neutralises. Zinc concentrations from samples taken in <strong>2006</strong>-<strong>2007</strong> were below the<br />

median of historical concentrations recorded from this discharge.<br />

47<br />

Monitoring of the tributary a further 1.9 km downstream, at its confluence with the<br />

Kahouri Stream, showed a zinc concentration below the detection limit of 0.005 g/m 3<br />

in the low flow survey conducted in April <strong>2007</strong>. This was well below the criterion of<br />

0.033 g/m 3 set by the United States Environmental Protection Agency for the<br />

protection of freshwater aquatic life in water of hardness similar to the Kahouri<br />

Stream. It was also below the Australia New Zealand (ANZECC) guideline of 0.008<br />

g/m 3 which provides 95% protection of aquatic communities in water of similar<br />

hardness.<br />

In conjunction with the water chemistry monitoring, biological monitoring was<br />

undertaken in the tributary 800 m downstream of the <strong>Taranaki</strong> Galvanizer’s<br />

stormwater discharge. The macroinvertebrate community found in this April <strong>2007</strong><br />

survey indicated no significant adverse effects from discharges to the tributary from<br />

the Stratford industrial area which included discharges from <strong>Taranaki</strong> Galvanizers.<br />

Air quality monitoring was undertaken during inspections of the site on two<br />

occasions, and although some visual emissions were observed at the site, no adverse<br />

effects including offensive or dangerous odours were noted outside the site<br />

boundary. Biennial monitoring of air quality using deposition gauges was not<br />

undertaken during the <strong>report</strong>ed period. Further deposition gauging is scheduled for<br />

the <strong>2007</strong>-2008 monitoring year.<br />

3.6.3 Evaluation of performance<br />

A tabular summary of the Company’s compliance record for the year under review is<br />

set out in Table 13 and Table 14.<br />

Table 13 Summary of performance for Consent 4064-2 to discharge emissions into air from the<br />

operation of a hot dip galvanising plant<br />

Condition requirement Means of monitoring during period under review Compliance achieved?<br />

1. Adopt best practicable option Inspections Yes<br />

2. Discharge shall not result in<br />

offensive odours beyond site<br />

boundary<br />

3. Requires galvanising process to<br />

be dry flux as far as practicable<br />

4. All items to be dry flux galvanised<br />

shall be clean and dry before hot<br />

dipping<br />

5. No alterations to plant or<br />

processes which may change<br />

nature of emissions<br />

Inspections Yes<br />

Inspections; Records from company Yes<br />

Inspections Yes<br />

Notify <strong>Council</strong> (no notification) N/A<br />

6. Optional review of consent Not exercised N/A<br />

N/A = not applicable