fIg.5. Stress distribution (von mieses theory) on<br />

surface of uhmWPE bushings [mPa].<br />

fIg.6. Stress distribution (von mieses theory) on<br />

surface of femoral component [mPa].<br />

Conclusions<br />

One of the most common reasons of joint endoprosthesis<br />

malfunction leading to a reoperation is a mechanical defect<br />

or an implant loosening (or their combination). Appropriate<br />

design of the implant can dramatically eliminate this risk.<br />

As a useful tool for endoprosthesis development, a finite<br />

element method can be used, providing that the anatomical<br />

relation or mechanical test standards are kept.<br />

A goal of this paper was to make up a computer simulation<br />

of oncology knee implant loading during the mechanical<br />

test defined by ISO 14243 [1-3]. The results pointed out the<br />

fIg.7. Stress distribution (von mieses theory) on<br />

surface of tibial stem [mPa].<br />

most critical areas of the endoprosthesis, i.e. UHMWPE<br />

bushings and femoral stem made of titanium alloy. The<br />

analyses made for four degrees of flexion (1.53 deg, 8.13<br />

deg, 15.31 deg and 26.33deg) can be used for simulation<br />

of various designs of the endoprosthesis. Since the oncology<br />

implants are produced as an individual replacement,<br />

finite element method represents a time and money saving<br />

method of the implant production.<br />

acknowledgements<br />

This research is supported by a grant of Ministry of Industry<br />

and Trade of the Czech Republic: MPO FI-IM4/125.<br />

References<br />

[1] ISO 14243-1. Implants for surgery - Wear of total knee-joint<br />

prostheses - Part 1: Loading and displacement parameters for<br />

wear-testing machines with load control and corresponding environmental<br />

conditions for test. 2002.<br />

[2] ISO 14243-2. Implants for surgery - Wear of total knee-joint<br />

prostheses - Part 2: Methods of measurement. 2000.<br />

[3] ISO 14243-3. Implants for surgery - Wear of total knee-joint<br />

prostheses - Part 3: Loading and displacement parameters for<br />

wear-testing machines with displacement control and corresponding<br />

environmental conditions for test. 2004.<br />

[4] Prospon, s.r.o., Jiriho Voskovce 3206, Kladno, 272 01, Czech<br />

Republic. On-line at: