6 EMERGING TECHNIQUES<br />

Chapter 6<br />

This chapter includes novel pollution prevention and control techniques that are reported to be<br />

<strong>und</strong>er development and may provide future cost or environmental benefits. If available, the<br />

information includes the potential efficiency of the techniques, a preliminary cost estimate, and<br />

an indication of the time-scale before the techniques might be commercially “available”.<br />

Established techniques in other sectors that are emerging in practice within the FDM sector are<br />

not included.<br />

6.1 Use of UV/ozone in absorption for odour abatement<br />

Description<br />

Ozone has been used historically as an oxidant in only a limited number of odour control<br />

applications. This is primarily because, although it is extremely reactive in the liquid phase, its<br />

reactivity in the gaseous phase is lower. A process was developed during the 1980s that<br />

enhanced the activity of ozone by the incorporation of UV light. The process uses a<br />

conventional packed bed system and a liquid recycle system. Ozone is bubbled into the sump of<br />

the absorber and the ozonated water is passed through a bank of UV lamps. Ozone in the<br />

presence of UV light produces hydroxyl radicals which are far more reactive than ozone alone.<br />

Dissolved organic compo<strong>und</strong>s in the liquid phase are oxidised to carbon dioxide and water and<br />

thus the absorber liquor discharged from the system is relatively clean.<br />

Achieved environmental benefits<br />

Reduced odour emissions.<br />

Applicability<br />

Ozone systems have not been effective when applied to hot and humid airflows, e.g. when<br />

applied to a poultry processor scald tank vent.<br />

Reference literature<br />

[34, Willey A R and Williams D A, 2001]<br />

RHC/EIPPCB/FDM_BREF_FINAL January 2006 613