TP01<br />

Marc Pfeifer<br />

Roche Molecular Systems, Inc.<br />

Pleasanton, California<br />

marc.pfeifer@roche.com<br />

<strong>LabAutomation</strong><strong>2006</strong><br />

Co-Author(s)<br />

Josh Weinberger<br />

Dan Bristol<br />

Mike Takeuchi<br />

Paulette Thomas<br />

Imre Trefil<br />

Jon Nunes<br />

LeadStream – Galileo Integration Yields a Complete Process and Results Management<br />

Solution for ADME/Tox<br />

LeadStream is a fully integrated ADME/Tox screening solution, that combines role-specific automation for sample distribution and preparation,<br />

integrated LC/MS for analysis, and orchestration software for coordination of laboratory workflow. A LeadStream implementation is able<br />

to simplify the entire testing process from request to result, including end-to-end data tracking, automated data reduction and reporting.<br />

Recently LeadStream has been integrated with Galileo, a purpose built ADME/Tox LIMS designed to enhance the manual process of data<br />

analysis, review and approval. The combined workflow of these two products provides a significant improvement in data quality, processing<br />

time, and results reporting for a range of Tier 1 and Tier 2 ADME/Tox Screens.<br />

TP02<br />

Richard Ellson<br />

Labcyte<br />

Sunnyvale, California<br />

ellson@labcyte.com<br />

Co-Author(s)<br />

Jean Shieh, Labcyte Inc.<br />

Joseph Olechno<br />

Using Acoustic Droplet Ejection for Aqueous Samples – The Transfer of Bovine Serum<br />

Albumin Solutions and the Effect of Salt Concentrations<br />

We show the application of acoustic droplet ejection (ADE) to the transfer of protein solutions. Effects of buffer concentrations to ADE are<br />

measured and discussed. Precision and accuracy of transferring 5-100nL fluorescein-doped bovine serum albumin (BSA) droplets are<br />

measured with fluorescence. We show the effects on ADE of varying concentrations of different typical biological additives that are known to<br />

change viscosity and surface tension. We illustrate that ADE is only mildly affected by these changes in fluid viscosity and surface tension.<br />

The ability to precisely place sample droplets of protein solution on a solid surface or in a well significantly expands potential applications.<br />

We will show examples of arrays of nanoliter droplets of protein solutions on surfaces.<br />