Flow Cytometry<br />

Microspheres & Particles<br />

Catalog # Size<br />

New! Simply Cellular ® anti-Mouse for Violet Laser<br />

Features microspheres comprised of a proprietary matrix that exhibits low autofluorescence with violet<br />

excitation. Beads are suitable for labeling with mouse Abs conjugated with violet fluorochromes,<br />

and for use as a compensation or general reference standard for detectors off of the violet laser.<br />

Beads are also suitable for use with other fluorochromes/detectors, e.g. 488nm, 633nm. The Simply<br />

Cellular ® anti-Mouse for Violet Laser standard is supplied as 2 populations: 1 blank and 1 highbinding<br />

anti-Mouse IgG (Fc specific) population. Supplied in aqueous suspension containing ProClin ® .<br />

Tests<br />

Simply Cellular ® anti-Mouse for Violet Laser 20 BLI835A-1 1 ml<br />

100 BLI835B-5 5 ml<br />

FITC/PE Compensation Standard<br />

The FITC/PE Compensation Standard is a convenient means of setting two color compensation on a<br />

flow cytometer. Each kit contains an Autofluor bead, as well as a bead labeled with FITC, a bead<br />

labeled with PE and a bead labeled with both FITC and PE.<br />

Tests<br />

FITC/PE Compensation Standard 20 BLI820A-1 1 ml<br />

100 BLI820B-5 5 ml<br />

280 BLI820C-14 14 ml<br />

Flow Cytometry Antibody Binding Beads<br />

Single population Protein A or Protein G microspheres are suitable for labeling with conjugated<br />

antibodies from a range of hosts. Labeled microspheres may be used as single-population reference<br />

standards or in conjunction with an unlabeled population for compensation purposes.<br />

Tests<br />

Flow Cytometry Protein A Antibody Binding Beads 20 BLI553-1 1 ml<br />

100 BLI553-5 5 ml<br />

280 BLI553-14 14 ml<br />

Flow Cytometry Protein G Antibody Binding Beads 20 BLI554-1 1 ml<br />

100 BLI554-5 5 ml<br />

280 BLI554-14 14 ml<br />

New! Viability Dye Compensation Standard<br />

Viability Dye Compensation Standards are suitable for labeling with LIVE/DEAD ® stains or similarilyreactive<br />

dyes to generate compensation standards for flow cytometric analyses. Beads are not<br />

suitable for labeling with DNA stains such as propidium iodide, DAPI, or Sytox ® , and users should<br />

contact us for discussion if uncertain as to the compatibility of a specific dye or stain.<br />

Nom. Dia.<br />

Viability Dye Compensation Standard 4µm BLI450-3 3ml<br />

Viability Dye Compensation Standard 8µm BLI451-3 3ml<br />