Download - Little, Big Racing
Download - Little, Big Racing
Download - Little, Big Racing
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 1/133<br />
– v1.20 Onwards<br />
Revision 1.1<br />
Digitek S.p.A.<br />
via L. Romagnoli 24 - 41033<br />
CONCORDIA s/S (Modena)<br />
Italy<br />
tel. +39 535 57711<br />
fax +39 535 54550<br />
web page: http://www.digitek.it<br />
e-mail: guest@digitek.it<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 2/133<br />
INDEX<br />
1.0.............. Introduction<br />
7.2 ............. Restore laps<br />
1.1.............. Overview<br />
7.3 ............. Edit properties / header<br />
1.2.............. PC requirements<br />
7.4 ............. Edit properties / comment<br />
1.3.............. USB key and driver installation<br />
7.5 ............. Edit properties / session<br />
1.4.............. Installation – Data View<br />
7.6 ............. Edit properties / car<br />
1.5.............. Upgrades<br />
7.7 ............. Edit properties / constants<br />
1.6.............. Communication / Ethernet<br />
7.8 ............. Edit properties / offsets<br />
1.7.............. Communication / Ping<br />
7.9 ............. Edit properties / record<br />
2.0.............. Data View – Overview<br />
7.10 ........... Edit / Channel info<br />
2.1.............. Initial setup / lap define<br />
7.11 ........... Tools / Search laps<br />
2.2.............. Initial setup / Miscellaneous / Distance<br />
7.12 ........... Data browser layout<br />
2.3.............. Initial setup / Miscellaneous / special channels 7.13 ........... Export / DTX<br />
2.4.............. Initial setup / Miscellaneous / circuit compute 7.14 ........... Export / DTX channels<br />
2.5.............. User configuration<br />
7.15 ........... Export / Ascii<br />
2.6.............. Message history<br />
7.16 ........... Export / Binary<br />
3.0.............. Capture configuration<br />
3.1.............. Capture / setup acquisition<br />
3.2 Capture / acquisition files / Options / manual<br />
3.3.............. Capture / acquisition files / Options / Run sys<br />
3.4.............. Capture / acquisition files / Car<br />
7.17 ........... Channel browser – display<br />
7.18 ........... Channel browser – options<br />
8.0 ............. Open data - overview<br />
8.1 ............. Data selection<br />
8.2 ............. Data comparison<br />
3.5.............. Capture / acquisition files / Destination files 9.0 ............. Scaling<br />
3.6.............. Capture / acquisition files / Session<br />
9.1 ............. Automatic<br />
3.7.............. Capture / acquisition files / offsets<br />
9.2 ............. Parameters<br />
3.8.............. Capture / acquisition files / user record<br />
9.3 ............. Parameters / run average<br />
3.9.............. Capture / acquisition files / constants<br />
9.4 ............. Parameters / frequency filters<br />
4.0.............. <strong>Download</strong> overview<br />
9.5 ............. Local scaling<br />
4.1.............. Memory – Shark<br />
10.0 ........... Alarms<br />
4.2.............. Memory – Cobra<br />
10.1 ........... Alarm window<br />
4.3.............. Manual download – Manual system<br />
4.4.............. Manual download – Run system<br />
4.5.............. Automatic download – Manual system<br />
4.6.............. Automatic download – Run system<br />
11.0 ........... Graph window<br />
11.1 ........... New / load / swap<br />
11.2 ........... Page layout<br />
11.3 ........... Add / remove channel<br />
5.0.............. Connection tools<br />
11.4 ........... Properties – Page<br />
5.1.............. Clear data<br />
11.5 ........... Properties – channel<br />
5.2.............. Re-start<br />
11.6 ........... Time / Distance<br />
5.3.............. Show devices & Alias<br />
11.7 ........... Shift<br />
5.4.............. Show laps table<br />
11.8 ........... Info<br />
6.0.............. General setup / graphs<br />
11.9 ........... Max / Min<br />
6.1.............. General setup / data RX<br />
11.10 ......... Cursor<br />
6.2.............. General setup / Colours<br />
11.11 ......... Search<br />
6.3.............. General setup / Search<br />
11.12 ......... Zoom<br />
6.4.............. General setup / Miscellaneous<br />
11.13 ......... Snap<br />
7.0.............. Data file management<br />
12.0 ........... XY window<br />
7.1.............. Delete laps<br />
12.1 ........... New / load / swap<br />
12.2 ........... Page layout<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
12.3............ Properties – Window<br />
12.4............ Properties – Channel<br />
12.5............ Manual scaling<br />
12.6............ Manual positioning<br />
12.7............ Interpolation<br />
12.8............ Best Fit<br />
13.0............ XYZ window<br />
13.1............ New / load / swap<br />
13.2............ Page layout<br />
13.3............ Properties – Window<br />
13.4............ Properties – Channel & Manual scale<br />
13.5............ Interpolation<br />
13.6............ Best fit<br />
13.7............ Z Scale<br />
13.8............ Zoom<br />
13.9............ Rotate<br />
14.0............ Histogram window<br />
14.1............ New / load / swap<br />
14.2............ Page layout<br />
14.3............ Properties – Window<br />
14.4............ Properties – X scale<br />
14.5............ Properties - % scale<br />
15.0............ Trend window<br />
15.1............ New / load / swap<br />
15.2............ Page layout<br />
15.3............ Properties – Window<br />
15.4............ Properties - Channel<br />
16.0............ Lap report window<br />
16.1............ New / load / swap<br />
16.2............ Page layout<br />
16.3............ Properties<br />
16.4............ Export as text<br />
17.0............ Circuit window<br />
17.1............ New / load / swap<br />
17.2............ Page layout<br />
17.3............ Properties<br />
17.4............ Marker<br />
17.5............ Mapping – see section 20<br />
17.6............ Computation / saving<br />
18.0............ PSD window<br />
18.1............ New / load<br />
18.2............ Page layout<br />
18.3............ Properties<br />
19.0............ Numeric<br />
19.1............ New / load<br />
19.2............ Page layout<br />
19.3............ Export as text<br />
20.0............ Mapping - overview<br />
20.1............ Setup<br />
20.2............ Manual definition<br />
20.3............ Automatic definition / Throttle<br />
20.4............ Automatic definition / lateral G<br />
20.5............ Insert / remove point<br />
20.6............ Load / save<br />
20.7............ Show split time<br />
20.8............ Show map report<br />
20.9............ Show histogram<br />
20.10.......... Show table IN-MED-OUT<br />
20.11.......... Show table MED<br />
20.12.......... Zoom map<br />
20.13.......... Circuit mapping display<br />
21.0............ Layout – overview<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 3/133<br />
21.1 ........... loading & saving<br />
21.2 ........... Configuration bar – see section 26.1<br />
22.0 ........... Real time telemetry<br />
22.1 ........... Hardware & setup<br />
22.2 ........... Graph<br />
22.3 ........... Diagnostic<br />
22.4 ........... Alphanumeric<br />
22.5 ........... Circuit / linking<br />
22.6 ........... Activate<br />
22.7 ........... Data files<br />
23.0 ........... Mathematical channels (Virtual) - Overview<br />
23.1 ........... Creating new / naming<br />
23.2 ........... Load / save<br />
23.3 ........... Functions<br />
23.4 ........... Operators<br />
23.5 ........... File constants<br />
23.6 ........... Conversions<br />
23.7 ........... Constants / variables<br />
23.8 ........... Export<br />
23.9 ........... Sort<br />
24.0 ........... Miscellaneous functions<br />
24.1 ........... KUS – Overview / configuration<br />
24.2 ........... Conditional channels<br />
24.3 ........... Search T1<br />
25.0 ........... Print<br />
25.2 ........... Adding / remove notation<br />
25.3 ........... Print setup<br />
26.0 ........... Tool bar<br />
26.1 ........... Configuration bar<br />
26.2 ........... User bar<br />
26.3 ........... Data header<br />
26.4 ........... DLM information<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 4/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 5/133<br />
1. Introduction<br />
This section covers all of the information you will need to initiate work with Data View. All features covered by this<br />
manual are applicable to both the Cobra and the Shark data logging systems, unless the section specifies<br />
otherwise.<br />
Each computer must be fitted with a USB protection device called DK-Lock before data view will operate.<br />
1.1 Overview<br />
The Data View software tool is a high level analysis tool, as well as acting as the hub for control of real time<br />
telemetry and data export.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 6/133<br />
1.2 PC requirements<br />
The system is able to function on any modern PC running either Windows2000 or Windows XP, our personal<br />
preference is for WindowsXP. To cover all eventualities your PC should have the following software/hardware<br />
systems installed:<br />
o 10/100BaseT Ethernet port with Microsoft protocol TCP/IP installed<br />
o RS232 – Serial port which can be used for certain programming operations<br />
o Type II PCMCIA card slot (Shark system only)<br />
o USB port<br />
o Microsoft Internet Explorer 4 or later (ensure this is set to Work Online)<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 7/133<br />
1.3 USB key installation.<br />
For your computer to recognise and function with the DK-Lock protection key it is first necessary to install the device<br />
USB drivers.<br />
From the Hardlock folder on your system CD, run the hldrv32.exe file, follow the installation in the normal way.<br />
Insert your DK-Lock key, Windows should find the new software without problem.<br />
To check the correct installation and recognition of your key, refer to Start / settings / control panel / system /<br />
hardware / device manager / Universal serial bus controllers. The key will be denoted by the name Alladin USB key<br />
There have been cases of incompatibility Windows XP ® Service Pack2 operating system. In this case, it is needed to<br />
manually install the custom drivers by the following steps:<br />
- run the installation file HASPUserSetup.exe<br />
- copy the file hlvdd.dll to C:\WINDOWS\system32<br />
Note: These files are located on your system CD under the Hardlock menu<br />
Note: For this manual installation the DK-Lock key must be fitted to the PC.<br />
IMPORTANT – Always make a system back or restore point up before any installation process<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 8/133<br />
1.4 Installation<br />
Insert the system CD and under the Data View folder Run the Setup.exe file to install the software. This will create<br />
both a desktop icon and a shortcut under Start / Programs / Digitek Corse / Data View<br />
If you have been given a set of pre-defined system files, they can be manually copied to the folder.c:\dataview\setup<br />
You will also receive a set of files marked as CLL, LPS and TPX which will be unique to your system, these should<br />
be copied manually into the folder c:\ TableManager ETH\tables.<br />
If you have not already done so, you will also need to install a program called DK-Link which is also located on your<br />
system CD in the Dklink folder, run the setup.exe. The DK-Link program should be running in minimised mode<br />
whenever you need to communicate with any logger. See section 1.6<br />
IMPORTANT – Always make a system back or restore point up before any installation process<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 9/133<br />
1.5 Upgrades<br />
Due to ongoing development of this software you will periodically be sent an upgrade version. This can be installed<br />
over the top of an existing installation and will not overwrite any of your customised system files.<br />
IMPORTANT – Always make a system back or restore point up before any installation process<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 10/133<br />
1.6 Communication – Ethernet<br />
To activate any communication session between a logger and your PC it is first necessary to have both the PC and<br />
the logger working within a similar IP network group.<br />
The default IP setting of your data logger will be written on the documentation, which is sent with it. To change your<br />
computer IP setting, select: Start/settings/network connections – select the Local Area Connection / Internet<br />
Protocol TCP/IP to display the IP properties as shown here.<br />
You only need to change the IP address and the Subnet mask, all other properties are unnecessary. Press Ok to<br />
accept the changes. The IP shown in this picture is only an example and should not be copied.<br />
For users who need to change the IP of the data logger to suit a fixed network IP, we have specific re-programming<br />
tools for this purpose, contact your dealer.<br />
Understanding IP addresses.<br />
There are 3 significant lines to the IP Address.<br />
• Top line is the IP Address which has 4 sets of 8bit values separated by a dot eg: 196.168.10.10<br />
• Middle line is the Subnet mask which is typically 255.255.0.0 or 255.255.255.0<br />
• The default gateway is unimportant.<br />
The IP Address is split up into 2 sections known as the Network IP and the Host. To determine which part of the IP<br />
Address relates to which section (Network IP or Host) it is necessary to look at the subnet mask.<br />
Subnet mask Example 1<br />
A Subnet mask of 255.255.0.0 means that the first 2 parts of the IP address are Network IP and the second 2<br />
parts are Host<br />
Subnet mask Example 2<br />
A Subnet mask of 255.255.255.0 means that the first 3 parts of the IP address are Network IP and only the last<br />
part is the Host<br />
For PC’s or loggers to communicate freely on the same local network the Network IP and the Subnet mask must<br />
be the same. Individual data loggers or PC identity is defined by the value of the Host.<br />
The Value of the Host is an 8 bit number which is 0-255. In reality you are only able to use numbers from 1 to 254.<br />
Examples.<br />
Address – 192.168.10.18<br />
Subnet – 255.255.0.0<br />
To add a logger to this Network group you can program the logger with the following:<br />
Address – 192.168.10.1 to 254 as long as it is not 18 or<br />
Address – 192.168.1 to 254 as long as it is not 10.18<br />
Basically you are using the same Network IP and only making a change to the Host to define individual identity.<br />
You will see that a subnet mask of 255.255.255.0 gives a maximum possible number of hosts of only 255. A<br />
subnet mask of 255.255.0.0 gives a maximum number of hosts of 255 x 255 = 65,000.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 11/133<br />
The Network IP can be any number at all as long as it falls between 1 to 254 for each of it’s 3 possible parts.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 12/133<br />
1.7 Communication – Ping – DK-Link<br />
Once installed DK-Link may be started from Start/programs/digitek Corse/DK-Link. It can also be Run from Table<br />
Manager by selecting Network / Ping. IMPORTANT - Without this program running it will be impossible to<br />
