Histology & Microscopy<br />

<strong>BioSciences</strong><br />

Vibratome Injector Blades ...................................................<br />

Disposable Injector blades for Vibratome, uncoated carbon.<br />

Mounting Media<br />

Adhesive, Tissue-Tack H5gm ................................................<br />

For adhering tissue sections to slides during immunostaining & routine histology staining procedures.<br />

Technical Data Sheet #289 Stain Technol., 6, 358 (1982)<br />

Aqua-Poly/Mount A2d ......................................................<br />

n20<br />

D 1.454 - 1.460 Viscosity 390 cps<br />

Water-Soluble, Non-Fluorescing Mounting Medium<br />

Formulated for mounting sections from aqueous solutions. Useful for immunofluorescent<br />

techniques as it enhances and retains fluorescent stains. Aqua-Poly/<br />

Mount can also be used for frozen sections, fat stains and immuno-stains when<br />

aqueous mounting media is required. Use Aqua-Poly/Mount with most fluorescent<br />

dyes and stains including DAB, Alkaline Phosphatase-Fast Red, AEC (aminoethylcarbazole)<br />

and a variety of other chromogens. Can be removed from<br />

slides by soaking in water. Supplied in convenient 20ml squeeze bottles.<br />

Technical Data Sheet #521<br />

Cedarwood oil EH2ag .......................................................<br />

n20<br />

D approx. 1.519<br />

Used as immersion oil for light microscopy and for clearing microscope sections.<br />

CitraMount Medium CH5g .................................................<br />

n20<br />

D 1.484 Viscosity 90 cps<br />

This butyl acetate and acrylic mixture is the first mounting medium developed that<br />

allows coverslipping directly from d-limonene based clearants. Superior results are also<br />

obtained with xylene. Recommended for manual coverslipping only as it may cause<br />

damage to the valves of automated coverslippers. Get a clear seal and decrease your<br />

drying time to less than 24 hours. Technical Data Sheet #603<br />

CMCP macroinvertebrate mounting media BHX6g<br />

n20<br />

D 1.41<br />

Colorless non-resinous, water miscible mounting medium for permanent transparent mounts. It<br />

can be used like Canada Balsam, but CMCP resin has the advantage of allowing live or preserved<br />

specimens to be mounted directly from water or alcohol. Useful in mounting free living nematodes<br />

and live parasitic worms. Technical Data Sheet #432 Requires Poison Pack.<br />

CMCP-9 Low viscosity mountant .............................................<br />

CMCP-10 High viscosity mountant ............................................<br />

Immersion Oil – Fluorescence Microscopy – Type LDF ............................<br />

<strong>Polysciences</strong>, PCB-free immersion oils are available according to your specific application.<br />

Manufactured by Cargille. Has highest resolution, but slight green range background<br />

fluorescence. Replaces type DF<br />

Catalog # Size<br />

22370-1 1000<br />

blades<br />

16672-100 100 ml<br />

16672-500 500 ml<br />

18606-20 20 ml<br />

18606-100 100 ml<br />

18606-5 5x20 ml<br />

04851-4 4x100 g<br />

24214-100 100 ml<br />

24214-500 500 ml<br />

16299-100 100 ml<br />

16299-500 500 ml<br />

16300-250 250 ml<br />

16300-500 500 ml<br />

25354-1 1 oz<br />

25354-4 4 oz<br />

For more information please call (800) 523-2575 or visit: polysciences.com 43