10.07.2015 Aufrufe

Finish 270 Finish 250 - Wagner

Finish 270 Finish 250 - Wagner

Finish 270 Finish 250 - Wagner

MEHR ANZEIGEN
WENIGER ANZEIGEN

Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.

YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.

GB<strong>Finish</strong> <strong>270</strong> / <strong>250</strong>Safety regulations1.8 Prevention of occupational illnessesProtective clothing, gloves and possibly skin protection creamare necessary for the protection of the skin.Observe the regulations of the manufacturer concerning coatingmaterials, solvents and cleaning agents in preparation,processing and cleaning units.1.9 Max. operating pressureThe permissible operating pressure for the spray gun, spraygun accessories, unit accessories and high-pressure hosemust not fall short of the maximum operating pressure of 25MPa (<strong>250</strong> bar or 3625 psi).1.10 High-pressure hose (safetyinstructions)An electrostatic charging of spray guns and the high-pressurehose is discharged through the high-pressure hose. For thisreason the electric resistance between the connections of thehigh-pressure hose must be equal to or lower than 1 MΩ.Only use WAGNER original-high-pressurehoses in order to ensure functionality, safetyand durability.1.14 Suction installationsThe are to be provided by the unit user in accordance with thecorresponding local regulations.1.15 Earthing of the objectThe object to be coated must be earthed.(Building walls are usually earthed naturally)1.16 Cleaning the unit with solventsWhen cleaning the unit with solvents, thesolvent should never be sprayed or pumpedback into a container with a small opening(bunghole). An explosive gas/air mixture canarise. The container must be earthed.1.17 Cleaning the unitDanger of short-circuits caused by water ingression!Never spray down the unit with high-pressureor high-pressure steam cleaners.1.11 Electrostatic charging (formation ofsparks or flames)Electrostatic charging of the unit may occurduring spraying due to the flow speed ofthe coating material. These can cause sparksand flames upon discharge. The unit musttherefore always be earthed via the electricalsystem. The unit must be connected to anappropriately-grounded safety outlet.1.18 Work or repairs at the electricalequipmentThese may only be carried out by a skilled electrician. No liabilityis assumed for incorrect installation.1.19 Work at electrical componentsUnplug the power plug from the outlet before carrying outany repair work.1.12 Use of units on building sites andworkshopsThe unit may only be connected to the mains network via aspecial feeding point with a residual-current device with INF≤ 30 mA.1.13 Ventilation when spraying in roomsAdequate ventilation to ensure removal of the solvent vaporshas to be ensured.34

Hurra! Ihre Datei wurde hochgeladen und ist bereit für die Veröffentlichung.

Erfolgreich gespeichert!

Leider ist etwas schief gelaufen!