communicate with any data logger.<br />
With a data logger is connected with power on, and both the logger and PC are operating in the same Network IP<br />
range, DK-Link should look like this.<br />
In this case there is a data logger of serial number Shark_003. The type of the logger is Shark, and the current Alias<br />
is not present and indicated by the /............... To learn more about Alias, refer to section 1.4c of the table manager<br />
manual.<br />
If for any reason the data logger is not seen by DK-Link the window will look like this. It will also appear to ‘blink’<br />
every few seconds as the screen automatically refreshes itself by ‘Pinging’ the network.<br />
In this case of no communication check the following.<br />
o Power supply to the data logger<br />
o Code Load is not connected with ground<br />
o The Key input is switched to 12v (Shark system only)<br />
o The Ethernet connection wiring is correct<br />
o TCP/IP is installed on your computer<br />
o There are no conflicts or problems with your network card<br />
o The IP of data logger is known and the PC - IP address is set accordingly<br />
o Internet Explorer 4.0 or later must be installed<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2. Data View – Overview<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 13/133<br />
The Data View analysis software is generic and is able to perform a wide range of functions, not all of which are<br />
required by the system you are using. For this reason there is a small amount of initial setup and configuration work<br />
required to tailor it to your needs.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.1 Initial setup / Lap definition<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 14/133<br />
This function will search the incoming data for a specified channel to indicate the beginning or end of lap. This<br />
channel is typically Time or Space (lap distance).<br />
Without this setting the start/end of lap will be decided from the second where the lap beacon signal is seen. For<br />
comparison operations it is vital to align the compared data as accurately as possible.<br />
Both the Time and Space channels of your logger will return to zero when the lap beacon is seen. Either may be<br />
used to define the laps, but it is recommended that Time is used as it does not rely on any external measurement to<br />
generate its signal. The Time should be samples at least 100Hz<br />
Select Utility / Define laps / Configure to display this window.<br />
Typically the lap will start when the<br />
channel returns to zero, you are<br />
however given the possibility to<br />
move this<br />
Press to open the Channel<br />
browser, double click to<br />
select your channel<br />
Press Ok to accept changes and<br />
close the window.<br />
The lap definition data source also needs to be specified, select Setup / General / DataRX tab to display this<br />
window. Double click the Lap Definition to open the sub-window<br />
Double click to open the sub window.<br />
Ensure that both the Ethernet and the<br />
Real Time boxes are ticked.<br />
Press Ok to accept<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 15/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.2 Initial setup / Miscellaneous / Distance<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 16/133<br />
The miscellaneous configuration plays a vital role within Data View and must be configured correctly before many of<br />
the functions will operate correctly. Select Configure / Miscellaneous to open this window.<br />
Distance alignment. He fundamental problem when comparing any two data sets is to ensure that each piece of<br />
data is occurring at the same place on the track. The start of the lap is very accurately defined by the lap beacon,<br />
from this point forward the vehicle position is derived from the wheel speed inputs to give a distance (Space<br />
channel). The Space channel is automatically re-set to zero at the start of the lap and accumulates upwards to<br />
reach a maximum as the vehicle passes in front of the lap beacon again.<br />
Presuming there are no speed signal irregularities, a fixed length of test track will produce a measured distance with<br />
a degree of variation. This variation can be considerable if there are a lot or corners and a different driving line is<br />
used for each piece of data.<br />
The only solution is to fix the data to 2 known values, one being the beginning at zero meters and the other being<br />
the end of lap distance from the first comparison lap selected. Using this fixed range, all comparison data is either<br />
stretched or compressed in distance to make a perfect fit.<br />
Skip distance alignment – Use if comparing data of significant length variation.<br />
Align to maximum distance – Uses the maximum length of the first comparison data selected.<br />
Align to minimum distance - Uses the minimum length of the first comparison data selected.<br />
Align to average distance - Uses the average length of all comparison data<br />
Align to – You define the distance in meters<br />
Press to open the Channel browser, double click to select your<br />
Space channel – Choose a channel which contains your vehicle<br />
distance is meters<br />
Leave blank – decimals are not supported or required<br />
See notes below – ref distance alignment<br />
Always leave active – This feature improves the visualisation of data<br />
when the X axis of a graph is set to Distance. See notes below.<br />
Max difference – Define a permissible tolerance, which is acceptable for the alignment process. If your data<br />
exceeds this limit you will be prompted with a warning and offered the choice to align or not.<br />
Exclude test laps – The alignment process will only be carried out with data containing a beacon > beacon<br />
structure.<br />
Distance interpolation – All data is captured with reference to a time base (Hz). The distance resolution is however<br />
only 1m, this means there may be many actual measuring points within each meter. When viewing data against X<br />
axis distance this function automatically interpolates the 1m resolution to avoid visual distortion of data. It is<br />
recommended to leave this function ON.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 17/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.3 Initial setup / Miscellaneous / special channels<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 18/133<br />
These special channels are used by Data View to create the circuit (test track) shape. Remember that the shape<br />
created will be based on the driving line taken, and may not identically represent the circuit layout.<br />
Choose the channel, which contains your vehicle speed in Kmh<br />
Choose the channel, which contains your vehicle lateral G<br />
Choose the channel, which contains your vehicle longitudinal G<br />
Offsets – For data which has not been correctly calibrated it is possible to apply offsets both positive and negative<br />
to trim the circuit shape computation. For most situations it is preferable to leave at 0<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.4 Initial setup / Miscellaneous / circuit computation<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
The options given here are purely for adjustment of the way the circuit is displayed.<br />
Auto correction ON<br />
Circuit rotation with 90deg movements<br />
DATAVIEW Pg. 19/133<br />
Activate if your circuit shape is a mirror image of the true circuit.<br />
When active this will join together both ends of the circuit shape<br />
regardless of the calculated final position.<br />
It is also presumed that the start and end of lap will join together in a<br />
straight line.<br />
Auto correction OFF<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.5 Initial setup / User configuration<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
The User function allows a number of different operators to use the same PC without<br />
modifying or affecting the functions defined by other users. To create a new user<br />
select Setup / User / Create to display this window. Give a name then press OK.<br />
Each new user will be given a unique sub folder c:\dataview\setup\NEWUSER<br />
Each user will be given unique control over the following configurations:<br />
Graph<br />
Histogram<br />
XY<br />
XYZ<br />
Lap report<br />
Parameters<br />
Circuit marker<br />
Numeric table<br />
Screen layouts<br />
Configuration bar<br />
The following configurations are global to all users<br />
General setup<br />
Virtual channels<br />
Miscellaneous<br />
Mapping parameters<br />
Session setup<br />
Car data setup<br />
Alarms<br />
Lap definition<br />
KUS<br />
T1 search<br />
Directory storage locations<br />
DATAVIEW Pg. 20/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
2.6 Initial setup / Message history<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 21/133<br />
The message history requires no configuration from the user, it is simly a visual record of activities and any warning<br />
messages that have occurred during recent activity. In the event of any system problems you may be requested to<br />
send a TXT file showing the message history to the system supplier.<br />
To access the history, select View / message history to open this window.<br />
Create a text file<br />
Clear all messages<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3. Capture configuration – Overview<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 22/133<br />
Data view offers a vast range of options to manage the way data is captured from the logger, as well as data storage<br />
and data management. The following sections will cover every configuration option. The actual download process<br />
will be covered in section 4.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.1 Capture / Setup acquisition<br />
Select Capture / Setup acquisitions to display this window.<br />
T lap loop only becomes<br />
highlighted when the Auto<br />
<strong>Download</strong> is switched off. This<br />
function automates the process<br />
of displaying the manual<br />
selection lap list.<br />
When active the list of laps in<br />
memory will be displayed as<br />
soon as the connection is<br />
recognised.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 23/133<br />
When active, the download process will begin immediately that the<br />
presence of a device with new data is recognised. For more information<br />
about manual & automatic downloads refer to section 4.3<br />
Select a source for the data.<br />
Local disk = internal flash memory of the data logger<br />
Flash card = PCMCIA memory card for use with Cobra only.<br />
Auto re-start – Following a sucessful download the logger will wait for 2<br />
minutes or until the cable is disconnected before resuming the logging.<br />
If Auto restart is active the logging process will begin immediately the<br />
acquisition trigger becomes valid following the download. For more<br />
information refer to the Table manager manual.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.2 Capture / acquisition files / options / manual<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / options tab to display the following window.<br />
DATAVIEW Pg. 24/133<br />
The entire capture system is based around the possibility of connecting to 4 different vehicles, each vehicle having a<br />
known driver. These are referred to as Car_1 to Car_4. This is the default setting for Data View<br />
Choose - Manual<br />
Cannot be edited in manual mode<br />
Cannot be edited in manual mode<br />
Used for ‘off ground’ testing of the car,<br />
accumulated distance not recognised.<br />
It is recommended to leave at 0<br />
Run recognition - Whenever a new Run is incremented the download process will create a completely new and<br />
separate data file. If switched off, all data downloads from that logger will be included within the same file.<br />
Car recognition – When switched off, the Alias and identification of the logger is not considered.<br />
Note:<br />
• In this manual mode the user is given full control over data file naming, file locations and device connection.<br />
• Device recognition is not featured in this manual mode.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.3 Capture / acquisition files / Options / Run System<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / options tab to display the following window.<br />
DATAVIEW Pg. 25/133<br />
The entire capture system is used to automatically manage the data storage, file naming and tagged data. A file tree<br />
structure will be created for you as shown at the bottom of this page.<br />
Run recognition - Whenever a new Run is incremented the download process will create a completely new and<br />
separate data file. If switched off, all data downloads from that logger will be included within the same file.<br />
Car recognition – When switched off, the Alias and identification of the logger is not considered.<br />
These folders are created from the<br />
‘Alias’ name of the logger<br />
Choose - Automatic<br />
Select the PC communication method you are using<br />
Select this to ensure automatic device recognition<br />
Used for ‘off ground’ testing of the car,<br />
accumulated distance not recognised.<br />
It is recommended to leave at 0<br />
This folder group is created from the default download folder as<br />
defined in section 6.4<br />
This ‘bench’ folder is created from the ‘Track’ choice in ‘Acquisition<br />
files / session’ – More information can be found in section 3.6<br />
This ‘test’ folder is created from the ‘Session’ choice in ‘Acquisition<br />
files / session’ – More information can be found in section 3.6<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.4 Capture / acquisition files / Cars<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / Car to display the following window.<br />
DATAVIEW Pg. 26/133<br />
The system has the capability to have unique settings for 4 different vehicles, known within the software as car1,<br />
car2, car3, car4. Each data logger (vehicle) is identified to Data View using the Alias that was attributed to the logger<br />
at the time the configuration table was programmed into it.<br />
This tab allows you to associate a ‘car configuration’ to a logger Alias.<br />
Enter any additional text using these fields.<br />
Use this pull down to select which Car you will be working with, if<br />
you only have one logger it is recommended to choose Car_1<br />
Press the Browse button to show a list of all<br />
loggers that have been connected recently,<br />
any loggers that are currently connected will<br />
be shown in Bold.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.5 Capture / acquisition files / Destination files<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / Destination files to display the following window.<br />
DATAVIEW Pg. 27/133<br />
Run system mode. There is nothing for the user to configure.<br />
Manual system mode. The user is able to select unique file<br />
locations & change the file name.<br />
At the time of Ethernet Activation you will be given the opportunity<br />
to make adjustments to these values.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.6 Capture / acquisition files / Session<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / Session to display the following window.<br />
