsjhezda 66, Volzhskiyj, Volgogradskaya<br />

Tel.: +7 8443 31 80 19<br />

admiral@vlz.ru<br />

BAFORS Engineering Ltd.<br />

P.O. Box 5589, Makarenko str. 62, microregion Staro-Baikalsk,<br />

Angarsk-21,665821 Irkutsk region<br />

Tel.: +7 908 6680777<br />

www.bafors.com<br />

Company Storm<br />

Sverdlova st. 24, Irkutsk, Russia 664011<br />

Tel.: +7 (3952) 24-09-19<br />

KOLT LTD, OOO Yacht-club<br />

Pr.Lenina,98, 353913 Novorossiysk, Krasnodarskiy reg.<br />

Tel.: +7-8617-63-22-58<br />

KVARTET Ltd<br />

Petrovskij av.9, Saint-Petersburg,197110, Russia Konstantin<br />

Bozko<br />

Tel.: +7 (812) 323-89-12, (812) 323-89-22<br />

Saudi Arabia<br />

5. Distributors anD services<br />

SAMACO MARINE<br />

P.O. BOX 11931, AL MALEK ROAD, AL NAHDAH DIST, 21463,<br />

Jeddah<br />

Tel.: 00966-2-6990064/6992300<br />

www.samaco.com.sa<br />

Serbia<br />

INDEL MARINE<br />

Rubesi 134, 51215, Kastav<br />

Tel.: +385-51-224 384<br />

www.fischerpanda.hr www.indelmarine.hr<br />

Seychelles<br />

D.A.Y Marine & Services Ltd.<br />

Cnr Royal Road & Avenue des Vacoas, Tamarin<br />

Tel.: +(230) 483 80 11<br />

http://www.day-marine.com<br />

Singapore<br />

Yacht Construction (Sea) Pte Ltd.<br />

#02-03 Eastech Blk 3016 Bedok North Avenue 4, 489947,<br />

Singapore<br />

Tel.: 0065 6542 2728<br />

www.superyachtservices.com<br />

Precision Technologies Pte Ltd.<br />

211 Henderson Road 13-02 Henderson Industrial Park,<br />

159552, Singapore<br />

Tel.: +65 6273 4573<br />

www.pretech.com.sg<br />

Slovakia<br />

Diamond Marine SK s.r.o<br />

Lichardova 1/A, 811 03 Bratislava<br />

Tel.: +421 2 456 402 82<br />

www.diamond-marine.sk<br />

Slovenia<br />

Elektro Stumpfl D.O.O.<br />

Pamece 175, 2380, Slovenj Gradec<br />

Tel.: 00386-02-8838193<br />

www.elektro-stumpfl.si<br />

51


52<br />

5. Distributors anD services<br />

Distributors & Services Worldwide<br />

South Africa<br />

Coastal Marine Import & Export CC<br />

P. O. Box 55, Kalk Bay 7990, Cape Town<br />

Tel.: 0027-21-7884686<br />

www.fischerpanda.co.za<br />

Boatbiz<br />

1 Harbour Park, Paarden Eiland Road, Paarden Eiland, Cape<br />

Town 7405<br />

Tel.: +27 (21) 511 6742<br />

www.boatbiz.co.za<br />

Spain<br />

Disvent Ingenieros S. A.<br />

c/ Equador, 77, 08029, Barcelona<br />

Tel.: +34 93 363 63 85<br />

www.disvent.com<br />

Active Diesel<br />

Tel.: +34 971 31 91 52<br />

http://www.active-diesel.com<br />

Azimut Electronics<br />

Dels Furs 50 Edificio Azimut, 46701, Gandía<br />

Tel.: (+34) 962 965 100<br />

www.azimutelectronics.es<br />

St. Lucia<br />

Regis Electronics<br />

Rodney Bay MarinaP.O. Box RB2225, West Indies<br />

Tel.: 001-758-452-0205<br />

Sweden<br />

Mitab Marin Industriteknik AB. (Ital Nordic)<br />

Grötövägen 22, 453 50, Lysekil<br />

Tel.: 0046 304 360-30<br />

www.italnordic.se<br />

INKOM, Industrikomponenter AB<br />

Gårdsvägen 4, 2 tr, SE-169 70 SOLNA<br />

Tel.: +46 8-514 844 00<br />

