Annexes<br />

Art. 5.20.3.4 Riser pipe covers<br />

For the avoidance of gas and coal tar emissions, riser pipe covers must be fitted with devices<br />

for keeping wet with water or equivalent devices.<br />

Art. 5.20.3.5 Coke oven operating machines<br />

Coke oven operating machines must be fitted with devices for the cleaning of the sealing surfaces<br />

at the oven door frames.<br />

Art. 5.20.3.6 Coke oven doors<br />

Coke oven doors with a large sealing effect must be used, for example diaphragm doors or<br />

doors with an equivalent sealing effect. The sealing surfaces of the oven doors must be regularly<br />

cleaned.<br />

Unless specified otherwise in the environmental licence, the coke oven batteries are to be arranged<br />

in such a way that on the machine side and on the coke side door extraction units with<br />

dedusting devices can be installed.<br />

Art. 5.20.3.7 Pushing out of coke<br />

With the pushing out of coke the spent gases must be collected and led to a dedusting installation.<br />

Unless specified otherwise in the environmental licence, the dust concentration in the emissions<br />

will not exceed the emission limit value of 50 mg/Nm 3 , and the dust-containing emissions may<br />

not exceed 5 gram per tonne of produced coke.<br />

Art. 5.20.3.8 Coke cooling<br />

§ 1. If dry cooling is applied, unless specified otherwise in the environmental licence, the dust<br />

emissions in the gaseous effluent may not exceed 20 mg/m 3 .<br />

§ 2. If wet cooling is applied, the quenching tower used must be fitted with built-in dust extractors.<br />

As a derogation from the general emission limit values laid down in article 4.4.3.1, the emission<br />

limit values are expressed in gram per tonne of coke. Unless specified otherwise in the environmental<br />

licence, an emission limit value of 60 gram suspended particulates per tonne coke,<br />

measured according to the VDI directive VDI 2303 or another equivalent measuring method<br />

approved by an environmental expert accredited in the discipline air, may not be exceeded.<br />

Art. 5.20.3.9 Operating manual<br />

An operating manual must contain measures for the reduction of emissions with the operation<br />

of the coke oven, in particular regarding:<br />

1. the sealing of the openings<br />

2. the guaranteeing that only fullycoked material will be pushed out<br />

3. the avoidance of unburned gases escaping into the atmosphere.<br />