DATAVIEW Pg. 28/133<br />
In Manual mode this information is only used as text identification<br />
for the session. In Run System mode the values of Track and<br />
Session are used to create folders for the data download, see<br />
section 3.3<br />
The comment and track length are simply text.<br />
NOTE: The session data is applied to all Cars<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.7 Capture / acquisition files / Offsets<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / Offsets to display the following window.<br />
DATAVIEW Pg. 29/133<br />
Note - The Offsets are Car specific.<br />
At the time of download, the channel offsets given in this table will<br />
be applied only to the device with the recognised Alias that is<br />
associated with a Car.<br />
There is no limit to the number of Offsets that can be created.<br />
The Channel name must be EXACTLY the same for the offset to<br />
be applied.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.8 Capture / acquisition files / user record<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / User Record to display the following window.<br />
DATAVIEW Pg. 30/133<br />
Note - The User records are Car specific and enable the user to<br />
create a set of text data tagged to each download. Text data sets<br />
may be saved and loaded from one Car to another.<br />
At the time of download, the User records given in this table will<br />
be applied only to the device with the recognised Alias that is<br />
associated with a Car.<br />
There is no limit to the number of records that can be created.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
3.9 Capture / acquisition files / constants<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Select Capture / acquisition files / constants to display the following window.<br />
DATAVIEW Pg. 31/133<br />
Note - The Constants are Car specific and enable the user to<br />
create a set of text data tagged to each download. Text data sets<br />
may be saved and loaded from one Car to another.<br />
At the time of download, the Constants given in this table will be<br />
applied only to the device with the recognised Alias that is<br />
associated with a Car.<br />
There is no limit to the number of constants that can be created.<br />
More information is available in section 7.9<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
4. <strong>Download</strong><br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 32/133<br />
The previous section 3 shows all of the download configuration options, this section deals with the actual act of<br />
downloading the data.<br />
The internal memory of any data logger is referred to as Local Disk, the Shark logger removable memory is referred<br />
to as Flash Card.<br />
Note: Before any download can be made, your logger must be visible within the DK-Link program.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
4.1 – Memory / Shark<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 33/133<br />
The Shark data logger has 2 totally independent memory locations which are written to simultaneously. The Local<br />
Disk (internal flash) is either 128Mb or 256Mb, depending on logger specification. The removable flash card memory<br />
may be any size as long as it is larger the Auto Lap limit which is typically 40Mb.<br />
Lap storage<br />
The data is divided within the logger as separate files; the file division is normally created when a lap beacon signal<br />
is seen. With this method the user is able to download individual laps rather than removing all of the laps stored in<br />
memory. A download of multiple laps only creates a single file on your PC.<br />
Latest data - on/off<br />
From table Manager the user is able to decide which type of memory management is used.<br />
Latest data on – When the logger memory becomes full the oldest lap file is deleted from memory as an entire block<br />
Latest data off - When the logger memory becomes full the memory storage stops, new data can only be stored if<br />
the Clear data command is used. See section 5.1<br />
Auto lap Limit<br />
This is an internally imposed maximum size for any one internal lap file, when the limit of 40Mb (typical Shark<br />
setting) is reached a new lap file is automatically created. This Auto lap Limit is needed for data security, systems<br />
which do not use a lap timing beacon may fill up the memory without ever seeing a lap beacon signal, the latest data<br />
function would then automatically remove the oldest lap file, which in this scenario would be all of the data. The<br />
40Mb Auto lap limit avoids this possible problem.<br />
Notes about Auto lap limit<br />
The internal channels Time and Space are not incremented by Auto lap limit<br />
The LAP counter is not incremented by Auto lap limit<br />
The ABS lap counter does increment at the Auto lap limit<br />
The LAPTIM message records the time from logger on to the previous Auto lap limit<br />
Auto lap limit is applied to Local disk as well as flash card memory.<br />
The size of the auto lap limit is a compromise between ensuring that the Auto lap limit does not interfere with the<br />
normal lap beacon > lap beacon events and possible data loss resulting from use without a beacon.<br />
The maximum data throughput of the Shark at 64,000 bytes per second (typical value) means that at maximum<br />
acquisition rate the 40Mb (40,000,000 bytes) / 64,000 = 10minutes (approx) between each Auto lap limit. This would<br />
never normally conflict with a race car lap.<br />
Memory storage<br />
Starting from a logger with empty flash card and empty Local disk, the data is stored to both locations<br />
simultaneously. At the point of memory being full, the earliest lap file is deleted from both the Local disk and Flash<br />
card.<br />
If a blank or partially filled memory card is inserted into a logger with stored data in Local disk memory the 2 storage<br />
locations become out of synchronisation. This is not a problem and they both then work independently of each other,<br />
this situation also occurs when a flash card of larger memory size is used.<br />
The Shark logger does not need the Flash card in order to function. If no card is inserted, the logger can be<br />
downloaded in the normal Ethernet method using the Local disk only.<br />
When using the Flash card to transfer data, the Local disk memory is mostly redundant and only used as a back up<br />
source in case of Flash card failure.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
4.2 – Memory / Cobra<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
The Cobra data logger has 1 memory location of 32Mb referred to as Local disk.<br />
DATAVIEW Pg. 34/133<br />
Lap storage<br />
The data is divided within the logger as separate files; the file division is normally created when a lap beacon signal<br />
is seen. With this method the user is able to download individual laps rather than removing all of the laps stored in<br />
memory. A download of multiple laps only creates a single file on your PC.<br />
Latest data - on/off<br />
From table Manager the user is able to decide which type of memory management is used.<br />
Latest data on – When the logger memory becomes full the oldest lap file is deleted from memory as an entire block<br />
Latest data off - When the logger memory becomes full the memory storage stops, new data can only be stored if<br />
the Clear data command is used. See section 5.1<br />
Auto lap Limit<br />
This is an internally imposed maximum size for any one internal lap file, when the limit of 3Mb (typical Cobra setting)<br />
is reached a new lap file is automatically created. This Auto lap Limit is needed for data security, systems which do<br />
not use a lap timing beacon may fill up the memory without ever seeing a lap beacon signal, the latest data function<br />
would then automatically remove the oldest lap file, which in this scenario would be all of the data. The 3Mb Auto lap<br />
limit avoids this possible problem.<br />
Notes about Auto lap limit<br />
The internal channels Time and Space are not incremented by Auto lap limit<br />
The LAP counter is not incremented by Auto lap limit<br />
The ABS lap counter does increment at the Auto lap limit<br />
The LAPTIM message records the time from logger on to the previous Auto lap limit<br />
Auto lap limit is applied to Local disk as well as flash card memory.<br />
The size of the auto lap limit is a compromise between ensuring that the Auto lap limit does not interfere with the<br />
normal lap beacon > lap beacon events and possible data loss resulting from use without a beacon.<br />
The maximum data throughput of the Shark at 40,000 bytes per second (typical value) means that at maximum<br />
acquisition rate the 3Mb (3,000,000 bytes) / 40,000 = 75 seconds (approx) between each Auto lap limit. At maximum<br />
acquisition throughput this would conflict with any normal lap of less than 1:15<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
4.3 – Manual download / Manual system (Cobra & Shark – Direct cable download)<br />
In this mode you should have the following system configurations.<br />
• Capture / Acquisition files / Options – Set to Manual System<br />
• Capture / Setup Acquisitions – Auto download switched OFF<br />
DATAVIEW Pg. 35/133<br />
Press the E button on the upper tool bar to display the following<br />
window. You are given the opportunity to make any adjustments<br />
to the data you have already entered.<br />
Press Next to continue<br />
Ensure that you have selected the correct Car from the pull down<br />
menu. The Connection shown at the bottom of this window will<br />
indicate if the correct device is available on the network<br />
Press Auto to use the default download directory and create a<br />
unique file name.<br />
File names for car_1 will end in C0, car_2 will end in C1, car_3<br />
will end in C2, car_4 will end in C3.<br />
Each new download using this file name will create a new run<br />
number that is attached to the end of the file name as _RUN0x<br />
You are completely free to type in your own file name and use an<br />
alternative data directory.<br />
Press Start to establish communication with the logger. Correct communication is shown by the bottom left of the<br />
screen stating ‘fast Ethernet download enabled and the E button on the tool bar will turn red. To view the data in the<br />
logger memory, select Capture / data logger manager / select laps, or press this button on the toolbar.<br />
Highlight the laps (data) you want to download and then press the<br />
<strong>Download</strong> button.<br />
Multiple laps can be downloaded using the CTRL or arrow keys in<br />
the normal Windows way.<br />
At the end of download your last lap of data will be automatically<br />
loaded into the data header bar at the top of the screen.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 36/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
4.4 – Manual download / Run system<br />
In this mode you should have the following system configurations.<br />
• Capture / Acquisition files / Options – Set Run System<br />
• Capture / Setup Acquisitions – Auto download switched OFF<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 37/133<br />
Press the E button on the upper tool bar to display the following window.<br />
You are given the opportunity to make any adjustments to the data you<br />
have already entered.<br />
For more information when selecting the Track & Session and the Run<br />
system, refer to section 3.3<br />
Press Next to continue<br />
This window shows all 4 of the possible pre-programmed vehicles. In this<br />
example, only CAR_2 has been configured within Capture / Acquisition<br />
Files / Cars to associate with a logger with Alias – Cobra<br />
Press Start to establish communication with the logger. Correct<br />
communication is shown by the bottom left of the screen stating ‘fast<br />
Ethernet download enabled’ and the E button on the tool bar will turn red.<br />
To view the data in the logger memory, select Capture / data logger manager / select laps, or press this button on<br />
the toolbar.<br />
Highlight the laps (data) you want to download and then press the<br />
<strong>Download</strong> button.<br />
Multiple laps can be downloaded using the CTRL or arrow keys in<br />
the normal Windows way.<br />
At the end of download your last lap of data will be automatically<br />
loaded into the data header bar at the top of the screen.<br />
Note : The data files used in the Run system have less<br />
identification information than those for the manual system<br />
simply because they are already stored in the correct folder for<br />
Track / Session / Alias<br />
Run<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Day Month<br />
Year<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 38/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 39/133<br />
4.5 – Automatic download / Manual system (Cobra & Shark – Direct cable download)<br />
In this mode you should have the following system configurations.<br />
• Capture / Acquisition files / Options – Set to Manual System<br />
• Capture / Setup Acquisitions – Auto download switched ON<br />
Press the E button on the upper tool bar to display the following<br />
window. You are given the opportunity to make any adjustments<br />
to the data you have already entered.<br />
Press Next to continue<br />
Ensure that you have selected the correct Car from the pull down<br />
menu. The Connection shown at the bottom of this window will<br />
indicate if the correct device is available on the network<br />
Press Auto to use the default download directory and create a<br />
unique file name.<br />
File names for car_1 will end in C0, car_2 will end in C1, car_3<br />
will end in C2, car_4 will end in C3.<br />
Each new download using this file name will create a new run<br />
number that is attached to the end of the file name as _RUN0x<br />
You are completely free to type in your own file name and use an<br />
alternative data directory.<br />
Press Start to establish communication with the logger & begin the download process. Correct communication is<br />
shown by the bottom left of the screen stating ‘fast Ethernet download enabled and the following window being<br />
shown.<br />
Yes – This will download any new data that has been created since the last<br />
download.<br />
No – This will open a list of available data, individual laps may be selected<br />
in the same way as the manual download.<br />
Cancel – Cancel download operation<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
4.6 – Automatic download / Run system<br />
In this mode you should have the following system configurations.<br />
• Capture / Acquisition files / Options – Set Run System<br />
• Capture / Setup Acquisitions – Auto download switched ON<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 40/133<br />
Press the E button on the upper tool bar to display the following window.<br />
You are given the opportunity to make any adjustments to the data you<br />
have already entered.<br />
For more information when selecting the Track & Session and the Run<br />
system, refer to section 3.3<br />
Press Next to continue<br />