www.inkom.se<br />

Mastervolt Sweden AB<br />

Neongatan 6, 431 53, Mölndal<br />

Tel.: Telefon: +46 (0)31 7344750<br />

Switzerland<br />

Hamilton AG<br />

Steinackerstrasse 21, CH - 8302, Kloten<br />

Tel.: +41 44 805 20 80<br />

www.hamilton-ag.ch<br />

Taiwan<br />

KMW Marine Ltd.<br />

P.O. Box 89Heng Chun 946, Ping Tung<br />

Tel.: +886 932 822886<br />

Thailand<br />

Octopus Electrical Service Co. Ltd.<br />

20/15 Moo 2, Thepkasattri Rd,Koh Kaew, 83000, Muang<br />

Phuket<br />

Tel.: 0066-76-273379<br />

www.octopusasia.com<br />

A.L.T Inter Corporation Co., Ltd.<br />

52/1 Moo.5 Bangkruay - Sainoi Rd Bangsrithong, 11130,<br />

Bangkruay Nonthaburi<br />

Tel.: +66-2863-8941<br />

www.alt.co.th<br />

Tunisia<br />

X S Marine<br />

26, Paul Borg Street, Attard, Malta, ATD 2632<br />

Tel.: 00356 7900 9300<br />

www.xs-marine.com<br />

Turkey<br />

Ünver Elektrik Ltd.<br />

Seyrantepe Mah. Altinay cad. No:59 KAGITHANE - ISTANBUL,<br />

34418, Istanbul<br />

Tel.: 0090 212 2948393<br />

www.unverelektrik.com<br />

ELTESAN mobil Teknolojileri A.S,.<br />

Bayraktar Bulvari Nutuk Sokak No:9 Y.Dudullu 34775 ÜMRA-<br />

NIYE/ISTANBUL, 34775 TURKEY, Istanbul<br />

Tel.: +90 216 5405151-129<br />

http://www.eltesanmobil.com


Ukraine<br />

Electrical Engineering Ltd.<br />

ul. Pobedy, 15, 68001, Ilyichevsk<br />

Tel.: +38 (0482)304225<br />

www.eleng.biz<br />

Yugmotorservice LTD<br />

Skorohodova str 203,, Nikolaev, Ukraine 54042<br />

Tel.: +38 0512 24 50 24<br />

United Arab Emirates<br />

Natheer Technical Services<br />

P.O. Box 85186, Dubai<br />

Tel.: +971 4 267 4450<br />

United Kingdom<br />

<strong>Fischer</strong> <strong>Panda</strong> UK Ltd.<br />

17, Blackmoor Road, Ebblake Estate,, BH31 6AX, Verwood<br />

Dorset<br />

Tel.: 0044 1202 820840<br />

www.fischerpanda.co.uk<br />

United States<br />

<strong>Fischer</strong> <strong>Panda</strong> Generators Inc.<br />

4345 N. E. 12th Terrace, FL 33334, Oakland Park<br />

Tel.: 001 954 462 2800<br />

http://www.fischerpanda.com/locator/index.php#<br />

Venezuela<br />

L.K. Industria Nautica S.A.<br />

P.O. Box 79001, Caracas 1070-A<br />

Tel.: 0058 142701595<br />

5. Distributors anD services<br />

53


54<br />

5. Distributors anD services<br />

Caribbean Quick Reference<br />

Bahamas<br />

Machinery & <strong>Energy</strong> Ltd.<br />

5 Shirlea Road, 11039, Nassau<br />

Tel.: 242-394-2135<br />

Barbados<br />

Willies Diving & Marine<br />

Black Rock, St M, Barbados, St. Michael<br />

Tel.: +246 425-1060<br />

Bermudas<br />

Anfossi Marina<br />

17 Mill Creek Road, Pembroke<br />

Tel.: 001-441-292-8001<br />

Dominican Republic<br />

Centro Marine<br />

Avenida Andres 3, Boca Chica<br />

Tel.: 001-809 5236033<br />

Grenada<br />

ENZA Marine Ltd<br />

Prickly Bay<br />

Tel.: (473) 439-2049<br />

Grenada Marine<br />

P. O. Box 679, St. George,<br />

Tel.: 001-473-443-1667<br />

Netherlands Antilles<br />

