Art. 5.17.1.3<br />

Annexes<br />

§ 1. Unless specified otherwise in the environmental licence, at the entrance to category 1 establishments<br />

for which article 7 of title I of Vlarem is applicable, an identification and information<br />

sign of at least 1 m 2 must be placed, indicating at least the information below in a clearly<br />

readable way:<br />

1. "VR-PLICHTIG BEDRIJF" (enterprise required to submit a safety report) if in accordance<br />

with article 7 § 3 of title I of VLAREM it concerns an enterprise for which a safety report is<br />

required, or<br />

"GEVAARLIJKE STOFFEN" (hazardous substances), at establishments for which article 7<br />

§ 1 and § 2, of title I of VLAREM is applicable<br />

2. the operator’s name, address and phone number<br />

3. the contact and emergency (fire brigade) phone numbers.<br />

§ 2. At the entrance to establishments for which article 7 of title I of VLAREM is applicable, an<br />

up-to-date site plan of the establishment must be kept inside a fireproof cabinet that is easily<br />

accessible to the emergency services. For all storage facilities for hazardous products at the establishment,<br />

the following information must be clearly<br />

marked on this site plan:<br />

1. the exact location<br />

2. the chemical and/or technical names of the hazardous product, with the specification of the<br />

classification according to EC directives 67/548/EEC of 27 June 1967 or 88/379/EEC of 7<br />

June 1988 and of the UN number<br />

3. the specification whether it concerns storage in:<br />

a) mobile receptacles<br />

b) fixed abovegro<strong>und</strong> containers<br />

c) buried containers<br />

d) containers placed in a trench;<br />

4. the maximum storage capacity in tonnes or m 3<br />

5. the normal storage temperature in °C and the storage pressure in Pa.<br />

§ 3. The cabinet referred to in § 2 bears the notice "GS-SITUATIEPLAN" ("hazardous materials<br />

site plan"), in black letters with a height of at least 8 centimetres on a yellow backgro<strong>und</strong>. If<br />

this cabinet is kept locked, either:<br />

1. the key to the lock in question must be kept next to the cabinet, behind a protective glass<br />

cover that can be broken with a little hammer in an emergency<br />

2. or the cabinet itself must be closed with a protective glass front that can be broken with a<br />

little hammer in an emergency.<br />

§ 4. The conditions specified in § 2 and § 3 may be derogated from if an alternative system is<br />

used that is accepted by the Environmental Licence Department and which offers at least the<br />

same guarantees as regards information.<br />

§ 5. The necessary provisions must be put in place to make the installation inaccessible to unauthorised<br />

persons.<br />

§ 6. The provisions of § 5 are not applicable to storage facilities for liquid fuels which form<br />

part of a fuel distribution installation for motor vehicles.<br />

Art. 5.17.1.4<br />

§ 1. The leak-tightness of the piping, the couplings, the valves and all accessories must be ensured.<br />

They must be protected against corrosion in an effective way.<br />