This window shows all 4 of the possible pre-programmed vehicles. In this<br />
example, only CAR_2 has been configured within Capture / Acquisition<br />
Files / Cars to associate with a logger with Alias – Cobra<br />
Press Start to establish communication with the logger & begin the<br />
download process. Correct communication is shown by the bottom left of<br />
the screen stating ‘fast Ethernet download enabled and the following<br />
window being shown.<br />
Yes – This will download any new data that has been created since the last<br />
download.<br />
No – This will open a list of available data, individual laps may be selected<br />
in the same way as the manual download.<br />
Cancel – Cancel download operation<br />
Note : The data files used in the Run system have less<br />
identification information than those for the manual system<br />
simply because they are already stored in the correct folder for<br />
Track / Session / Alias<br />
Day Month<br />
Year<br />
Run<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 41/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
5. Connection tools<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 42/133<br />
Connecting to a data logger does not necessarily mean that you have to perform a ‘download’. The method of<br />
connection is however almost identical.<br />
From the upper menu ensure that the Auto <strong>Download</strong> button is switched off, in this way there will be no attempt by<br />
the logger to extract data. Then activate the Ethernet by pressing the E button<br />
Press here to activate Ethernet<br />
Press Next to skip this window. Because you<br />
are not planning to capture data it is not<br />
necessary to enter any information.<br />
Switch OFF the Auto download button<br />
Press Start to initiate the Ethernet link. Because you<br />
are not planning to capture data it is not necessary to<br />
enter any information, or select a Car – Example<br />
window shown is Manual Method<br />
If you have not already Run the DK-Link program you will be presented with the<br />
following notice. Press Run to activate DK-Link which will appear at the bottom of<br />
your screen as a new window.<br />
If all is configured and connected correctly DK link will show the presense of a data logger similar to the image<br />
shown below, and the bottom right of your computer screen will show the logger table name and the Alias of the<br />
device.<br />
Logger table + Alias<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
5.1 – Data logger manager / Clear Data<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 43/133<br />
The Clear data command deletes all stored data from the logger memory, as well as returning the Run counter to 1.<br />
For more information about memory management refer to sections 4.1 and 4.2<br />
Note: This process requires an active Ethernet connection & your logger must be visible within the DK-Link program.<br />
From the upper menu select Capture / Data logger / Clear data. You will be given<br />
the following confirmation box. Press OK to clear data and check the bottom left of<br />
your screen to ensure that you have received confirmation of process completion<br />
Note: You logger will now wait for the cable disconnection or the 120sec timeout before resuming any logging<br />
activity.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
5.2 – Data logger manager / Re-start<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 44/133<br />
Following a Clear data command no logging activity will begin until either the cable is disconnected or the 120sec<br />
automatic timeout is reached. This delay can be by-passed using the re-start command.<br />
Note: This process requires an active Ethernet connection & your logger must be visible within the DK-Link program.<br />
From the upper menu select Capture / Data logger / Restart. Confirmation of process<br />
completion is seen at the bottom left of the screen, as seen here.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
5.3 – Data logger manager / Show devices<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 45/133<br />
In order to check the presence of a logger on your network, select Capture / Data logger /<br />
Show devices from the upper menu. Any data loggers connected to your network will be<br />
shown in the dialog box, as seen here<br />
Note: This process requires an active Ethernet connection & your logger must be visible within the DK-Link program.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
5.4 – Data logger manager / Show Laps table<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 46/133<br />
The data logger manager also lets you view any laps or runs stored in memory. Select Capture / Data logger /<br />
Select Laps from the upper menu, An empty data logger will look like the image on the left, a logger with stored<br />
data will look like the right hand image.<br />
For more information about manual download, refer to section 4.3<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6. General Setup / Graphs<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 47/133<br />
This configuration environment gives the user a series of controls for the way in which Data View functions and<br />
displays the information.<br />
From the upper menu select Setup / General / Graphs to display this window.<br />
Show grid – Background grid on all analysis windows<br />
Auto Scale – See section 9 for all scaling options<br />
Auto Connect – Links the cursors within all analysis windows to show the same time or distance position<br />
Auto connect zoom – The same level of zoom will be applied to all analysis windows.<br />
Auto align Y scales – Ensures that the left hand edge of all tiled graph windows are vertically aligned<br />
Keep zoom after changing layout – The current zoom level is retained after the window layout is changed<br />
Keep zoom after changing lap – The current zoom level is retained after the lap data is changed<br />
Font size – Font size may be changed to suit different screen resolutions and also to maximise the usable analysis<br />
area.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6.1 – General setup / Data RX<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 48/133<br />
Auto RX updates the analysis window as each lap is downloaded. This can slow down the download process,<br />
especially if the analysis windows have complicated virtual channels.<br />
Lap definition – This is defined in section 2.1<br />
By default the Auto RX is active for both Real time data and<br />
Ethernet data sources. To adjust these options double click the<br />
Auto RX line to display this window.<br />
Switch off the data sources that are not required, by default all<br />
are switched on<br />
Auto RX remote – Similar to Auto RX but with the data source on a remote host PC.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6.2 – General setup / Colours<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 49/133<br />
The colours tab gives you control over the display area as well as the data contained within the analysis windows.<br />
Windows background – Outside border of analysis window<br />
Boxes background – inside area of analysis window<br />
Add – create customised colour schemes<br />
Comparison – Whenever a comparison of more than one data set is<br />
selected, the data will be represented using the colours defined in this<br />
comparison table.<br />
In this example the first data set selected will be shown as yellow, the<br />
second selection as red, etc.<br />
Your colours should be chosen to give the clearest representation against your selected Boxes background. You do<br />
not need to worry about light colours not printing as colour swap is available in the print menu, section 25.<br />
Experience has shown that all backgrounds black, with very light colours for your comparison work the best, with<br />
yellow best of all.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6.3 – General setup / Search<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 50/133<br />
This tab gives the user a number of controls to pinpoint an event that occurs within the viewed data set.<br />
Alarms – This configuration and other related options are provided in more detail within section 10<br />
Event T1 - This configuration and other related options are provided in more detail within section 24<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6.4 – General setup / Directories<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
This tab allows the user to define all of the default file locations for using Data<br />
View. From the pull down menu,<br />
each of the following locations may<br />
be defined.<br />
DATAVIEW Pg. 51/133<br />
Data directory – This is the short-cut folder list used by the data<br />
browser when choosing a data file to open. Up to 20 different short<br />
cuts may be defined.<br />
<strong>Download</strong> directory – This is the default root folder used by the<br />
download process to store captured data. Only one folder may be<br />
defined<br />
Export directory – Location for any data that is exported out of Data<br />
View. Only one folder may be defined<br />
Browser start-up directory – Default folder that is shown whenever<br />
the data browser is opened. Check box must be active to use this<br />
function. Only one folder may be defined<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
6.5 – General setup / Miscellaneous<br />
This tab allows the user to define all non related settings<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 52/133<br />
Selects methods for applying the offset and Gain to channels. Offset<br />
& Gain may be global as defined in the parameters (section 9.2), or<br />
Run specific if Car recognition is activated as part of the download<br />
process.<br />
From the offset & gain mode the following<br />
selections are available<br />
OFF – All parameters and Gains are not<br />
applied regardless of source origin.<br />
File table – Offsets & Gains are taken only from the settings unique<br />
to the Car in Setup Acquisition.<br />
Parameter settings - Offsets & Gains are taken only from the parameters as detailed in section 9.2<br />
Table + parameters (default setting) – Combines Run & Parameter values.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7. Data file management<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 53/133<br />
Every aspect of data file management is done via the Data Browser. This can be opened by pressing this button on<br />
the top tool bar or by pressing F3<br />
Data browser<br />
Your typical data browser will look like this<br />
Pull down list of shortcut folders<br />
Data files shown in this section<br />
Data file structure for Run System<br />
Day Month<br />
Data file structure for Manual System<br />
Day/month/year<br />
Hour / Min<br />
Year<br />
Run<br />
Car No. Run count<br />
Car 1 ----------------------------- suffix C0<br />
Car 2 ----------------------------- suffix C1<br />
Car 3 ----------------------------- suffix C2<br />
Car 4 ----------------------------- suffix C3<br />
Laps within each data file are shown here<br />
Data file naming is done<br />
automatically during the<br />
download following the<br />
sequence shown below.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.1 – Data browser / Delete laps<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 54/133<br />
Click each lap that you want to delete in the right hand window, then press the Delete key on your keyboard. To<br />
select more than one lap, hold down the Ctrl key when selecting with the mouse click.<br />
If all laps are deleted within a<br />
Run then the Run is also<br />
deleted. It may take 2-3 seconds<br />
to refresh the Run listing, or<br />
press F5 to refresh the screen.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.2 – Data browser / Restore laps<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 55/133<br />
When any lap is deleted the original file is retained with the suffix changed from *.DTX to *.OLD.<br />
Any original file may be restored using Windows Explorer to locate the file and Renaming it back to a *.DTX file.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.3 – Data browser / Edit properties / Header<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 56/133<br />
The header menu gives the following information that may be<br />
edited.<br />
Abs – Absolute lap count number<br />
Run – Session counter<br />
Lap – Lap count from the beginning of the Run<br />
Lap Time – lap time in mins / sec / hundreds<br />
Lap distance – measured lap distance<br />
NOTE – Changing the lap distance does not affect the data in any<br />
way, this is simply a text notation.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.4 – Data browser / Edit properties / Comment<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 57/133<br />
The Marker box is used to identify the type<br />
of lap.<br />
Lap – Normal lap which begins and ends<br />
with a signal from the lap beacon<br />
Out – First lap in a Run<br />
Box – Last lap in a run<br />
Test – Test lap with car stationary, wheels<br />
rotating<br />
Engine test – Engine run only<br />
Out + Box – Out lap followed by return to pits<br />
Best lap – Fastest lap in Run<br />
Trigger out – Telemetry data only<br />
Comment – This is purely a text value, which may be assigned by the user to help identify an event within the data.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.5 – Data browser / Edit properties / Session<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 58/133<br />
In Manual system mode, all of the Session options are text only<br />
and are intended as guide to assist with data identification. In<br />
Run System mode these entries control the folder structure. See<br />
section 3.6<br />
Track length – text only with default value of 0, this may be used<br />
to input the known track length<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.6 – Data browser / Edit properties / car<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 59/133<br />
All of the Car options are text only and are intended as guide to<br />
assist with data identification.<br />
Track length – text only with default value of 0, this may be used<br />
to input the known track length<br />
These values are allocated to the file during the data download.<br />
Box – Pit garage number<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.7 – Data browser / Edit properties / Constants<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
Example of the use of a file constant:<br />
DATAVIEW Pg. 60/133<br />
During the download process Constants may be created and<br />
attached to any data file that is captured from a specified data<br />
logger.<br />
Constants may be used within Virtual channels to make your<br />
mathematical output specific to the data from each logger.<br />
Within this Constants menu it is possible to view any Constants<br />
that have been allocated during download, add any new ones as<br />
you want, or edit the values of any.<br />
Constants may be saved or loaded into other data file sets using<br />
the Load and Save As functions<br />
For more information see section 3.9<br />
To work out the mathematical spring load based on spring movement the mathematics would be a simple mm of<br />
