12.1.4.2 Automatic Operation<br />
� This mode can be set using remote control and the operation is decided by remote control setting temperature,<br />
remote control operation mode, indoor intake air temperature and outdoor air temperature.<br />
� During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30<br />
seconds to detect the indoor intake and outdoor air temperature. The operation mode is decided based on below<br />
chart.<br />
� Every 30 minutes, the indoor and outdoor temperature is judged. Based on remote control setting temperature,<br />
the value of T1 will increase up to 50°F, T2 will decrease by 37.4°F and T3 will decrease up to 46.4°F.<br />
� The Auto Operation Mode shifting will take place whenever operation mode changed from Cool/Soft Dry to<br />
Heating or vice versa.<br />
12.2 <strong>Indoor</strong> Fan Motor Operation<br />
12.2.1 Basic Rotation Speed (rpm)<br />
� Manual Fan Speed<br />
[Cooling, Dry]<br />
o Fan motor’s number of rotation is determined according to remote control setting.<br />
Remote control ○ ○ ○ ○ ○<br />
Tab Hi Me+ Me Me- Lo<br />
[Heating]<br />
o Fan motor’s number of rotation is determined according to remote control setting.<br />
Remote control ○ ○ ○ ○ ○<br />
Tab Shi Me+ Me Me- Lo<br />
� Auto Fan Speed<br />
[Cooling, Dry]<br />
o According to room temperature and setting temperature, indoor fan speed is determined automatically.<br />
o The indoor fan will operate according to pattern below.<br />
o During operation, indoor fan motor may stop due to odor prevention.<br />