Steel DIN frames – Enquiries and orders<br />

1<br />

To make an enquiry or place an order, all you have to do is give us the short name for the frame model. In addition, we need the<br />

following details:<br />

1. Profile name as per catalogue / brochure<br />

2. Sheet metal thickness<br />

3. Frames for rebated or flush door leaves, where applicable citing door thickness / frame rebate depth<br />

4. Plaster edge on rebate side and side opposite rebate<br />

5. Counter-frame on rebate side and side opposite rebate<br />

6. Floor recess<br />

7. Type and number of hinge pockets and, where applicable, distances<br />

8. Handle height, if differing from the standard 1050 mm, in the case of special frame rebate depths please state distance of the<br />

punched latch/bolt hole from the counter-frame to the front edge of the punched area<br />

9. Throat width = wall thickness incl. plaster in mm = finished wall thickness<br />

10. Basic dimensions as per DIN 18100, and/or basic shell dimensions, frame rebate dimensions or door leaf outer<br />

measurements, please always state what is meant (please do not mix different measurement groups, as if you do this inevitably<br />

causes problems!)<br />

11. Stops as per DIN 107 as DIN left or DIN right or as right/left stop<br />

12. Sealing strip: model, quality, colour<br />

13. Other details important for making the frame<br />

14. Shipping address<br />

15. Supplementary details such as telephone or fax number, contact name, special features of the building, etc.<br />

In the case of custom profiles it will be assumed in the absence of any specifications that a difference of 17 mm<br />

exists per stop side between the basic dimensions and the frame rebate dimensions (DIN), except in the case of<br />

gym hall frames.<br />

The frame and door leaf dimensions stated in this table apply only to normal and custom frames if no other details need to be considered!<br />

Door types Basic dimensions Clear frame opening dimensions Frame rebate dimensions Door leaf outer dimensions Door leaf outer dimensions<br />

as per DIN 18100 as per DIN 18111 as per DIN 18111 as per DIN 18101 rebated doors non-rebated doors<br />

Width Height Width Height Width Height Width Height Width Height<br />

Single 875 1875 811 1843 841 1858 860 1860 834 1847<br />

625 2000 561 1968 591 1983 610 1985 584 1972<br />

750 2000 686 1968 716 1983 735 1985 709 1972<br />

875 2000 811 1968 841 1983 860 1985 834 1972<br />

1000 2000 936 1968 966 1983 985 1985 959 1972<br />

Double 1500 2000* 1436 1968 1466 1983 1485 1985 1459 1972<br />

1750 2000* 1686 1968 1716 1983 1735 1985 1709 1972<br />

2000 2000* 1936 1968 1966 1983 1985 1985 1959 1972<br />

The frame and door leaf dimensions stated in this table apply only to industrial normal and custom frames if no other details need to be considered!<br />

Door types Basic dimensions Clear frame opening dimensions Frame rebate dimensions Door leaf outer dimensions Door leaf outer dimensions<br />

as per DIN 18100 as per DIN 18111 as per DIN 18111 as per DIN 18101 rebated doors non-rebated doors<br />

Width Height Width Height Width Height Width Height Width Height<br />

Single 625 2125* 561 2093 591 2108 610 2110 584 2097<br />

750 2125 686 2093 716 2108 735 2110 709 2097<br />

875 2125 811 2093 841 2108 860 2110 834 2097<br />

1000 2125 936 2093 966 2108 985 2110 959 2097<br />

1125 2125 1061 2093 1091 2108 1110 2110 1084 2097<br />

1250 2125* 1186 2093 1216 2108 1235 2110 1209 2097<br />

Double 1500 2125* 1436 2093 1466 2108 1485 2110 1459 2097<br />

1750 2125* 1686 2093 1716 2108 1735 2110 1709 2097<br />

2000 2125* 1936 2093 1966 2108 1985 2110 1959 2097<br />

*Building connections and allocation dimensions not contained in DIN 18100, 18101 and 18111.<br />

Subject to technical changes<br />

1.16.02