Flow Cytometry<br />

Microspheres & Particles<br />

Catalog # Size<br />

Antibody Binding Standards<br />

Antibody Binding Standards are particles which have ligands covalently linked to their surfaces<br />

to bind specific proteins (e.g. Mouse IgG antibodies) in calibrated quantities.<br />

Tests<br />

Simply Cellular ® anti-Mouse IgG 20 BLI810A-1 1 ml<br />

100 BLI810B-5 5 ml<br />

280 BLI810C-14 14 ml<br />

Simply Cellular ® anti-Human IgG 20 BLI812A-1 1 ml<br />

100 BLI812B-5 5 ml<br />

280 BLI812C-14 14 ml<br />

Simply Cellular ® anti-Rat IgG 20 BLI813A-1 1 ml<br />

100 BLI813B-5 5 ml<br />

280 BLI813C-14 14 ml<br />

QuickCal ® v. 2.3 Data Analysis Program<br />

QuickCal ® constructs a calibration curve associating fluorescence channel values to standardized<br />

fluorescence intensity units. Additionally, the channel value corresponding to the kit’s blank bead<br />

is converted to the appropriate standardized fluorescence intensity unit (MESF or ABC); this will be<br />

the instrument’s detection threshold for the specific reporter and detector. For instructions regarding<br />

QuickCal ® , please see Bangs’ Product Data Sheet 819, QuickCal ® v. 2.3 Data Analysis Program.<br />

Applications<br />

Size Calibration<br />

Size Calibration Standards Kit<br />

The Size Calibration Standards Kit includes five highly uniform unlabeled microbead populations<br />

of different diameters (~4-11µm), which can be used to construct calibration plots for electronic<br />

volume and light scatter instrumentation.<br />

Tests<br />

100 BLI829B-5 5 ml<br />

280<br />

Count Standards<br />

Flow Cytometry Absolute Count Standard<br />

BLI829C-14 14 ml<br />

A2adm<br />

Consists of highly uniform cell-sized microspheres labeled with a full spectrum dye and provided<br />

at a known concentration (~1 x106 ). These beads fluoresce over a broad range of the spectrum,<br />

allowing them to be used as count standards in multiple detectors.<br />

Tests<br />

20 BLI580-10 10 ml<br />

Suspension Arrays<br />

Suspension arrays for the flow cytometer feature populations of microspheres coated with different<br />

ligands for the interrogation of multiple targets within a given sample. Ligand-specific microsphere<br />

populations are encoded so that results for corresponding individual targets may be discerned.<br />

Encoding may be in the form of microsphere size and/or fluorescence signature, as with our<br />

QuantumPlex and QuantumPlex M platforms.<br />

QuantumPlex <br />

The microsphere populations in QuantumPlex five-bead kits are encoded with different intensities<br />

of Starfire Red , and microspheres in our ten-bead kits are distinguished by both fluorescence<br />

intensity and size. Starfire Red is a fluorescent dye with unique characteristics that make it ideal<br />

for multiplexing applications. The dye’s broad excitation band allows it to be excited at a number<br />

of wavelengths, and it emits in the red channel (e.g. PE-Cy 5, APC) with very little carry-over into<br />

lower wavelengths, leaving other detectors available for determination of positive binding events<br />

via common reporters such as FITC and PE.<br />

QuantumPlex kits are available with three different surfaces to accommodate the coating strategy<br />

of choice: carboxyl, streptavidin or anti-Mouse IgG.<br />

For more information please call (800) 523-2575 or visit: polysciences.com 277