Download - Little, Big Racing
Download - Little, Big Racing Download - Little, Big Racing
R&S Business Unit Automotive 3.2 Capture / acquisition files / options / manual Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550 Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533 Email : guest@digitek.it - Internet : http://w w w .digitek.it Select Capture / acquisition files / options tab to display the following window. DATAVIEW Pg. 24/133 The entire capture system is based around the possibility of connecting to 4 different vehicles, each vehicle having a known driver. These are referred to as Car_1 to Car_4. This is the default setting for Data View Choose - Manual Cannot be edited in manual mode Cannot be edited in manual mode Used for ‘off ground’ testing of the car, accumulated distance not recognised. It is recommended to leave at 0 Run recognition - Whenever a new Run is incremented the download process will create a completely new and separate data file. If switched off, all data downloads from that logger will be included within the same file. Car recognition – When switched off, the Alias and identification of the logger is not considered. Note: • In this manual mode the user is given full control over data file naming, file locations and device connection. • Device recognition is not featured in this manual mode. data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive 3.3 Capture / acquisition files / Options / Run System Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550 Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533 Email : guest@digitek.it - Internet : http://w w w .digitek.it Select Capture / acquisition files / options tab to display the following window. DATAVIEW Pg. 25/133 The entire capture system is used to automatically manage the data storage, file naming and tagged data. A file tree structure will be created for you as shown at the bottom of this page. Run recognition - Whenever a new Run is incremented the download process will create a completely new and separate data file. If switched off, all data downloads from that logger will be included within the same file. Car recognition – When switched off, the Alias and identification of the logger is not considered. These folders are created from the ‘Alias’ name of the logger Choose - Automatic Select the PC communication method you are using Select this to ensure automatic device recognition Used for ‘off ground’ testing of the car, accumulated distance not recognised. It is recommended to leave at 0 This folder group is created from the default download folder as defined in section 6.4 This ‘bench’ folder is created from the ‘Track’ choice in ‘Acquisition files / session’ – More information can be found in section 3.6 This ‘test’ folder is created from the ‘Session’ choice in ‘Acquisition files / session’ – More information can be found in section 3.6 data view_std_manual v1.4.doc Digitek Spa Digitek Spa
- Page 1 and 2: R&S Business Unit Automotive Via L.
- Page 3 and 4: R&S Business Unit Automotive 12.3..
- Page 5 and 6: R&S Business Unit Automotive Via L.
- Page 7 and 8: R&S Business Unit Automotive Via L.
- Page 9 and 10: R&S Business Unit Automotive Via L.
- Page 11 and 12: R&S Business Unit Automotive Via L.
- Page 13 and 14: R&S Business Unit Automotive 2. Dat
- Page 15 and 16: R&S Business Unit Automotive Via L.
- Page 17 and 18: R&S Business Unit Automotive Via L.
- Page 19 and 20: R&S Business Unit Automotive 2.4 In
- Page 21 and 22: R&S Business Unit Automotive 2.6 In
- Page 23: R&S Business Unit Automotive 3.1 Ca
- Page 27 and 28: R&S Business Unit Automotive 3.5 Ca
- Page 29 and 30: R&S Business Unit Automotive 3.7 Ca
- Page 31 and 32: R&S Business Unit Automotive 3.9 Ca
- Page 33 and 34: R&S Business Unit Automotive 4.1 -
- Page 35 and 36: R&S Business Unit Automotive Via L.
- Page 37 and 38: R&S Business Unit Automotive 4.4 -
- Page 39 and 40: R&S Business Unit Automotive Via L.
- Page 41 and 42: R&S Business Unit Automotive Via L.
- Page 43 and 44: R&S Business Unit Automotive 5.1 -
- Page 45 and 46: R&S Business Unit Automotive 5.3 -
- Page 47 and 48: R&S Business Unit Automotive 6. Gen
- Page 49 and 50: R&S Business Unit Automotive 6.2 -
- Page 51 and 52: R&S Business Unit Automotive 6.4 -
- Page 53 and 54: R&S Business Unit Automotive 7. Dat
- Page 55 and 56: R&S Business Unit Automotive 7.2 -
- Page 57 and 58: R&S Business Unit Automotive 7.4 -
- Page 59 and 60: R&S Business Unit Automotive 7.6 -
- Page 61 and 62: R&S Business Unit Automotive 7.8 -
- Page 63 and 64: R&S Business Unit Automotive 7.10 -
- Page 65 and 66: R&S Business Unit Automotive 7.12 -
- Page 67 and 68: R&S Business Unit Automotive 7.13 -
- Page 69 and 70: R&S Business Unit Automotive 7.15 -
- Page 71 and 72: R&S Business Unit Automotive 7.17 -
- Page 73 and 74: R&S Business Unit Automotive 8. Ope
R&S Business Unit Automotive<br />
3.3 Capture / acquisition files / Options / Run System<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / options tab to display the following window.<br />
DATAVIEW Pg. 25/133<br />
The entire capture system is used to automatically manage the data storage, file naming and tagged data. A file tree<br />
structure will be created for you as shown at the bottom of this page.<br />
Run recognition - Whenever a new Run is incremented the download process will create a completely new and<br />
separate data file. If switched off, all data downloads from that logger will be included within the same file.<br />
Car recognition – When switched off, the Alias and identification of the logger is not considered.<br />
These folders are created from the<br />
‘Alias’ name of the logger<br />
Choose - Automatic<br />
Select the PC communication method you are using<br />
Select this to ensure automatic device recognition<br />
Used for ‘off ground’ testing of the car,<br />
accumulated distance not recognised.<br />
It is recommended to leave at 0<br />
This folder group is created from the default download folder as<br />
defined in section 6.4<br />
This ‘bench’ folder is created from the ‘Track’ choice in ‘Acquisition<br />
files / session’ – More information can be found in section 3.6<br />
This ‘test’ folder is created from the ‘Session’ choice in ‘Acquisition<br />
files / session’ – More information can be found in section 3.6<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa