48<br />

Histology & Microscopy<br />

<strong>BioSciences</strong><br />

Spurr Low Viscosity Embedding Kit HMV7g ....................................<br />

Exceptional penetration for tissue, mineral, and dense structures. A low viscosity<br />

of 60cps allows easy penetration into a variety of difficult materials. May<br />

be used to prepare mineral specimens for polishing. The low viscosity of the<br />

Spurr formulation allows rapid infiltration into tissues, minerals and other dense<br />

structures. Facilitates embedments with high lipid contents or hard membranes<br />

or highly vacuolated parenchymatous tissues. Technical Data Sheet #127<br />

Kit Contains: 450g NSA, 250g ERL 4221, 250g D.E.R. 736, 100g DMAE<br />

Spurr Low Viscosity Mini Kit HMV7g ..........................................<br />

Exceptional penetration for tissue, mineral, and dense structures. A low viscosity of 60cps allows<br />

easy penetration into a variety of difficult materials. May be used to prepare mineral specimens for<br />

polishing. The low viscosity of the Spurr formulation allows rapid infiltration into tissues, minerals,<br />

and other dense structures. Facilitates embedments with high lipid contents or hard membranes or<br />

highly vacuolated parenchymatous tissues. Technical Data Sheet #472D<br />

Kit Contains: 55ml NSA, 20ml ERL-4221, 12ml DER736, 1ml DMAE, 3 x 10ml syringes, 1 x 5ml<br />

graduated syringe and 2 wooden mixers<br />

Ultra Low Viscosity Embedding Kit EHOV7g ....................................<br />

ERL-4221 is useful for rapid embedding of materials which are difficult to infiltrate even with<br />

Spurr’s resin. Exhibits good sectioning qualities, beam stability, and staining properties. Miscible<br />

with alcohol or acetone so propylene oxide can be avoided. For EM and LM - NOT water soluble.<br />

Technical Data Sheet #354<br />

Kit Contains: 1 x 100g ERL-4221, 2 x 100g Octenyl Cuccinic Anhydride (DSA), 1 x 25g 1,4-Butanediol<br />

Diglycidyl Ether (BDE) and 1 x 100g Dimethylaminoethanol (DMAE).<br />

Lowicryl ® Embedding Kits<br />

Manufactured by <strong>Polysciences</strong>, these kits were developed in cooperation with the University of<br />

Basel, Switzerland. MonoStep K4M and MonoStep HM20 offer a convenient single bottle of material<br />

for Polar -35°C and Non-polar -70°C applications. Photopolymerization is by long wavelength<br />

(360nm) UV. Polymerization can take place at -70°C or at room temperature with UV light. Lowicryl<br />

gives enhanced preservation of protein molecules wand membrane structures. It is a methacrylate<br />

based, UV curing resin. All kits are useful for freeze-substituted samples. Resins should be used at<br />

maximum temperature of -20°C to minimize disruption of proteins. Lowicryl embedments have<br />

been reported to have rougher surfaces than epoxy embedments yielding more antigen at the section<br />

surface. Metal stains with Lowicryl are superior to uranyl and lead combinations.<br />

Technical Data Sheet #248 J. EM Techniques, 11, 1099 (1989); 18, 172 (1991); J. Histochem. 40, (1), 123 (1992)<br />

Lowicryl ® HM 23 Non-polar, hydrophobic, -80ºC embedding kit CHIR7c ............<br />

Lowicryl ® HM kits are non-polar and are used to produce high contrast images of completely unstained<br />

thin sections by Z-contrast. Also these HM kits are particularly suitable for dark field observation<br />

because of their relatively low density. Technical Data Sheet #248<br />

Kit Contains: 3 x 225 gm of monomer G, 1 x 40gm of crosslinker F, 1 x 3.7gm of initiator C and<br />

1 x 5.5gm of initiator J. Instructions included.<br />

Lowicryl ® K11M Polar Kit, hydrophilic, -60ºC embedding kit ......................<br />

Lowicryl ® K kits are polar and therefore hydrophilic. During dehydration and infiltration<br />

specimens may be kept partially hydrated since polymerization can occur with up to 5%<br />

water. Thus immunolabeling with polar kits results in better preservation of structure and<br />

antigenicity with lower background labeling. Technical Data Sheet #248<br />

Kit Contains: 3 x 250gm of monomer I, 1 x 40gm of crosslinker H and 1 x 4.3 gm of initiator C.<br />

For more information please call (800) 523-2575 or visit: polysciences.com<br />

Microscopic blood clot in<br />

glomerulus of the human kidney<br />

after transplant. Courtesy<br />

of P.Wills, Harris Medical Labs<br />

Catalog # Size<br />

01916-1 1 kit<br />

21961-1 1 kit<br />

17706-1 1 kit<br />

18162-1 1 kit<br />

18163-1 1 kit