movement x spring rate. Where the mm of movement is measured using the logger as a variable value and the<br />
spring rate is a fixed constant.<br />
Now consider a comparison of two peaces of data where the spring rate is different for each. The mathematics must<br />
now be mm of movement from data file 1 x spring rate 1 compared to mm of movement from data file 2 x<br />
spring rate 2.<br />
The spring rate is defined using the data file constants so that the mathematical comparison remains accurate.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.8 – Data browser / Edit properties / Offsets<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 61/133<br />
The Offsets tab gives details of the Offset and Gain that has been<br />
applied to all channels during the download process. Typically 0<br />
and 1<br />
This Offsets tab gives you the opportunity to make changes to the<br />
data relating to that data file (or individual lap) only.<br />
For more information see section 3.7<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.9 – Data browser / Edit properties / Record<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
From your data browser window,<br />
highlight any lap or group of laps<br />
that you wish to view / edit the properties of then press this button on the tool bar.<br />
DATAVIEW Pg. 62/133<br />
The Record tab gives details of text constants that have been<br />
applied to all channels during the download process.<br />
Text constants may be used to create a database of facts relating<br />
to a specific data logger installation.<br />
For more information see section 3.8<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.10 – Data browser / Channel info<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 63/133<br />
Channel info allows you to modify the name of individual channels and the number of decimal places. From your<br />
data browser window highlight the file you wish to work with, then select Edit / Edit channel info from the upper menu<br />
to open the following window.<br />
All of your channel names are given on the left side. All values<br />
may be edited as well as adding a text notation to each.<br />
This function is of vital importance when trying to compare data<br />
files with similar data but different channel names.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.11 – Data browser / Search laps<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 64/133<br />
Under most conditions this function is not required as it is performed automatically during the download, providing<br />
that the configurations have been set as shown in section 2.1. For data which has been downloaded into a computer<br />
that has not been configured correctly the user can choose to make the necessary configuration changes and then<br />
re-define the laps within the data browser under the tools menu Tools / Define laps / Search laps<br />
For data which has not been defined into laps via the lap input beacon it is possible to manually split a large piece of<br />
data in smaller sections (laps).<br />
The first step is to define the positions within your data for the split<br />
points. Open your single lap of data using the data browser and<br />
visualise this within a graph window.<br />
From the upper menu, select Utility / Define Laps / Manual definition.<br />
Your cursor will now change to 2 vertical bars. Use your mouse left<br />
button to click the positions on the graph for the positions of the lap<br />
beacon, make as many as you need.<br />
Your graph will now show a series of vertical bars as shown here.<br />
Note: These marks may be placed manually using the<br />
keyboard Insert command<br />
Press the END key to split the data into laps.<br />
If you make a mistake, refer to section 7.13 for the facility<br />
to restore to a single lap.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.12 – Data browser / Layout<br />
From the upper menu of the data browser, select<br />
View / Options to display the window below.<br />
This Options window dictates the layout and<br />
amount of information shown in the data<br />
browser.<br />
The upper window shows the information that will be shown in<br />
the left pane of the data Browser window. The lower window<br />
controls the right.<br />
Press the Add button to display a list of all options that are<br />
available.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 65/133<br />
Filename ...................Adds file name alongside each lap / right<br />
Filename (session) ...Adds file name adjacent to each Run / left<br />
Abs............................Absolute lap count starting from the beginning of the session / right<br />
Run ...........................Run counter<br />
Lap............................Lap count starting from ‘out lap’<br />
Lap time ....................Count in min/sec/hund for each lap<br />
Lap distance .............Distance stated in data header (not measured)<br />
Lap marker................Type of lap<br />
Lap comment ............Additional text data tagged to lap<br />
Lap time (marker) .....same as lap time<br />
Lap date....................Date of lap<br />
Lap hour (start) .........start time of data<br />
Lap hour (end) ..........end time of data<br />
Lap size.....................size in bytes<br />
Track name...............name of track<br />
Track length ..............stated lap length<br />
Session name ...........name defined during session setup<br />
Session comment .....comment defined during download<br />
Session date .............date of download taken from PC<br />
Session hour.............time of download taken from PC<br />
Driver name ..............name of driver<br />
Car name ..................Alias<br />
Box number...............Pit garage<br />
Driver comment ........comment tagged to each driver at download<br />
Engine name.............comment tagged to each Car at download<br />
Fuel consumption .....fuel data<br />
Fuel level...................level at end of lap<br />
Logging table name ..setup table from table manager<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 66/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.13 – Data browser / Export / DTX<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 67/133<br />
The export as DTX enables a group of laps within a Run to be re-assembled into one single lap, or simply as a renaming<br />
tool.<br />
Choose a file name and a folder to store the export file, the Save<br />
First, highlight all of the laps that you wish to re-assembly, then<br />
from the Tools menu, select Export / DTX…. To display the<br />
window on the left.<br />
Press Yes to open this window:<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.14 – Data browser / Export / DTX Channels<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 68/133<br />
The export as DTX channels enables a new data file to be created with either a reduced list of channels and if<br />
required only a small sub-section of the total data.<br />
This function requires the interaction of the Numeric Table window which is shown in detail within section 19<br />
Within the Data Browser window, highlight the laps which contain the data you wish to export, then select Tools /<br />
Export / Channels to DTX. This will open the search window for the NTB files as shown here.<br />
NTB files are created whenever a new Numeric Table is created. A new<br />
empty installation may be opened using the default.ntb file, which will<br />
appear as follows.<br />
Use the Add button to include any<br />
channels that you want to be added to<br />
your new data file. Press OK to begin<br />
the export.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.15 – Data browser / Export / Ascii<br />
The export as Ascii enables data to be created in Ascii format.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 69/133<br />
This function requires the interaction of the Numeric Table window which is shown in detail within section 19<br />
Within the Data Browser window, highlight the laps which contain the data<br />
you wish to export, then select Tools / Export / Ascii. This will open the<br />
search window for the NTB files as shown here.<br />
NTB files are created whenever a<br />
new Numeric Table is created. A<br />
new empty installation may be<br />
opened using the default.ntb file,<br />
which will appear as follows.<br />
Note: The resulting *.PRN file may be opened using Excel<br />
Use the Add button to include any channels that you want to be added to your<br />
new data file.<br />
Use the Freq window to determine how often the channel data will be updated<br />
within the Ascii file<br />
All Data – Tick this box to export all data within your lap selection, when unticked,<br />
use the Time 1 / Time 2 to define the area of data to export<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.16 – Data browser / Export / Binary<br />
The export as Binary enables data to be created in Binary format.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 70/133<br />
This function requires the interaction of the Numeric Table window which is shown in detail within section 19<br />
Within the Data Browser window, highlight the laps which contain the data<br />
you wish to export, then select Tools / Export / Binary. This will open the<br />
search window for the NTB files as shown here.<br />
NTB files are created whenever a<br />
new Numeric Table is created. A<br />
new empty installation may be<br />
opened using the default.ntb file,<br />
which will appear as follows.<br />
Use the Add button to include any channels that you want to be added to your<br />
new data file.<br />
Use the Freq window to determine how often the channel data will be updated<br />
within the Binary file<br />
All Data – Tick this box to export all data within your lap selection, when unticked,<br />
use the Time 1 / Time 2 to define the area of data to export<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.17 – Channel browser / Display<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
The channel browser can be toggled on/off using the F2 key and removed by pressing<br />
the X at the top left or by pressing Esc on the keyboard. The channel browser will<br />
show all channels that are available in the current loaded data file + mathematical<br />
channels (virtual) + real time radio channels.<br />
Within this simple list there are a number of subtle bits of information.<br />
• All channels that are taken from the logger as real measured channels are<br />
yellow<br />
• All white channels are mathematical (virtual) creations formed within Data<br />
View<br />
• Channels with this marking have been given a fixed scaling<br />
parameter, see section 9.3<br />
• Channels with a dot at the bottom right have a filter applied<br />
within their parameters, see section 9.4<br />
• Channels with a red dot at the upper left have been<br />
allocated an alarm range, see section 10.0 / 10.1<br />
DATAVIEW Pg. 71/133<br />
To add any channel from the channels Browser to any analysis window, simply drag ‘n’ drop. Normal Windows<br />
functions of using the Ctrl or arrow keys to make multiple selections may be used.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
7.18 – Channel browser / Options<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 72/133<br />
The channel browser may be modified by clicking anywhere in the window with the right mouse button and selecting<br />
Setup to display this window.<br />
Use the check boxes to turn off/on the type of channel you want to see.<br />
UDA channels – Any channels that are sourced by cable / memory card download<br />
directly from the data logger.<br />
Virtual channels – Any mathematical channel<br />
Realtime channels – Any channels received via radio link. It is normal when using<br />
radio telemetry to have multiple channels of the same name. Example – RPM channel captured via normal cable<br />
method may be higher frequency than the same RPM channel that has been captured via radio link, you choose<br />
which one you want to analyse.<br />
Dock list – When active the channel browser will lock itself to the left hand edge of the screen, when – un-docked<br />
the window will be free floating.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
8. Open Data - Overview<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 73/133<br />
Using the Data Browser (F3) you are able to choose the data you want to open in a number of ways.<br />
8.1 – Data selection<br />
Single lap – Highlight any single lap in the LAP pane, then press the ‘Open’ button, or simply double click with the<br />
left mouse button.<br />
Consecutive multiple laps – Click and hold down the left mouse button as you drag down to select all of the laps<br />
you want, and then press the ‘open button’<br />
Multiple non-consecutive laps – Hold the Ctrl key down then select each one you want with the left mouse key,<br />
and then press the ‘open’ button.<br />
Folder search<br />
RUN Pane<br />
Open the<br />
selection<br />
Clear the<br />
comparison<br />
Add to<br />
comparison<br />
Select<br />
fastest lap<br />
LAP Pane<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
8.2 – Data selection / Comparison<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 74/133<br />
Highlight any lap or group of laps that will form your first choice for comparison, then press the ‘Add to comparison’<br />
button. Then highlight your second choice and press the same button again. Your selections will be shown at the<br />
bottom of the Data Browser window as shown here on the right.<br />
Now press the ‘open’ button to load your selections.<br />
You are able to select up to 6 sets of comparison<br />
data simultaneously. The colour of each will be<br />
automatically allocated as per your choices in<br />
General Setup – section 6.2<br />
Remember to read section 2.2 with reference to<br />
distance alignment on comparison.<br />
Open the<br />
selection<br />
Add to<br />
comparison<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9. Scaling<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 75/133<br />
Data view has a great many options for scaling the data with 2 levels of manual scaling as well as fully automatic.<br />
Depending on the settings chosen, the following rules can be used to determine which set of scaling data is being<br />
applied to a channel.<br />
Local manual scale – section 9.6 - When applied to the channel within the analysis window. Regardless of any<br />
other settings, this will always be used and will take priority over other settings<br />
Auto scale / General setup – section 9.1 – Providing there are no local scales automatic scaling will be applied to<br />
all channels based on their max / min values within the analysis window.<br />
Channel parameter – section 9.2 – Providing there is no local scaling and auto scale is switched off, the channel<br />
will be scaled using the range defined in Parameters. If there is no parameter set, no local scale and Auto scale is<br />
turned off, Auto scale will be applied.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9.1 – Scaling / Automatic<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 76/133<br />
Providing there are no local scales automatic scaling will be applied to all channels based on their max / min values<br />
