Annexes<br />

D. Requirements on waste water prior to blending<br />

The following requirements shall apply to the waste water prior to blending with other waste<br />

water:<br />

Qualified random sample or 2hour<br />

composite sample<br />

[mg/l]<br />

Random<br />

sample<br />

[mg/l]<br />

Adsorbable organic halogens (AOX) - 0.1<br />

Phenol index after distillation and dye extraction 0.15 -<br />

Benzene and derivatives 0.05 -<br />

Sulphide sulphur and mercaptan sulphur 0.6 -<br />

If hydrocarbon production also includes the manufacture of ethylbenzene and cumene, an AOX<br />

level of 0.15 mg/l shall apply.<br />

E. Requirements on waste water for the site of occurrence<br />

Waste water from the production of ethylbenzene and cumene must not exceed a level of 1 mg/l<br />

for adsorbable organic halogens (AOX) in the random sample.”<br />

7. GREECE<br />

No information supplied.<br />

8. IRELAND<br />

Releases to air:<br />

The reference conditions for concentrations of substances in emissions to air from contained<br />

sources are:<br />

For non-combustion gases: Temperature: 273 K<br />

Pressure: 101.3 kPa<br />

no correction for water vapour<br />

For combustion gases: Temperature: 273 K<br />

Pressure: 101.3 kPa<br />

dry gas<br />

Oxygen content: 3 % (dry) for liquid and gaseous fuel<br />

6 % (dry) for solid fuel<br />

Achievement of emission limit value (ELV) concentrations by the introduction of dilution air is<br />

not permitted.<br />

For continuously monitored emissions, the following will be required for compliance with<br />

measurements based on 30 minute mean values (unless otherwise stated):<br />

i. 97 % of all 30 minute mean measurements shall be below 1.2 times the emission limit<br />

ii. no 30 minute measurement shall exceed 2.0 times the emission limit<br />

iii. all daily mean values shall be less than the emission limit.<br />

Where periodic monitoring is used to check compliance, all samples should meet the consent<br />

conditions.<br />