Download - Little, Big Racing

Download - Little, Big Racing Download - Little, Big Racing

littlebigracing.com
from littlebigracing.com More from this publisher
21.02.2013 Views

R&S Business Unit Automotive 3.2 Capture / acquisition files / options / manual Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550 Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533 Email : guest@digitek.it - Internet : http://w w w .digitek.it Select Capture / acquisition files / options tab to display the following window. DATAVIEW Pg. 24/133 The entire capture system is based around the possibility of connecting to 4 different vehicles, each vehicle having a known driver. These are referred to as Car_1 to Car_4. This is the default setting for Data View Choose - Manual Cannot be edited in manual mode Cannot be edited in manual mode Used for ‘off ground’ testing of the car, accumulated distance not recognised. It is recommended to leave at 0 Run recognition - Whenever a new Run is incremented the download process will create a completely new and separate data file. If switched off, all data downloads from that logger will be included within the same file. Car recognition – When switched off, the Alias and identification of the logger is not considered. Note: • In this manual mode the user is given full control over data file naming, file locations and device connection. • Device recognition is not featured in this manual mode. data view_std_manual v1.4.doc Digitek Spa Digitek Spa

R&S Business Unit Automotive 3.3 Capture / acquisition files / Options / Run System Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550 Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533 Email : guest@digitek.it - Internet : http://w w w .digitek.it Select Capture / acquisition files / options tab to display the following window. DATAVIEW Pg. 25/133 The entire capture system is used to automatically manage the data storage, file naming and tagged data. A file tree structure will be created for you as shown at the bottom of this page. Run recognition - Whenever a new Run is incremented the download process will create a completely new and separate data file. If switched off, all data downloads from that logger will be included within the same file. Car recognition – When switched off, the Alias and identification of the logger is not considered. These folders are created from the ‘Alias’ name of the logger Choose - Automatic Select the PC communication method you are using Select this to ensure automatic device recognition Used for ‘off ground’ testing of the car, accumulated distance not recognised. It is recommended to leave at 0 This folder group is created from the default download folder as defined in section 6.4 This ‘bench’ folder is created from the ‘Track’ choice in ‘Acquisition files / session’ – More information can be found in section 3.6 This ‘test’ folder is created from the ‘Session’ choice in ‘Acquisition files / session’ – More information can be found in section 3.6 data view_std_manual v1.4.doc Digitek Spa Digitek Spa

R&S Business Unit Automotive<br />

3.3 Capture / acquisition files / Options / Run System<br />

Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />

Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />

Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />

Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />

Select Capture / acquisition files / options tab to display the following window.<br />

DATAVIEW Pg. 25/133<br />

The entire capture system is used to automatically manage the data storage, file naming and tagged data. A file tree<br />

structure will be created for you as shown at the bottom of this page.<br />

Run recognition - Whenever a new Run is incremented the download process will create a completely new and<br />

separate data file. If switched off, all data downloads from that logger will be included within the same file.<br />

Car recognition – When switched off, the Alias and identification of the logger is not considered.<br />

These folders are created from the<br />

‘Alias’ name of the logger<br />

Choose - Automatic<br />

Select the PC communication method you are using<br />

Select this to ensure automatic device recognition<br />

Used for ‘off ground’ testing of the car,<br />

accumulated distance not recognised.<br />

It is recommended to leave at 0<br />

This folder group is created from the default download folder as<br />

defined in section 6.4<br />

This ‘bench’ folder is created from the ‘Track’ choice in ‘Acquisition<br />

files / session’ – More information can be found in section 3.6<br />

This ‘test’ folder is created from the ‘Session’ choice in ‘Acquisition<br />

files / session’ – More information can be found in section 3.6<br />

data view_std_manual v1.4.doc Digitek Spa Digitek Spa

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!