within the analysis window. To switch this on/off, select Setup / general / Graphs from the upper menu to display this<br />
window.<br />
Switch here.<br />
You will also notice that the lower right of<br />
your screen shows the status of the Auto<br />
scale option<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9.2 – Scaling / Parameters<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 77/133<br />
Providing there is no local scaling and auto scale is switched off, the channel will be scaled using the range defined<br />
in Parameters. If there is no parameter set, no local scale and Auto scale is turned off, Auto scale will be applied.<br />
The easiest way to create a channel parameter is to open the Channel<br />
Browser (F2) then right click the channel you want to set a parameter for<br />
as shown here. Select Add to Parameters to display the following<br />
window.<br />
Any text given here will be<br />
displayed whenever this<br />
channel is chosen<br />
Fix the Min / Max range in<br />
normal engineering units<br />
Apply any offset or Gain as<br />
necessary<br />
When complete your channel<br />
will be give a scale icon<br />
alongside the name<br />
Parameters may be edited at any time via the Channel browser of by selecting Configure / parameters from the<br />
upper menu. They may also be accessed directly from the analysis window by ‘right clicking’ the coloured bar<br />
alongside the channel name.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9.3 – Scaling / Parameters / Run average<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 78/133<br />
Providing there is a parameter created for a channel (section 9.2), you are able to apply a Run Average filter. These<br />
filters are time based and will create a smoother set of data which gets smoother the longer the time base.<br />
There are however some important things to remember.<br />
• Any mathematical channels that use a filtered channel in their calculation will be affected by the amount of<br />
filtering. Example – A damper position sensor gives a very fast moving trace, which can be better seen<br />
using a high filter to create an average value, any damper rate of change mathematics would give a very<br />
poor reading based on filtered raw data.<br />
• There is little point in sampling very fast if it is your intention to smooth everything out.<br />
Choose Run Average then choose a<br />
Length from the pull down menu<br />
Example of Run Average filters applied to the same data<br />
No filter applied<br />
Same data with a 1.000 filter applied<br />
Fast access to any channel Parameter<br />
can be done by a ‘right mouse click’ on<br />
data view_std_manual this vertical v1.4.doc coloured band.<br />
Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9.4 – Scaling / Parameters / FFT<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 79/133<br />
Providing there is a parameter created for a channel (section 9.2), you are able to apply an FFT filter. These filters<br />
are frequency based and are used to include / exclude certain frequency ranges from your data.<br />
Within your channel parameter window, select FFT from the Filter pull down menu.<br />
Define up to 3 filters from the following types and enter your chosen frequency range.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
9.5 – Scaling / Local scaling<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 80/133<br />
Within all types of analysis window a fixed scale may be applied to a channel. These local analysis scales take<br />
priority over every other scale setting.<br />
A local channel scale window will appear as follows:<br />
This window is opened by a ‘right mouse click’ of the coloured band alongside each channel and selecting<br />
Properties.<br />
This window also permits a number of other options not related to the scaling.<br />
Auto Compare – Shows both sets of data of comparison, or the difference between the comparison data.<br />
Colour – Channel colour – Note, this colour is only used when there is no multiple data comparison.<br />
Style – Choose your line style & thickness<br />
Box – See section 11.15<br />
Select – Manual scale<br />
Choose the max / min<br />
channel value<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
10. Alarms<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 81/133<br />
Any channel you configure within Alarms is continuously monitored within the data set you are viewing.<br />
To activate the alarms system, select Setup / General / Search from the upper menu to display the following window.<br />
Use the pull down box to choose from one of the following<br />
OFF – No Alarm search<br />
Show Alarms – Automatically show any Alarm that exceeds<br />
your limits.<br />
Show All – Permanently show all Alarms regardless of state.<br />
To create an Alarm, select Configure / Alarms from the upper menu to display this wiondow.<br />
Press Add to create an Alarm as shown here.<br />
Double click the entry to open the configuration window.<br />
The OK range is considered as the normal working range of the channel<br />
The valid range is the maximum working range of the sensor, outside of this is<br />
considered a sensor fault and an Alarm is not indicated<br />
For information about Conditional channels, see section 24.2<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
10.1 – Alarm / Window<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 82/133<br />
The Alarms window is free floating on top of other windows and will appear / disappear depending on the values of<br />
data seen. In this first example a single channel has been found with a high oil pressure indicated as red. This<br />
search was defined as Show Alarms<br />
This example shows both a valid and non-valid alarm, the configuration is set to Show All<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
11. Graph window / Overview<br />
Notes relating to the Graph window.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
• Any number of individual graph windows may be created and stored<br />
• A maximum of 39 channels may be viewed in any one graph window.<br />
• Graphs may be viewed with Time or Distance on the X axis<br />
• Multiple graphs may be viewed simultaneously<br />
• All graph windows end in .gra and are stored in c:\Data view\setup<br />
Navigation using the keyboard.<br />
DATAVIEW Pg. 83/133<br />
Use the Up / Down key to change the X<br />
axis step value<br />
Use the Left / Right key to move the<br />
cursor left / right by the step value<br />
above<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 84/133<br />
11.1 – Graph / New – Load - Swap<br />
To create a new graph window, select Graph / Graph window / Open from the upper menu, or press this button on<br />
the tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty graph window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
The default setting is always Time for the X axis.<br />
Tip – Any highlighted graph window may be swapped for any other graph window using the CTRL-D keyboard<br />
shortcut. The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
11.2 – Graph / Window layout<br />
Time at current cursor<br />
position<br />
Max scale<br />
being applied<br />
Channel<br />
name<br />
Min scale<br />
being applied<br />
Time or<br />
Distance<br />
scale<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
Percentage of current lap<br />
currently being viewed<br />
DATAVIEW Pg. 85/133<br />
Left to right position indicates the approximate<br />
position within the current total data<br />
Step value for<br />
keyboard<br />
Channel value<br />
at current<br />
cursor<br />
position **<br />
** A star alongside a channel value indicates that the value is taken from an actual measured point rather than an<br />
interpolated value.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 86/133<br />
11.3 – Graph / Add – Remove channel<br />
The lower toolbar changes automatically to suit the type of window you have highlighted. If a graph window is<br />
selected you will see the following toolbar at the bottom of the screen. Click any area within the central graph<br />
window then press the button shown here to enter the graph window properties.<br />
Use the Add button to open the Channel Browser and either<br />
‘double click’ or ‘drag n drop’ channels into the main window.<br />
Press OK to Save & exit<br />
This window can also be used to<br />
remove any channel<br />
An alternative method is to make channel changes directly within the graph window.<br />
IMPORTANT - Any changes made using the following methods will not be saved until you try to close or swap the<br />
graph window.<br />
Use the right mouse button to click the coloured band next to any channel, then<br />
select Remove to remove a channel.<br />
To add a channel, simply press F2 to open the Channel Browser and ‘drag n drop’ any channel directly into the<br />
graph window.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 87/133<br />
11.4 – Graph / Properties<br />
The lower toolbar changes automatically to suit the type of window you have highlighted. If a graph window is<br />
selected you will see the following toolbar at the bottom of the screen. Click any area within the central graph<br />
window then press the button shown here to enter the graph window properties.<br />
Graph<br />
displayed<br />
against Time<br />
or Distance<br />
Display style<br />
Parallel<br />
Overlay<br />
Manual<br />
See below<br />
Double click any channel to<br />
view the individual channel<br />
properties, as detailed in<br />
section 11.5<br />
Move the channel up / Down<br />
within the graph window<br />
Graphs viewed in Parallel mode<br />
Graphs viewed in Overlay mode<br />
Load an alternative graph<br />
configuration.<br />
Save the current configuration<br />
as an alternative name.<br />
Clear all loaded channels<br />
Remove the single highlighted<br />
channel<br />
Opens the channel browser to<br />
load another channel<br />
Graphs viewed in Manual mode where each graph is given a fixed<br />
percentage of the vertical space within the graph window to use.<br />
To apply the Manual percentage see section 11.5<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 88/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 89/133<br />
11.5 – Graph / Properties - Channel<br />
Right mouse click the coloured band alongside any channel name to display the channel properties within the<br />
current graph window. Or double click any channel within the graph properties window as shown in section 11.4<br />
Right mouse click any of<br />
these coloured bands<br />
Step – Graph continues horizontally until a revised value is seen at the next acquisition<br />
point. (Default value)<br />
Line – Direct join of each acquisition point<br />
Dot – Single point representation of each acquisition point<br />
Marker – Cross placed at each acquisition point<br />
Channel name<br />
Comparison type<br />
Line style & thickness<br />
Scaling<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 90/133<br />
11.6 – Graph / Time or Distance<br />
All data is captured using a time reference (Hz) therefore the standard method of analysis uses Time as the X axis<br />
for any graph window. There are however occasions when the Distance axis is more suitable, such as comparisons<br />
over a fixed distance (Lap against L.ap)<br />
The problem of comparing two sets of data against Time are shown on the graph comparison below. Each set of<br />
data covers the same section of track<br />
and start at the same physical point,<br />
the gradual misalignment of data is a<br />
function of the difference in time each<br />
vehicle takes to cover the same<br />
distance, as shown here<br />
Data misalignment<br />
This same piece of data when viewed using Distance completely removes the misalignment because the data is<br />
referenced to a physical position on<br />
the track rather than a time.<br />
Presuming that both pieces of data<br />
cover the same distance there will be<br />
no misalignment. To understand this<br />
process more thoroughly, read section<br />
2.2.<br />
To change between Time & Distance, either open the graph properties window and make the change as detailed in<br />
section 11.4, or press this button on the lower tool bar<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 91/133<br />
11.7 – Graph / X axis Shift<br />
Each set of data begins starts from one of the following functions: Power on / Trigger active / lap beacon. When<br />
comparing 2 or more sets of data, the event you wish to compare may occur at a different Time from the beginning<br />
of the data set, for this reason it is necessary to shift either an individual channel or and entire set of data either left<br />
or right to make it align with other data channels.<br />
The following piece of data shows a damper measurement over a fixed bump in the track, the blue and red channels<br />
are from different vehicles and have hit the bump at a<br />
different time within the data set. This is shown my the<br />
misalignment of the comparison.<br />
Shift a graph .............. Shift only a single graph<br />
Shift a comparison ..... Shift every channel from the selected data set<br />
Shift a lap................... Shift every channel within the selected lap<br />
Reset graphs ............. Remove the graph shift<br />
Use the Shift command from the lower tool<br />
bar and choose from one of the following<br />
options.<br />
After any of the upper 3 are used and the appropriate data selected your mouse will turn into a hand, physically drag<br />
the data until you are happy with the alignment and then release the mouse button and press Enter on your<br />
keyboard<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
11.8 – Graph / Info<br />
Press the following button on the lower tool bar.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 92/133<br />
The following window will show information relating only to the visible area, any data outside of the current zoom is<br />
not considered.<br />
Name ......................... Channel name<br />
Colour ........................ Graph colour being used<br />
Min Box...................... Minimum value within the viewed area**<br />
Max Box..................... Maximum value within the viewed area**<br />
Offset ......................... Any Offset that has been applied with the Paramaters section – see section 9.2<br />
Gain ........................... Any Gain that has been applied with the Paramaters section – see section 9.2<br />
Shift............................ The amount of X axis shift – see section 11.7<br />
** If a channel is filtered in any way, the filtered min / max values will be shown.<br />
Area of data being considered, if Distance is being<br />
used as the X axis, this will show meters instead of<br />
Time<br />
Channel data<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
11.9 – Graph / Max / Min<br />
Press the following button on the lower tool bar.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 93/133<br />
The following window will show Max / Min information relating only to the visible area, any data outside of the current<br />
zoom is not considered.<br />
Name ......................... Channel name<br />
