zero-flux TM CurrenT<br />
SenSor DiagraMS<br />
a tyPical Zero-flux tm ct set-uP consists of the followinG comPonents:<br />
■ Sensor head(s)<br />
■ Cable between ea<strong>ch</strong> measuring<br />
head and the junction unit<br />
■ Junction unit with built-in wiring<br />
and power supply<br />
■ Cable between the junction unit<br />
and the power meter<br />
■ Power supply cable<br />
■ Power meter<br />
MACC plus with current output<br />
Ratio: 1000:1 Maximum primary current 1000Apk (600Arms)<br />
Current<br />
Current sensor MACC plus<br />
(up to 4), ea<strong>ch</strong> with<br />
control electronics<br />
Mains supply<br />
MACC plus with voltage output<br />
12<br />
Current<br />
Current sensor MACC plus<br />
(up to 4), ea<strong>ch</strong> with<br />
control electronics<br />
Mains supply<br />
Wiring<br />
Power Supply<br />
Junction unit HUB4MACC<br />
Power Supply<br />
Junction unit HUB4MACC<br />
Current<br />
4<br />
Voltage<br />
4<br />
Power Meter<br />
(Current Input)<br />
Power meter shunt =<br />
burden resistor<br />
Ratio: 10Vpk at a maximum primary current of 100Apk (70Arms), 200Apk (140Arms) or<br />
500Apk (350Arms)<br />
Wiring<br />
Burden resistors<br />
with precision<br />
amplifier<br />
Power Meter<br />
(Sensor Input)