Annexes<br />

§ 5. At the establishment, the necessary provisions must be present to prevent fire extinguishing<br />

water contaminated with chemicals from draining into the gro<strong>und</strong>, public sewers, surface or<br />

gro<strong>und</strong>water. The collected contaminated fire extinguishing water must be disposed of in an<br />

appropriate fashion. The collection capacity for contaminated fire extinguishing water must be<br />

determined in consultation with the authorised fire brigade.<br />

§ 6. All persons and staff working at the establishment must be fully aware of the nature of the<br />

substances and products manufactured and the dangers involved. Personnel must be well informed<br />

about the measures to be taken when irregularities occur. The operator is to provide upto-date<br />

instructions as required. These instructions must be evaluated by the operator at least<br />

once per year.<br />

Art. 5.7.1.4<br />

§ 1. Unless specified otherwise in the environmental licence and as a derogation from the general<br />

emission limit values specified in chapter 4.4, the emission limit values given below - expressed<br />

in mg/Nm 3 and relating to the following circumstances: temperature 0 °C, pressure<br />

101.3 kPa, dry gas, or wet gas if steam ejectors are used - apply to the waste gases discharged:<br />

The quantities of air supplied to a part of the installation for the dilution or cooling of the waste<br />

gas are not taken into account with the calculation of the emission values.<br />

1. propenenitrile:<br />

� in the gaseous effluent of the combustion plants for the production of propenenitrile, irrespective<br />

of the mass flow: 0.2 mg/Nm 3<br />

� remaining, with a mass flow of 25 g/h or more: 5.0 mg/Nm 3<br />

2. the following organic substance, at a mass flow per substance of 100 g/h or more:<br />

1,2-dichloroethane:<br />

� with the production of this compo<strong>und</strong>: 5.0 mg/Nm 3<br />

� in other cases: 20.0 mg/Nm 3<br />

3. total dust:<br />

plants for the production of biocides or active ingredients thereof, at a mass flow of 25 g/h or<br />

more:<br />

� for highly toxic or highly bioaccumulative and persistent biocides: 5.0<br />

mg/Nm³<br />

� for highly toxic, harmful or corrosive biocides: 20.0 mg/Nm³<br />

� for non-harmful biocides: 100.0<br />

mg/Nm³<br />

§ 2. Gaseous effluents are to be collected at the place they originate and, after any necessary<br />

purification for compliance with the prevailing emission and immission conditions, discharged<br />

into the ambient air through a chimney stack. This chimney stack must be sufficiently tall to,<br />

from an environmental perspective, adequately disperse the discharged substances and not affect<br />

public health. The minimum height must be determined in accordance with the chimney<br />

stack height calculation system as specified in art. 4.4.2.3.<br />

Section 5.7.2 The production of titanium dioxide<br />

Art. 5.7.2.1<br />

The provisions of this section are applicable to the establishments referred to in subsection 7.1<br />

of the classification list, as far as these establishments belong to the sector of titanium dioxide<br />

production.<br />