Electec N.V.<br />

P. O. Box 929Philipsburg, St. Maarten<br />

Tel.: 00-599-544-2051<br />

President Yachts<br />

Joontji 11, Curacao<br />

Tel.: 001-5999-560-2775<br />

Puerto Rico<br />

Pro Motors Co.<br />

PMB 284 P.O Box 60401, 604 Aguadilla<br />

Tel.: 07 787-546-3464 (T3 )<br />

Nautica Distribuidora Nacional Inc.<br />

Calle Esteban Gonzales 843 92, Rio Piedras<br />

Tel.: 787-460-2126<br />

Plaza Del Varadero Inc<br />

110 Harbour Dr. # 11, 791 Humacao<br />

Tel.: 787-285-1510<br />

Trinidad and Tobago<br />

Dockyard Electrics<br />

Crews Inn Hotel & Yachting Centre, Chaguaramas<br />

Tel.: +868-634-4272<br />

www.dockyardelectrics.com<br />

Virgin Islands (Brit.)<br />

BVI Marine Management Inc.<br />

4003 Raphune Hill ,802 St.Thomas<br />

Tel.: 284-494-2938<br />

BVI Yacht Charters<br />

Port Purcell, Tortola<br />

Tel.: 284-494-9187<br />

http://www.bviyachtcharters.com/<br />

Compton Marine Services Ltd.(BVI)<br />

Wickhams Cay 2, Road Town,Tortola<br />

Tel.: 284 494 4287<br />

http://www.geocities.com/comptonmarine/<br />

Aquadoc Marine Services LTD<br />

Nanny Cay Marina , Tortola<br />

Tel.: 284-494-0305<br />

Virgin Islands (USA)<br />

Proper Yachts<br />

520 Mongoose Junction, St. Johns<br />

Tel.: 001-340-779-4445


<strong>Fischer</strong> <strong>Panda</strong><br />

Generators Inc.<br />

Florida<br />

Fort Lauderdale<br />

Little Cayman<br />

Cayman Brac<br />

Grand Cayman<br />

CAYMAN ISLANDS<br />

UNITED STATES<br />

Caribbean Sea<br />

L.K. Industria<br />

Nautica S.A.<br />

North Atlantic Ocean<br />

VENEZUELA<br />

Caracus<br />

5. Distributors anD services<br />

TRINIDAD<br />

& TOBAGO<br />

Tobago<br />

Trinidad<br />

55


<strong>Fischer</strong> <strong>Panda</strong> GmbH<br />

Otto-Hahn-Str. 40<br />

D-33104 Paderborn<br />

Germany<br />

Tel. : +49 (0)5254 9202-0<br />

Fax : +49 (0)5254 9202-550<br />

Email : info@fischerpanda.de<br />

Web : www.fischerpanda.de<br />

TM<br />

Disclaimer:<br />

The information contained here is to the best of our knowledge accurate<br />

at the date of publication. Please note that the data in this publication<br />

reflects the technical state at time of print. Dimensions apply for the sound<br />

insulation capsule only and do not include latches, fittings etc. Additional<br />

room will need to be calculated for installation to include hoses, cables<br />

and capsule mountings. Additional components or alternators may<br />

also affect capsule dimensions. Due to our policy of continual product<br />

development, we reserve the right to alter technical specifications without<br />

notice. All performance data relates to air and water temperatures of<br />

20°C. Performance reduction (approx. 1% per 100 m height and approx<br />

2% per 5°C air temperature and approx. 1% per 1°C water temperature<br />

above 20°C)<br />

Stand: 201301 Art. 71.02.01.008H

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!