Chapter 2<br />

2.1.5.8.3 Description of techniques, methods and equipment<br />

Pasteurisation temperatures commonly range from 62 to 90 °C, and pasteurisation times vary<br />

from seconds to minutes. Batch wise pasteurisation uses a temperature of 62 to 65 °C for up to<br />

30 minutes. High temperature short time (HTST) pasteurisation uses a temperature<br />

of 72 to 75 °C for 15 to 240 seconds. High heat short time pasteurisation (HHST) applies a<br />

temperature of 85 to 90 ºC for 1 to 25 seconds.<br />

Batch wise pasteurisation is carried out in agitated vessels. Sometimes the product, i.e. beer and<br />

fruit juices, is pasteurised after bottling or canning. Here the products in their containers are<br />

immersed in hot water or fed through a steam tunnel. For continuous pasteurisation, flowthrough<br />

heat-exchangers, e.g. tubular, plate and frame, are applied. These have heating, holding<br />

and cooling sections. Table 2.2 shows examples of heat treatment combinations used in the<br />

FDM sector.<br />

Process Heating temperature/<br />

holding time<br />

Use<br />

Bulk liquid pasteurisation 63 °C/30 min Vat pasteurisation of milk<br />

High temperature short time 72 °C/15 s Continuous pasteurisation of<br />

pasteurisation (HTST)<br />

milk for food safety<br />

Cooking of meat products 65 to 75 °C internal Ready-to-eat products, e.g. ham,<br />

temperature<br />

meat loaves and frankfurters<br />

Blanching of vegetables Variable, e.g. 75 °C/5 min Enzyme deactivation and tissue<br />

softening<br />

In-bottle pasteurisation 60 °C/10 min* Shelf-life extension of beer<br />

*the parameter may vary depending on the type of beer<br />

Table 2.2: Examples of heat treatment combinations used in the FDM sector<br />

[1, CIAA, 2002]<br />

Generally for sterilisation, the product is canned or bottled and then heat-treated in a steriliser<br />

with steam or hot water. Sterilisers may be batch or continuous. In sterilisation with moist heat,<br />

temperatures generally range from 110 to 130 ºC with sterilisation times being<br />

from 20 to 40 minutes. For example, canned foods are sterilised in an autoclave at about 121 ºC<br />

for 20 min. Higher temperatures and shorter times may have similar effects, e.g. 134 ºC<br />

for 3 min. However, if conditions do not allow the germination of spores, lower temperatures<br />

and shorter times can also be applied. For example, with acid fruit juices, jam, or desserts,<br />

heating up to 80 to 100 ºC for 10 minutes is normally sufficient.<br />

For killing bacterial endospores by dry heat, longer exposure times and higher temperatures are<br />

required than with moist heat, e.g. up to 2 hours at 160 to 180 ºC. Solutions containing<br />

thermolabile compo<strong>und</strong>s can be sterilised by filtration through mediums such as nitrocellulose<br />

membranes, diatomaceous earth, e.g. kieselguhr, and porcelain. UV irradiation is used to keep<br />

rooms partially sterile. Bacteria and their spores are killed quickly, but fungal spores are only<br />

mo<strong>der</strong>ately sensitive to radiation. Ionising radiation, e.g. X-ray and gamma radiation, is used to<br />

sterilise food and other compact materials. Chemical means may also be applied. Ethylene oxide<br />

is used to sterilise food, plastics, glassware, and other equipment [87, Ullmann, 2001].<br />

UHT treatment means a very short heat treatment at temperatures of 135 to 150 ºC for only a<br />

few seconds. This results in a sterilised product with minimal heat damage to the product<br />

properties. UHT treatment is only possible in flow-through equipment. The product is thus<br />

sterilised before it is transferred to pre-sterilised containers in a sterile atmosphere. This requires<br />

aseptic processing. For UHT treatment, indirect heating in plate and frame or tubular heatexchangers<br />

is applied. Direct steam injection or steam infusion may also be applied.<br />

40 January 2006 RHC/EIPPCB/FDM_BREF_FINAL