Data sheet - Fritz Kübler GmbH Zähl- und Sensortechnik

Data sheet - Fritz Kübler GmbH Zähl- und Sensortechnik Data sheet - Fritz Kübler GmbH Zähl- und Sensortechnik

22.02.2013 Views

Preset Counters LCD Preset Counters 1, 2, 4 or 6 Presets Codix 923 / 924 Pulse counter Functions / Count modes: Application examples CountDir + Add Roller shutter door with automatic shut-off STOP STOP UpDown + Add Automatic subtraction of faulty or reject parts from the total piece count UpUp + Add Adding up of two parallel or staggered production lines © Fritz Kübler GmbH, subject to errors and changes. 01/2012 • Count with direction mode • Difference mode • Quadrature mode quad/quad2/quad4 • Add, Sub, automatic reset • 2-input adding mode A+B • Ratio measurement A/B • Percentage difference measurement (A-B)/A x 100% • Batch counting • Totaliser (Overall total) • Multiplication and division factor (up to 99,9999) • Set value • Step or tracking preset Quad + Add Running direction and position on milling machines, Limit switch monitoring CountDir + Batch Logging of piece numbers and packing units plus control of replenishment of packing cartons Quad + Add tot Cut-to-length with overall total count and control of the machine www.kuebler.com 9

Preset Counters 10 LCD Preset Counters 1, 2, 4 or 6 Presets Codix 923 / 924 Frequency meter (Tachometer) Functions / Count modes: • A • Averaging Application examples A – B Synchro monitoring and control of two conveyor belts A/B Ratio measurement Time and Hours-run meter (Timer) Application examples InpB. InpB Interval measurement A B • A – B • A + B • A / B • (A – B) / A x 100 % (percentage display) • Quad (phase discriminator with recognition of direction) Quad Speed regulation with indication of direction (A-B)/A [%] Ratio measurement, e.g. for speed alignment FrErun Measurement of overall time from switching on the conveyor belt till switching off • Start delay • 2nd tacho input • Gate input • Multiplication and division factor (up to 99,9999) Functions / Count modes: • FrErun (Control via gate input) • Totaliser (Overall total) InpA. InpB Run-time measurement • Auto (Start via Reset, Stop at Preset) • InpB.InpB (Start with first edge at InpB., Stop with second edge InpB.) • InpA. InpB (Start with InpA., Stop with InpB.) Auto Time-controlled production line • Batch counting • Set value • Step or tracking preset www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 01/2012 STOP

Preset Counters<br />

LCD Preset Counters 1, 2, 4 or 6 Presets<br />

Codix 923 / 924<br />

Pulse counter<br />

Functions / Count modes:<br />

Application examples<br />

CountDir + Add<br />

Roller shutter door with automatic shut-off<br />

STOP<br />

STOP<br />

UpDown + Add<br />

Automatic subtraction of faulty or reject parts from the<br />

total piece count<br />

UpUp + Add<br />

Adding up of two parallel or staggered production lines<br />

© <strong>Fritz</strong> <strong>Kübler</strong> <strong>GmbH</strong>, subject to errors and changes. 01/2012<br />

• Count with direction mode<br />

• Difference mode<br />

• Quadrature mode quad/quad2/quad4<br />

• Add, Sub, automatic reset<br />

• 2-input adding mode A+B<br />

• Ratio measurement A/B<br />

• Percentage difference measurement (A-B)/A x 100%<br />

• Batch counting<br />

• Totaliser (Overall total)<br />

• Multiplication and division factor (up to 99,9999)<br />

• Set value<br />

• Step or tracking preset<br />

Quad + Add<br />

Running direction and position on milling machines,<br />

Limit switch monitoring<br />

CountDir + Batch<br />

Logging of piece numbers and packing units plus control of<br />

replenishment of packing cartons<br />

Quad + Add tot<br />

Cut-to-length with overall total count and control of the machine<br />