23.02.2013 Views

LabAutomation 2006 - SLAS

LabAutomation 2006 - SLAS

LabAutomation 2006 - SLAS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MP35<br />

Aoife Gallagher<br />

Deerac Fluidics<br />

Dublin 2, Ireland<br />

aoife@deerac.com<br />

<strong>LabAutomation</strong><strong>2006</strong><br />

Automated Dispensation of Yttrium Oxide SPA Imaging Beads, Into 1536-Well Plates<br />

Using the Deerac Fluidics’ Equator HTS - Eight Tip Pipetting System<br />

The drive towards miniaturization within the pharmaceutical field has created a need for liquid handling technologies that accurately deliver<br />

low volume reagents to high-density well plates. GE Healthcare’s scintillation proximity assays provide an innovative approach for assay<br />

development and biochemical screening that allows the rapid and sensitive measurement of a wide variety of molecular interactions in a<br />

homogeneous system. Here we demonstrate the successful combination of the use of the Equator HTS eight tip pipetting system to<br />

dispense Streptavidin coupled Yttium Oxide (YOx) imaging beads. 2ul of YOx beads were dispensed into1536-well plates containing an<br />

excess of 3H-biotin. Plates were read on LEADseeker and analyzed for accuracy and reproducibility. CVs of 6-7% were obtained. Outliers<br />

were within spec of 10 or less per 1000 wells. These results demonstrate the efficacy of the Equator HTS with inbuilt stirred reservoir for<br />

the automation of the dispensation of YOx beads to high density plate formats.<br />

MP36<br />

Maojun Gong<br />

University of Cincinnati<br />

Cincinnati, Ohio<br />

gonglemon2@hotmail.com<br />

Co-Author(s)<br />

William R. Heineman<br />

University of Cincinnati<br />

On-Line Sample Preconcentration by Sweeping With Dodecyltrimethylammonium<br />

Bromide in Capillary Zone Electrophoresis<br />

On-line preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide<br />

(DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The<br />

DTAB below the CMC benefits the preconcentration of the oligonucleotides, while above the CMC good for hydrophobic small molecules.<br />

The factors affecting sweeping results were optimized and this method was evaluated by constructing calibration curves for thrombin<br />

aptamers. The sweeping scheme produced 112-fold sensitivity enhancement for the oligonucleotides relative to that run in the buffer<br />

without DTAB at the normal polatiry. The sweeping method developed here can be a good reinforcement of the preconcentration scheme<br />

by sweeping when less-hydrophobic analytes are analyzed or the higher separation power of MEKC is unwanted.<br />

120