Min ............................. Minimum value within the viewed area**<br />
Min X.......................... value in Time or Distance where the Min value occurred<br />
Max ............................ Maximum value within the viewed area**<br />
Max X......................... value in Time or Distance where the Max value occurred<br />
Avg............................. Average channel value<br />
Avg (Abs) ................... Average channel value (based on Absolute channel values)<br />
S Dev ......................... Standard deviation channel value<br />
Res............................. Decimal places resolution of channel<br />
** If a channel is filtered in any way, the filtered min / max values will be shown.<br />
Area of data being considered, if Distance is being<br />
used as the X axis, this will show meters instead of<br />
Time<br />
Channel data<br />
Tip – The Max / Min window can be activated by pressing and holding your right mouse button and dragging it to<br />
form a zone between 2 grey vertical lines, when you release<br />
the mouse button you will be asked to choose from Zoom or<br />
Max / Min as shown here. Choose Max / Min, your data will<br />
relate only to the area between the 2 grey boundary lines.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 94/133<br />
11.10 – Graph / Cursor<br />
The Cursor function allows a reference point to be placed on the graphical data. Two options are available.<br />
To activate either of the Cursor functions, first click the coloured band as shown here with<br />
your right mouse button to display this list of options.<br />
Single graph cursor. – This gives a ‘cross hairs’ tracking cursor on a single channel giving the information shown<br />
below.<br />
Cursor point<br />
Min..............................Minimum value within the viewed area**<br />
Max.............................Maximum value within the viewed area**<br />
Avg .............................Average channel value<br />
All graph cursor. – First place your cursor at the position where you want the reference point to be, then press the<br />
All Graphs Cursor option to display the following window.<br />
Moving cursor<br />
position<br />
Cursor Datum<br />
Right mouse click any of<br />
these coloured bands<br />
Preceding 2 acquisition points<br />
Value at cursor position<br />
Following 2 acquisition points<br />
Datum ........................ Time or Distance position of the Cursor datum.<br />
X................................. Current cursor position in Time or Distance<br />
Delta X ....................... Difference in Time or Distance from the current<br />
cursor position to the Datum position.<br />
Channel values<br />
Val = Current<br />
Datum = Value at datum<br />
Difference = Difference from current to Datum<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 95/133<br />
11.11 – Graph / Search<br />
The search function allows you to search and automatically move your cursor to the Min or Max value of any<br />
channel.<br />
To activate the search, first click the coloured band as shown here with your right mouse<br />
button to display this list of options. Select either Minimum or Maximum<br />
Right mouse click the band<br />
alongside the channel you<br />
wish to search<br />
** If a channel is filtered in any way, the filtered min / max values will be shown.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
11.12 – Graph / Zoom<br />
Zoom can be manipulated in any of the following ways.<br />
Zoom in by 50% focused around the current cursor position<br />
Zoom out by 50% focused around the current cursor position<br />
Zoom to the current cursor position + / - 1 sample data point<br />
Zoom out to full graph (max screen)<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 96/133<br />
Changes your cursor to a magnifying glass, click the graph screen once to mark the left hand edge of the zoom<br />
area, click a second time to mark the right hand edge of your zoom area.<br />
Drag to move your zoom area<br />
The top of your graph screen shows a block as an indication of your current zoom ammount and the approximate<br />
position within the full data set of your current zoon, this blue area may be dragged, left or right to move your graphs.<br />
Tip – If your mouse has a roller wheel, try this when you are zoomed in. The speed of scroll is dictated by the Step<br />
value in the upper right of your graph window, see section 11.2<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 97/133<br />
11.13 – Graph / Snap<br />
All data is taken with reference to a Time base in Hz. Each channel graph is made up of actual measuring points<br />
and interpolated points. To be sure that the data you are seeing is a real measured point select the Snap option<br />
from the lower menu, and choose the frequency range that matches your chosen channel.<br />
You will see that the cursor will only rest on an actual measuring point.<br />
Measuring points are indicated by an * alongside the channel value as shown here<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
12. X-Y Analysis<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 98/133<br />
The XY window allows any one channel to be used as a reference and a number of other channels to be plotted<br />
against it to analyse relationships.<br />
XY data may be viewed in a number of different ways, as shown below in this example of oil pressure / engine<br />
speed analysis. The diagram clearly shows oil pressure increasing as engine speed increases, this is a simple<br />
example of a relationship.<br />
Important note – When using a layout of graph and XY window the cursor within the XY window will represent the<br />
same data location as the cursor within the graph window, zoom levels are also maintained providing this option is<br />
selected in general setup – see section 6.0<br />
Graph mode selected, with a dot to represent each<br />
corresponding data point.<br />
Percentage mode selected, value shown is the percentage of<br />
time each cell is used within the data set being analysed.<br />
Smooth mode selected, colour depth represents the percentage<br />
of time each cell is used within the data set being analysed.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
12.1 – XY / New – Load - Swap<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 99/133<br />
To create a new XY window, select Graph / XY Analysis / Open from the upper menu, or press this button on the<br />
tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty graph window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
Add channels to this window by Pressing F2 to open the data browser and ‘drag N drop’ any channel into the<br />
window.<br />
Tip – Any highlighted XY window may be swapped for any other XY window using the CTRL-D keyboard shortcut.<br />
The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 100/133<br />
12.2 – XY / Window layout<br />
In this example, 4 channels are being plotted against the single reference channel - RPM<br />
Primary reference channel, all other<br />
data is plotted against this channel<br />
Secondary<br />
channels<br />
Channel<br />
scales<br />
Min scale<br />
being applied<br />
Time or<br />
Distance<br />
scale<br />
Data set being viewed<br />
Scale for reference channel<br />
Individual channels may be singles out by right clicking, and then press View to open this<br />
next window. This window shows all of the Secondary channels, choose which one you<br />
want to single out for separate analysis.<br />
By pressing the OILP channel<br />
selection all other secondary<br />
channels have been hidden<br />
from view temporarily as<br />
shown here.<br />
To return to the view of all channels, right click any<br />
channel name, select View, and then All Graphs<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 101/133<br />
12.3 – XY / Properties - Window<br />
To access the Properties of the XY window, click your mouse into any central location within the XY window and<br />
then press this button on the lower tool bar. You will notice that the lower tool bar changes depending on the type of<br />
window you are working in.<br />
Style of<br />
display, see<br />
section 12.0<br />
Display style<br />
Parallel<br />
Overlay<br />
Manual<br />
See section 12.6<br />
Load an alternative XY configuration<br />
Save the current configuration as an alternative name.<br />
Clear all loaded channels<br />
Remove the single highlighted channel<br />
Opens the channel browser to load another channel<br />
Move the channel up / Down<br />
within the graph window<br />
Choose the number of grid<br />
divisions<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 102/133<br />
12.4 – XY / Properties - Channel<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties. The following window is displayed.<br />
Important – The reference channel does not have any Property settings for Style, Best Fit or Interpolation<br />
Choose a colour<br />
Style – see below<br />
Best Fit – see<br />
section 12.8<br />
Interpolation – see<br />
section 12.7<br />
Manual scale - see<br />
section 12.5<br />
Channel name<br />
Select a Conditional channel – 24.2<br />
Skip to next channel<br />
Dot size<br />
Dot colour<br />
Manual positioning - see<br />
section 12.6<br />
Marker styles = Line, a line is used to join sequential data acquisition points.<br />
Marker styles = Dot, a single dot is used to indicate each data acquisition point.<br />
Marker styles = Marker, a single ‘cross hair’ is used to indicate each data acquisition point.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 103/133<br />
12.5 – XY / Properties / Channel - Manual scaling<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties. The following window is displayed.<br />
The Manual scaling is used to fix the Min / Max scale values used for any given channel within the XY window, if this<br />
setting is left un-checked, automatic scaling will be applied.<br />
Tick this box to apply a manual fixed<br />
channel scale. Note that this setting<br />
only applies to this XY window and not<br />
any other XY window.<br />
Choose Min and Max values to suit<br />
your data<br />
Choose the number of scale divisions<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 104/133<br />
12.6 – XY / Properties / Channel - Manual positioning<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties.<br />
The Manual positioning is used when multiple secondary channels are being overlaid onto the single reference<br />
channel. In this example, RPM is the reference<br />
channel, OILP and SPEED and the secondary<br />
channels. The default XY window property setting for<br />
this is Overlay to produce a window as shown here.<br />
To use manual scaling, first change the XY window<br />
properties to Manual layout and then adjust each<br />
individual channel to use as much space as you<br />
choose. The following settings will produce an XY<br />
window as shown at the bottom of this page.<br />
Resulting XY layout<br />
OILP channel set to<br />
50 > 100%<br />
SPEED channel set<br />
to 0 > 50%<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 105/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 106/133<br />
12.7 – XY / Properties / Channel - Interpolation<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties.<br />
For channels which have a limited number of acquisition points it can be very difficult to visualise the relationship<br />
trends within the XY window. For this reason the Interpolate function fills in the missing areas to an amount specified<br />
by you.<br />
The reverse of this allows channels with a high frequency and a great many data points to be reduced to a lower<br />
frequency.<br />
From the channel properties window, use the pull down menu to choose the amount of interpolation.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 107/133<br />
12.8 – XY / Properties / Channel – Best Fit<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties.<br />
To visualise the relationship a ‘Best Fit’ option will draw a line presuming the optimum fit, from the channel<br />
properties window, select the best fit from the pull down menu.<br />
The following examples show the differences between different best fit settings with the same data set.<br />
Best fit 1 st setting<br />
Best fit 2 nd setting<br />
Best fit 3 rd setting<br />
Best fit 4 th setting<br />
Best fit 5 th setting<br />
Best fit 6 th setting<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
13. XYZ Analysis window<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 108/133<br />
The XYZ window allows any one channel to be used as a reference, a second channel plotted against it to display a<br />
relationship and a third channel overlaid onto this data as different colours.<br />
XYZ data may be viewed in 2 different ways, as shown below in this example of Time / Y- later al G and oil pressure.<br />
The diagram clearly shows a lateral G trace (Y) with the oil pressure overlaid as different colours.<br />
Important note – When using a layout of graph and XY window the cursor within the XY window will represent the<br />
same data location as the cursor within the graph window, zoom levels are also maintained providing this option is<br />
selected in general setup – see section 6.0<br />
Marker mode selected, with a dot to represent each<br />
corresponding data point.<br />
Smooth mode selected, value shown is the percentage<br />
of time each cell is used within the data set being<br />
analysed.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
13.1 – XYZ / New – Load - Swap<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 109/133<br />
To create a new XY window, select Graph / XYZ Analysis / Open from the upper menu, or press this button on the<br />
tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty graph window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
Add channels to this window by Pressing F2 to open the data browser and ‘drag N drop’ any channel into the<br />
window.<br />
Tip – Any highlighted XYZ window may be swapped for any other XY window using the CTRL-D keyboard shortcut.<br />
The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 110/133<br />
13.2 – XYZ / Window layout<br />
In this example, 4 channels are being plotted against the single reference channel - RPM<br />
Secondary<br />
channel - Y<br />
Channel scale<br />
Values of primary and secondary<br />
channel at cursor position<br />
Third channel - Z<br />
Colour layers<br />
& scale<br />
Data set being viewed Scale for reference channel Primary reference channel - X, all<br />
other data is plotted against this<br />
channel<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 111/133<br />
13.3 – XYZ / Properties - Window<br />
To access the Properties of the XYZ window, click your mouse into any central location within the XYZ window and<br />
then press this button on the lower tool bar. You will notice that the lower tool bar changes depending on the type of<br />
window you are working in.<br />
Display style<br />
Marker<br />
Smooth<br />
See section 13.0<br />
Interpolation – see<br />
section 13.5<br />
Best fit – see section<br />
13.6<br />
Z scale – see<br />
section 13.7<br />
Opens the channel browser to<br />
Conditional channels – see<br />
section 24.2<br />
Load an alternative XYZ<br />
configuration<br />
