Annexes<br />

Emission Limit Values for Specific Materials<br />

Parameter mg/Nm 3<br />

Mass flow threshold for ELVs<br />

Bromine 10 >50 g/h<br />

Chlorine 10 >50 g/h<br />

Iodine 10 >50 g/h<br />

Mercury 0.1 >1 g/h<br />

Total heavy metals 1.5 >5 g/h<br />

Nitrogen oxides (as NO2) 300 >3 kg/h<br />

Sulphur oxides (as SO2) 300 >3 kg/h<br />

Particulates - general 20 >0.5 kg/h<br />

1,1-Dichloroethene 5 >0.1 kg/h<br />

Acrylonitrile 20 >0.1 kg/h<br />

Toluene diisocyanate 1 >0.1 kg/h<br />

Ethyl acrylate 1<br />

b<br />

Isobutyl acrylate 1<br />

b<br />

Methyl acrylate 5<br />

b<br />

n-Butyl acrylate 5<br />

b<br />

t-Butyl acrylate and higher acrylate<br />

esters<br />

a<br />

Dust as active ingredient<br />

b<br />

Only applicable to vents from bulk storage (>20 tonnes)<br />

20<br />

b<br />

Emission Limit Values for General Emissions to Air (excluding Incinerator Emissions) for Materials<br />

not already covered by the Tables above<br />

Constituent group a or<br />

Class Mass flow threshold<br />

parameter<br />

for ELV b<br />

ELV (mg/Nm 3 )<br />

Carcinogenic sub- T.A. Luft I<br />

>0.5 g/h<br />

0.1<br />

stances<br />

T.A. Luft II<br />

>5.0 g/h<br />

1.0<br />

T.A. Luft III<br />

>25.0 g/h<br />

5.0<br />

Substances (other than<br />

those above) with R45<br />

designation<br />

>0.5 kg/h<br />

5.0<br />

Inorganic dust particles T.A. Luft I<br />

>1 g/h<br />

0.2<br />

T.A. Luft II<br />

>5 g/h<br />

1.0<br />

T.A. Luft III<br />

>25 g/h<br />

5.0<br />

Vaporous or gaseous T.A. Luft I<br />

>10 g/h<br />

1<br />

inorganic substances T.A. Luft II<br />

>50 g/h<br />

5<br />

T.A. Luft III<br />

>0.3 kg/h<br />

30<br />

T.A. Luft IV<br />

>5.0 kg/h<br />

500<br />

Organic substances U.K. AEA 1<br />

>0.5 kg/h<br />

20<br />

with photochemical<br />

ozone potential - POCP<br />

U.K. AEA 2<br />

>2.0 kg/h<br />

50<br />

Organic substances c<br />

T.A. Luft I<br />

>0.1 kg/h<br />

20<br />

T.A. Luft II<br />

>2.0 kg/h<br />

100<br />

T.A. Luft III<br />

>3.0 kg/h<br />

150<br />

General dusts 0.5 kg/h<br />

20<br />

Pharmaceutical and<br />

pesticide dust (as active<br />

ingredient)<br />

>1 g/h 0.15<br />

Fugitive emission<br />

d<br />

Footnotes to the table:<br />

a Where a substance falls into more than one category, the lower ELV applies.<br />

b The mass flow is calculated in kg/h for the raw gas and is determined at the point before any<br />

gas cleaning or abatement plant, but after any devices inherent in the process (e.g. after reactor<br />

overhead condensers or after product cyclones). Mass flow is the maximum emission which can<br />

occur over any one hour period of plant operation, from the entire site. Where the mass flow<br />

exceeds the mass threshold, then abatement will be required down to the appropriate ELV,<br />

unless the concentration of the raw gas is already below the ELV, in which case no further<br />

abatement is required.<br />

c Where organic substances of several classes are present, in addition to the above limit, the<br />

sum of classes I and II shall not exceed the class II limit and the sum of classes I, II and III shall<br />

not exceed the class III limit.<br />

418 Waste Water and Waste Gas Treatment