Flow Cytometry<br />

Bangs Flow Cytometry Standards<br />

Microspheres & Particles<br />

In order to perform reliable flow cytometric analyses, the instrument must be properly set up and<br />

its performance validated. Bangs Flow Cytometry Standards are designed to help achieve these<br />

goals and are presented in the following categories: Instrument Set-Up, Calibration, Validation and<br />

Fluorescence Quantitation. Most of the Bangs Flow Cytometry Standards are available in three<br />

convenient sizes: Trial (A Size: 20 tests, 1ml), Standard (B Size: 100 tests, 5ml) and Economy (C<br />

Size: 280 tests, 14ml). A test requires one drop (50µl) of particle suspension, which is equivalent<br />

to ~100,000 particles. Bangs Flow Cytometry Standards are ~7-9µm in diameter (unless otherwise<br />

noted) to approximate the size of human lymphocytes. QuantumPlex kits for particle-based suspension<br />

assays are also featured in this section.<br />

Instrument Set-up<br />

General Fluorescence Reference Standards<br />

Full Spectrum Multi-color Reference Standards are highly uniform microspheres which fluoresce over a broad range<br />

of the spectrum to provide several reference positions in multi-detector analysis. Used to properly<br />

align flow cytometers excited from UV to near IR, this standard emits over the entire spectrum.<br />

Catalog # Size<br />

Tests<br />

20 BLI885A-1 1 ml<br />

100 BLI885B-5 5 ml<br />

280 BLI885C-14 14 ml<br />

Ultra Rainbow Fluorescent Particles<br />

Internally labeled with a mixture of fluorophores which enables them to be excited at wavelengths<br />

from 365nm to 650nm.<br />

Tests Nom. Dia.<br />

Ultra Rainbow Fluorescent Particles 20 ~3.8µm BLI610A-1 1 ml<br />

100 BLI610B-5 5 ml<br />

280 BLI610C-14 14 ml<br />

Ultra Rainbow Fluorescent Particles 20 ~10.2µm BLI611A-1 1 ml<br />

100 BLI611B-5 5 ml<br />

280 BLI611C-14 14 ml<br />

Time Delay Calibration Standard .............................................<br />

Intended for use in assessing the delay between blue and red lasers. It features ~6µm microspheres<br />

dyed with a fluorophore that is excited with 488nm or 635nm excitation and exhibits red/far-red<br />

emission.<br />

BLI830A-1 1 ml<br />

BLI830B-5 5 ml<br />

BLI830C-14 14 ml<br />

Fluorescence Reference Standards<br />

Fluorescence Reference Standards are labeled with specific fluorochromes so that they give rise to<br />

the same fluorescence spectra as cells labeled with the same fluorochromes. Fluorescence intensity<br />

is similar to biological samples.<br />

Tests<br />

Certified Blank (no label) Reference Standard 20 BLI890A-1 1 ml<br />

100 BLI890B-5 5 ml<br />

280 BLI890C-14 14 ml<br />

Autofluor Reference Standard 20 BLI910A-1 1 ml<br />

100 BLI910B-5 5 ml<br />

280 BLI910C-14 14 ml<br />

Acridine Orange Reference Standard 20 BLI897A-1 1 ml<br />

100 BLI897B-5 5 ml<br />

280 BLI897C-14 14 ml<br />

For more information please call (800) 523-2575 or visit: polysciences.com 271