Save the current configuration<br />
as an alternative name.<br />
Clear all loaded channels<br />
Remove the single highlighted<br />
channel<br />
Move the channel up / Down<br />
within the graph window<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 112/133<br />
13.4 – XYZ / Properties – Channel & manual scaling<br />
Each channel has a unique set of properties that are shown by right clicking the channel name and selecting<br />
Properties. The following window is displayed.<br />
Properties for Reference channel – X<br />
Channel name<br />
Tick to activate the<br />
manual scale range<br />
Swap to next channel<br />
Choose the number of scale divisions<br />
The Manual scaling is used to fix the Min / Max scale values used for any given channel within the XYZ window, if<br />
this setting is left un-checked, automatic scaling will be applied.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 113/133<br />
13.5 – XYZ / Properties / Channel - Interpolation<br />
Within the XYZ window properties it is possible to apply an Interpolation to the visible data.<br />
For channels which have a limited number of acquisition points it can be very difficult to visualise the relationship<br />
trends within the XYZ window. For this reason the Interpolate function fills in the missing areas to an amount<br />
specified by you.<br />
The reverse of this allows channels with a high frequency and a great many data points to be reduced to a lower<br />
frequency.<br />
From the XYZ properties window, use the pull down menu to choose the amount of interpolation.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 114/133<br />
13.6 – XYZ / Properties / Channel – Best Fit<br />
To visualise the relationship a ‘Best Fit’ option will draw a line presuming the optimum fit, from the XYZ properties<br />
window, select the best fit from the pull down menu.<br />
Best fit 1 st setting<br />
Best fit 2 nd setting<br />
Best fit 3 rd setting<br />
Best fit 4 th setting<br />
Best fit 5 th setting<br />
Best fit 6 th setting<br />
Note – With Best Fit active, your cursor will be locked onto the visible line.<br />
The following examples show the differences between different<br />
best fit settings with the same data set.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 115/133<br />
13.7 – XYZ / Properties / Z scale<br />
The channel defined as Z uses colours to display the data as an overlay onto the X and Y channels. The number or<br />
colour divisions, the value at each division and the colours allocated to each division are by default set to automatic.<br />
To change these settings, first open the XYZ properties window and then select Manual from the pull down menu<br />
shown here.<br />
You are free to enter your own<br />
division values<br />
This button will load a set of default<br />
values based on the channel max /<br />
Min<br />
This button will load a set of default<br />
colours<br />
Double clicking any colour<br />
will open the colour pallet<br />
as shown here<br />
Note : The number of<br />
divisions is dictated by the<br />
quantity selected within the<br />
Z channel properties<br />
When manual is selected this Bins<br />
button will become highlighted. Press<br />
this to open the following window.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 116/133<br />
13.8 – XYZ / Zoom<br />
Unlike any other analysis window, the XYZ window may be zoomed in using a ‘box’ operation. From the lower tool<br />
bar select this option.<br />
It is now possible by clicking and holding the left mouse button to create a box around the area you want to zoom<br />
into.<br />
To return to a full view, press this button on the tool bar.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 117/133<br />
13.9 – XYZ / Rotate<br />
The Rotate option allows you to switch around your chosen channel set by moving upwards by a step of 1 as shown<br />
in the following example. To carry out this operation, press this button on the lower tool bar.<br />
A single rotation will result in the following<br />
A further single rotation will result in the following<br />
X channel = RPM<br />
Y channel = OILP<br />
Z channel = OILT<br />
X channel = OILT<br />
Y channel = RPM<br />
Z channel = OILP<br />
X channel = OILP<br />
Y channel = OILT<br />
Z channel = RPM<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
14. Histogram analysis window<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 118/133<br />
The Histogram window allows any channel to be viewed as a histogram. The user is given full control over the<br />
display type and the amount of data represented. Comparison data is also supported.<br />
Histograms may be viewed as either Horizontal or Vertical as shown in the examples below.<br />
Important note – When using a layout of graph and Histogram window the zoom levels are maintained providing<br />
this option is selected in general setup – see section 6.0<br />
Horizontal mode selected<br />
Vertical mode selected<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
14.1 – Histogram / New – Load - Swap<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 119/133<br />
To create a new Histogram window, select Graph / Histogram Window / Open from the upper menu, or press this<br />
button on the tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty graph window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
Add a channel to this window by Pressing F2 to open the data browser and ‘drag N drop’ any channel into the<br />
window.<br />
Tip – Any highlighted Histogram window may be swapped for any other Histogram window using the CTRL-D<br />
keyboard shortcut. The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 120/133<br />
14.2 – Histogram / Window layout<br />
In this example an RPM channel is being viewed as usage percentage within the current data set.<br />
Time or<br />
percentage<br />
scale<br />
Data set being viewed<br />
Percentage values / Can also be<br />
shown as Time<br />
Scale for channel selected<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 121/133<br />
14.3 – Histogram / Properties<br />
Because the Histogram is only able to analyse a single channel, the properties for both the channel and the<br />
Histogram window are bundled together in a single environment.<br />
With a limited number of options available, there is only one button at the bottom of the screen, press this<br />
to view the Properties.<br />
Conditional channels – see<br />
section 24.2<br />
View data as a<br />
Percentage or<br />
Time<br />
X Scale – see<br />
section 14.4<br />
Clear the selected channel<br />
Load an alternative<br />
Histogram configuration<br />
Save the current<br />
configuration as an<br />
alternative name.<br />
Percent scale – see section<br />
14.5<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 122/133<br />
14.4 – Histogram / Properties / X Scale<br />
The X scale allows you to choose the minimum and maximum range for your data as well as the number of columns<br />
(bins) and the colours to use.<br />
To change these settings, first open the Histogram properties window and then select Manual from the pull down<br />
menu shown here.<br />
Select manual<br />
and enter the<br />
min / max data<br />
range<br />
Choose the<br />
number of<br />
columns<br />
By pressing the Bins button you will be presented with the following window.<br />
Use the default or enter your<br />
own division values<br />
The bins (Columns) button<br />
will become active when the<br />
manual mode is selected<br />
Use to re-calculate the scale<br />
based on your new min /<br />
max values<br />
Apply default colours<br />
Double click to open the<br />
colour pallet<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
14.5 – Histogram / Properties / % Scale<br />
The % scale allows you to choose the vertical percentage scale.<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 123/133<br />
To change these settings, first open the Histogram properties window and then select Manual in the check box<br />
shown below.<br />
Select manual<br />
and enter the<br />
min / max data<br />
range<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
15. Trend analysis<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 124/133<br />
Trend analysis allows you to plot significant data events for any channel against the Lap counter. In this way the<br />
gradual change of value can be seen as a progression, as well as the interaction with other channels. A simple<br />
example of this is a gradual reduction in oil pressure as the oil temperature rises.<br />
To view the entire trend for a session containing multiple laps, it is only necessary to open any one lap.<br />
Comparisons are not supported.<br />
Tip – If a Trend window is open as new data is being captured, the trend will be gradually built lap by lap, by the end<br />
of download you will already have a reasonable indication of engine status without needing further analysis.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
15.1 – Trend / New – Load - Swap<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 125/133<br />
To create a new Trend window, select Graph / Trend Window / Open from the upper menu, or press this button on<br />
the tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty Trend window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
Add a channel to this window by Pressing F2 to open the data browser and ‘drag N drop’ any channel into the<br />
window. Note – The first channel you choose should be the Lap count or any other channel, which contains the<br />
source of the trend increment.<br />
Tip – Any highlighted Histogram window may be swapped for any other Trend window using the CTRL-D keyboard<br />
shortcut. The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 126/133<br />
15.2 – Trend / Window layout<br />
In this example the oil pressure is being viewed alongside the oil temperature data with 4 lap data points.<br />
Channel name,<br />
scale and data type;<br />
double click to open<br />
channel properties<br />
Source channel for<br />
incremental trend count<br />
Percentage values / Can also be<br />
shown as Time<br />
Data window<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 127/133<br />
15.3 – Trend / Properties / Window<br />
To access the Properties of the Trend window, click your mouse into any central location within the Trend window<br />
and then press this button on the lower tool bar. You will notice that the lower tool bar changes depending on the<br />
type of window you are working in.<br />
Add a new channel<br />
Add data file information<br />
Loaded channels<br />
Choose the number of laps<br />
to include in the scan,<br />
leave blank to include all<br />
Use this select button to choose<br />
the types of laps to include in the<br />
scan<br />
Load an alternative XYZ<br />
configuration<br />
Save the current configuration<br />
as an alternative name.<br />
Clear all loaded channels<br />
Remove the single highlighted<br />
channel<br />
Move the channel up / Down<br />
within the graph window<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 128/133<br />
15.4 – Trend / Properties / Channel<br />
To access the Properties of the Trend window, click your mouse into any central location within the Trend window<br />
and then press this button on the lower tool bar. You will notice that the lower tool bar changes depending on the<br />
type of window you are working in.<br />
Channel name<br />
Channel data<br />
representation – see below<br />
Channel colour<br />
Channel style – see below<br />
Use automatic or manual<br />
scaling<br />
Double click any channel to open the<br />
individual channel properties<br />
The channel Type representation is used to best show the value trend change.<br />
Min ............................. Tags the minimum value seen during the lap<br />
Max ............................ Tags the maximum value seen during the lap<br />
Avg............................. Tags the Average value seen during the lap<br />
Start ........................... Tags the first data point of the lap<br />
Finish ......................... Tags the last data point of the lap<br />
T1............................... See section 24.3<br />
T2............................... See section 24.3<br />
Line style<br />
Dot style<br />
Marker style<br />
Symbol style<br />
Swap to data file info<br />
Change channel<br />
All other styles are made up of<br />
assemblies of line types and marker<br />
types.<br />
Move to next channel<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 129/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
16. Lap report<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 130/133<br />
The lap report allows you to view significant data events for any channel as a lap-by-lap report. In this way you are<br />
able to create custom printable reports of data events. The same channel may be loaded several times within the<br />
same report to show a different type of data for that channel.<br />
To view the entire lap report for a session containing multiple laps, it is only necessary to open any one lap.<br />
Comparisons are not supported.<br />
Tip – If a Lap Report window is open as new data is being captured, the report will be gradually built lap by lap, by<br />
the end of download you will already have a reasonable indication of engine status without needing further analysis.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
16.1 – Lap Report / New – Load - Swap<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 131/133<br />
To create a new Lap Report window, select Graph / Lap Report / Open from the upper menu, or press this button on<br />
the tool bar.<br />
You will be presented with the normal ‘file open’ window as shown here. Either select an existing file or type a new<br />
file name to create a new and empty Lap report window. You will now be presented with a blank window with your<br />
chosen file name at the top.<br />
Add a channel to this window by Pressing F2 to open the data browser and ‘drag N drop’ any channel into the<br />
window.<br />
Tip – Any highlighted Lap Report window may be swapped for any other Lap Report window using the CTRL-D<br />
keyboard shortcut. The size and position of the original window will be retained.<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
16.2 – Lap Report / Window layout<br />
In this example several channels have been loaded and are being viewed over 4 laps.<br />
Icon indication the<br />
current loaded lap<br />
Report information – user selectable<br />
DATAVIEW Pg. 132/133<br />
Channel names, double click to<br />
open the properties<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa
R&S Business Unit Automotive<br />
17. Circuit window<br />
18. PSD analysis<br />
19. Numeric table<br />
20. Mapping split data<br />
21. Screen layout<br />
22. Telemetry<br />
23. Mathematical channels<br />
24. Miscellaneous<br />
25. Print<br />
26. Tool bars<br />
Via L.Romagnoli, 24 - 41033 Concordia sulla Secchia (Modena) Italy<br />
Tel.: +39 0535 57711 (r.a.) - Fax.: +39 0535 54550<br />
Uffici amministrativi: Via G. Brodolini, 35 - Fax.: +39 0535 54533<br />
Email : guest@digitek.it - Internet : http://w w w .digitek.it<br />
DATAVIEW Pg. 133/133<br />
data view_std_manual v1.4.doc Digitek Spa Digitek Spa